Part 1: General Requirements<br />

1.01 Description of Work<br />

A. Furnish and install metal roofing (fascia and/or<br />

mansard) and accessories in accordance with<br />

<strong>Petersen</strong> <strong>Aluminum</strong> Corporation specifications and<br />

all applicable drawings. Roof support (structural)<br />

systems and counterflashings are not included in<br />

the section.<br />

1.02 Products<br />

Metal roofing (Fascia and /or mansard) shall be as<br />

manufactured by <strong>Petersen</strong> <strong>Aluminum</strong> Corporation and<br />

shall consist of one of the following profiles:<br />

A. Integral Batten Panel (11”, 18” or 19” O.C.)<br />

B. Integral Standing Seam Panel (11”, 16”, 18” or<br />

19” O.C.)<br />

C. SNAP-<strong>CLAD</strong> (10”, 12”, 16” or 18” O.C.)<br />

D. Snap-on Batten (11”, 12”, 18” O.C.)<br />

E. Snap-on Standing Seam (12”, 18”, 19” or 20”<br />

O.C.)<br />

F. High Snap-on Standing Seam (11”, 18” or 19”<br />

O.C.)<br />

G. Flush Panel (7”, 11” or 18” O.C.)<br />

H. Reveal Panel (7”, 11” or 18” O.C.)<br />

I. Redi-Roof Standing Seam (12” or 18” O.C.)<br />

J. Redi-Roof Batten (12” O.C.)<br />

K. M & R Panels (41” & 42” widths)<br />

L. Tite-Loc Panels (12”, 16” or 18” O.C.)<br />

1.03 Submittals<br />

A. Submit manufacturer’s current specifications and<br />

related literature.<br />

B. Provide samples in accordance with section<br />

C. Submit shop drawing as required outlining roof<br />

plans, profiles, forming details, trim flashings.<br />

Show details of weather-proofing at all edges and<br />

penetrations.<br />

D. Submit manufacturer’s 20 year paint warranty<br />

covering finish fade, chalk and peel (<strong>PAC</strong>-<strong>CLAD</strong>).<br />

Part 2: Products<br />

2.01 Manufacturer<br />

<strong>Petersen</strong> <strong>Aluminum</strong> Corporation<br />

2.02 Materials<br />

Please refer to the individual specifications for each<br />

panel listed in the <strong>catalog</strong> to properly complete this section.<br />

A. Profile<br />

B. Gauge and grade of sub-strata material.<br />

1. 24 ga. G-90 galvanized steel<br />

2. 22 ga. G-90 galvanized steel<br />

(limited profiles)<br />

3. .032 ga aluminum<br />

4. .040 ga aluminum<br />

(limited profiles)<br />

5. 16 oz. cold rolled copper<br />

(limited profiles)<br />

C. Finish<br />

1. <strong>PAC</strong>-<strong>CLAD</strong> ®<br />

2. <strong>PAC</strong> 500 Bronze anodized<br />

3. <strong>PAC</strong> 300 Clear anodized<br />

D. On Center Dimension<br />

E. Sheet Metal Flashing and Trim: shall be fabricated<br />

from same materials and finish as panels.<br />

F. Fasteners: shall be provided by manufacturer as<br />

required.<br />

07 61 00/PET<br />

BuyLine 3008<br />

2.03 Color<br />

Color shall be as selected for <strong>PAC</strong>-<strong>CLAD</strong> standard color<br />

chart (or custom color as selected by architect: please<br />

consult with manufacturer).<br />

Part 3: Delivery and Execution<br />

3.01 Delivery<br />

A. Suitable facilities for storage and protection of<br />

materials shall be provided by the contractor on the<br />

site.<br />

B. Upon receipt of materials, installer shall inspect the<br />

shipment for damage and to insure shipment is<br />

complete.<br />

3.02 Installation<br />

A. All surfaces on which the work is to be applied shall<br />

be examined for flatness as appropriate to<br />

application.<br />

B. Panels shall be installed so that horizontal lines are<br />

level and vertical lines are even.<br />

C. All sheet metal work shall conform to standards set<br />

forth in the SMACNA architectural sheet metal<br />

manual.<br />

D. Fasteners shall be concealed as pro-vided by<br />

manufacturer.<br />

3.03 Touch-up<br />

Only minor scratches and abrasions shall be allowed to<br />

be touched up. Any other damaged materials shall be<br />

replaced.<br />

3.04 Clean-up<br />

Leave work areas clean and remove all scrap and debris<br />

from surrounding area.<br />

A complete specification is available online at<br />

www.pac-clad.com<br />

Calvary Church<br />

Naperville, IL<br />

Owner: Calvary Church<br />

General Contractor: Paul H. Schwendener<br />

Roofing Contractor: James Mansfield & Sons., Inc. and<br />

A-1 Roofing<br />

Profile: Snap-Clad & Flat Seam Panels<br />

Color: Musket Gray Kynar & TCS II 23