13. HEAVY BASE WEIGHT<br />

DESCRIPTION:<br />

Base weight above required weight, poor base clearance may be evident. Thin<br />

shoulder or body may cause poor topload.<br />

CAUSE:<br />

1. Pre-blow pressure too low.<br />

2. Pre-blow cam too late.<br />

3. Poor heating profile resulting in poor distribution of material.<br />

4. If only one station is affected then flow restrictor may be closed<br />

too many turns.<br />

SOLUTION:<br />

1. Increase pre-blow pressure.<br />

2. Move pre-blow cam earlier.<br />

3. Adjust heating profile.<br />

4. If only one station is affected then open flow restrictor to increase flow of<br />

pre-blow air.