- Page 1:
Front cover IBM Power 720 and 740 T
- Page 4 and 5:
Note: Before using this information
- Page 6 and 7:
1.13.8 Rack-mounting rules . . . .
- Page 8 and 9:
4.3.5 Locating and servicing . . .
- Page 10 and 11:
Trademarks IBM, the IBM logo, and i
- Page 12 and 13:
is also skilled on IBM System Stora
- Page 14 and 15:
► Explore new Redbooks publicatio
- Page 16 and 17:
1.1 Systems overview You can find d
- Page 18 and 19:
The Power 740 server supports a max
- Page 20 and 21:
1.3 Physical package 1.3.1 Tower mo
- Page 22 and 23:
► Choice of two disk/media backpl
- Page 24 and 25:
1.4.6 Memory features Table 1-6 sum
- Page 26 and 27:
Feature code Description OS support
- Page 28 and 29:
Certain adapters are available for
- Page 30 and 31:
Table 1-13 shows the available medi
- Page 32 and 33:
Table 1-14 summarizes the maximum n
- Page 34 and 35:
Consider these minimum definitions
- Page 36 and 37:
These are the requirements to be el
- Page 38 and 39: Console (SDMC) is required to manag
- Page 40 and 41: 1.13.3 IBM 7014 Model T42 rack The
- Page 42 and 43: applications by varying the PDU-to-
- Page 44 and 45: 1.13.10 OEM rack ► One tape drive
- Page 46 and 47: ► The vertical distance between t
- Page 48 and 49: DIMM #1 DIMM #3 DIMM #5 DIMM #7 Fig
- Page 50 and 51: 2.1 The IBM POWER7 processor The IB
- Page 52 and 53: Table 2-1 summarizes the technology
- Page 54 and 55: 2.1.4 Memory access Each POWER7 pro
- Page 56 and 57: 2.1.6 On-chip L3 cache innovation a
- Page 58 and 59: 2.2 POWER7 processor modules The Po
- Page 60 and 61: Feature Cores per POWER7 processor
- Page 62 and 63: MC0 Port 0 MC0 Port 1 POWER7 MC0 Po
- Page 64 and 65: 2.3.3 Memory bandwidth The POWER7 p
- Page 66 and 67: 2.7.1 Slot configuration Table 2-10
- Page 68 and 69: The Power 720 and Power 740 system
- Page 70 and 71: 2.8.3 LAN adapters Table 2-12 shows
- Page 72 and 73: Table 2-14 Available SCSI and SAS a
- Page 74 and 75: 2.8.7 iSCSI a. Only supported in th
- Page 76 and 77: Ethernet and Fibre Channel Cables F
- Page 78 and 79: 2.8.11 Asynchronous adapters Asynch
- Page 80 and 81: 2.9.1 RAID support There are multip
- Page 82 and 83: 2.9.3 Media bays Figure 2-17 detail
- Page 84 and 85: Figure 2-18 shows the back view of
- Page 86 and 87: Note: Mode change using the physica
- Page 90 and 91: The configuration rules are the sam
- Page 92 and 93: ► IBM 7031 TotalStorage EXP24 Ult
- Page 94 and 95: Feature code Description OS support
- Page 96 and 97: Include EXP24S no-charge specify co
- Page 98 and 99: Note: A new IBM 7031 TotalStorage E
- Page 100 and 101: Type-model Availability Description
- Page 102 and 103: Figure 2-30 shows a simple network
- Page 104 and 105: Figure 2-31 shows one possible high
- Page 106 and 107: The SDMC can be obtained as a hardw
- Page 108 and 109: IBM periodically releases maintenan
- Page 110 and 111: processors, through to the POWER4+,
- Page 112 and 113: When a system is idle, the system f
- Page 114 and 115: A new power savings mode called Inh
- Page 116 and 117: 3.1 POWER Hypervisor Combined with
- Page 118 and 119: Virtual Fibre Channel A virtual Fib
- Page 120 and 121: Table 3-2 lists the differences bet
- Page 122 and 123: To help you perform this study, a p
- Page 124 and 125: 3.4 PowerVM From the HMC, you can s
- Page 126 and 127: Micro-Partitioning Micro-Partitioni
- Page 128 and 129: Dedicated mode In dedicated mode, p
- Page 130 and 131: Default Shared Processor Pool (SPP
- Page 132 and 133: Important: Level 1 capacity resolut
- Page 134 and 135: The Virtual Fibre Channel adapter i
- Page 136 and 137: Figure 3-12 shows an example where
- Page 138 and 139:
Source and destination system requi
- Page 140 and 141:
3.4.7 Active Memory Deduplication I
- Page 142 and 143:
Figure 3-15 shows two pages being w
- Page 144 and 145:
NPIV is supported in PowerVM Expres
- Page 146 and 147:
Features Linux releases Comments Fo
- Page 148 and 149:
134 IBM Power 720 and 740 Technical
- Page 150 and 151:
4.1 Reliability Highly reliable sys
- Page 152 and 153:
Throughout this chapter we describe
- Page 154 and 155:
4.2.3 Memory protection A memory pr
- Page 156 and 157:
POWER Hypervisor. This deallocation
- Page 158 and 159:
failing components to be replaced b
- Page 160 and 161:
problems so that the system adminis
- Page 162 and 163:
► Concurrent access to the servic
- Page 164 and 165:
4.3.3 Reporting Boot time When an I
- Page 166 and 167:
4.3.4 Notifying When a local or glo
- Page 168 and 169:
Packaging for service These service
- Page 170 and 171:
Upgrading to a higher Release Level
- Page 172 and 173:
machine-wide settings by using the
- Page 174 and 175:
The operator panel can be accessed
- Page 176 and 177:
Depending on the operating system,
- Page 178 and 179:
If there is an HMC to manage the se
- Page 180 and 181:
4.5 Operating system support for RA
- Page 182 and 183:
RAS feature AIX 5.3 Redundant HMCs
- Page 184 and 185:
Other publications These publicatio
- Page 186:
172 IBM Power 720 and 740 Technical