3. Compute the length <strong>of</strong> the cable<br />

When d/L is 1/20 or less, the cable length can be approximated from S L 8d 2 /(3L),<br />

where S cable length, ft (m). Thus, S 960 8(50) 2 /[3(960)] 966.94 ft (294.72 m).<br />

CATENARY CABLE SAG AND DISTANCE<br />

BETWEEN SUPPORTS<br />

A cable 500 ft (152.4 m) long and weighing 3 pounds per linear foot (lb/lin ft) (43.8<br />

N/m) is supported at two points lying in the same horizontal plane. If the tension at the<br />

supports is 1800 lb (8006 N), find the sag <strong>of</strong> the cable and the distance between the<br />

supports.<br />

Calculation Procedure:<br />

1. Compute the catenary parameter<br />

A cable <strong>of</strong> uniform cross section carrying only its own weight assumes the form <strong>of</strong> a catenary.<br />

Using the notation <strong>of</strong> the previous procedure, we find the catenary parameter c from<br />

d c T/w 1800/3 600 ft (182.9 m). Then c [(d c) 2 (S/2) 2 ] 0.5 [(600) 2 ] 0.5<br />

(250) 2 ] 0.5 545.4 ft (166.2 m).<br />

2. Compute the cable sag<br />

Since d c 600 ft (182.9 m) and c 545.4 ft (166.2 m), we know d 600 545.4 <br />

54.6 ft (l6.6 m).<br />

3. Compute the span length<br />

Use the relation L 2c ln (d c 0.5S)/c, or L 2(545.5) ln (600 250) 545.4 <br />

484.3 ft (147.6 m).<br />

STABILITY OF A RETAINING WALL<br />

Determine the factor <strong>of</strong> safety (FS) against sliding and overturning <strong>of</strong> the concrete retaining<br />

wall in Fig. 10. The concrete weighs 150 lb/ft 3 (23.56 kN/m 3 , the earth weighs 100 lb/ft 3<br />

(15.71 kN/m 3 ), the coefficient <strong>of</strong> friction is 0.6, and the coefficient <strong>of</strong> active earth pressure<br />

is 0.333.<br />

Calculation Procedure:<br />

STATICS, STRESS AND STRAIN, AND FLEXURAL ANALYSIS<br />

1. Compute the vertical loads on the wall<br />

Select a 1-ft (304.8-mm) length <strong>of</strong> wall as typical <strong>of</strong> the entire structure. The horizontal<br />

pressure <strong>of</strong> the confined soil varies linearly with the depth and is represented by the triangle<br />

BGF in Fig. 10<br />

Resolve the wall into the elements AECD and AEB; pass the vertical plane BF through<br />

the soil. Calculate the vertical loads, and locate their resultants with respect to the toe C.<br />

Thus W 1 15(1)(150) 2250 lb (10,008 N); W 2 0.5(15)(5)(150) 5625; W 3 <br />

0.5(15)(5)(100) 3750. Then W 11,625 lb (51,708 N). Also, x 1 0.5 ft; x 2 1 <br />

0333(5) 2.67 ft (0.81 m); x 3 1 0.667(5) 433 ft (1.32 m).<br />

1.17