27. DROP TEST FAILURES<br />

DESCRIPTION/FAULT:<br />

Bottles burst open in the base when drop test is carried out.<br />

CAUSE:<br />

1. Preform end cap blown too cold.<br />

2. Heavy base weight (unorientated material).<br />

3. Excessive crystallinity in preform base.<br />

4. Low IV.<br />

5. Poor base design – sharp edges between feet and at the punt.<br />

SOLUTION:<br />

1. Increasing heat at the gate or below without losing base weight usually<br />

improves drop test failure.<br />

2. Reduce base weight if above specification.<br />

3. Review base design.