19. Broadcast Cables - Belden
19. Broadcast Cables - Belden
19. Broadcast Cables - Belden
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
B R I L L I A N C E ® B R O A D C A S T C A B L E S <strong>19.</strong>66<br />
Composite Camera Cable<br />
Audio and Video, ENG and EFP <strong>Cables</strong><br />
Multiple Coax with Shielded Twisted Pairs<br />
Description<br />
Part<br />
No.<br />
UL NEC/<br />
C(UL) CEC<br />
Type<br />
Standard Lengths<br />
Ft. m<br />
Standard<br />
Unit Weight<br />
Lbs. kg<br />
12-conductor EFP and ENG Camera Cable<br />
Conductor<br />
(stranding)<br />
Diameter<br />
Nom. DCR<br />
Nominal<br />
Core OD<br />
Shielding<br />
Materials<br />
Nominal OD<br />
Inch mm Nom. DCR Inch mm<br />
Foam Polyethylene (Coax) and Polypropylene (Pairs) Insulation • Overall Chrome PVC Jacket<br />
Nom.<br />
Imp.<br />
(Ω)<br />
Nom.<br />
Vel.<br />
of<br />
Prop.<br />
Nominal<br />
Capacitance<br />
75°C 9170 — 1000 304.8 113.0 51.4 (2) Coax: .100 2.54 Each Coax: .490 12.45 75 78% 17.3 56.8<br />
VW-1 25 AWG Coax OD: TC<br />
(7x33) .150 3.81 Braid<br />
.022″ BC 93% Shield<br />
31.2Ω/M′ Coverage<br />
102.0Ω/km 6.0Ω/M′<br />
Black,<br />
Black with<br />
Hash Marks<br />
<strong>19.</strong>7Ω/km<br />
Z-Fold ®<br />
14-conductor EFP and ENG Camera Cable<br />
pF/Ft.<br />
pF/m<br />
(5) Pairs: .044 1.12 Each Pair: 66% 27.0 88.6<br />
24 AWG Pair OD: Beldfoil ®<br />
(7x32) .095 2.41 Shielded<br />
.024″ TC 100% Shield<br />
24.0Ω/M′ Coverage<br />
78.0Ω/km with 24 AWG<br />
Black & Red, Drain Wire<br />
Black & White, 18.0Ω/M′<br />
Black & Green, 59.1Ω/km<br />
Black & Blue,<br />
Black & Yellow<br />
Foam Polyethylene (Coax) and PVC (Pairs and Conductors) Insulation • Overall Chrome PVC Jacket<br />
75°C 9171 — 500 152.4 97.5 44.3 (2) Coax: .146 3.71 Each Coax: .585 14.86 75 78% 17.3 56.8<br />
1000 304.8 193.0 87.7 22 AWG Coax OD: BC<br />
(7x30) .242 6.15 Braid<br />
.030″ BC 95% Shield<br />
15.0Ω/M′ Coverage<br />
49.2Ω/km 2.5Ω/M′<br />
Black, 8.6Ω/km<br />
Black with<br />
Hash Marks<br />
Z-Fold ®<br />
(5) Pairs: .054 1.37 Each Pair: 51.0 167.3<br />
22 AWG Pair OD: Beldfoil<br />
(7x30) .110 2.79 Shielded<br />
.030″ TC 100% Shield<br />
15.0Ω/M′ Coverage<br />
49.2Ω/km with 22 AWG<br />
Black & Red, Drain Wire<br />
Black & White, 11.6Ω/M′<br />
Black & Green, 38.0Ω/km<br />
Black & Blue,<br />
Black & Yellow<br />
(2) Cond: Each Cond. OD:<br />
16 AWG<br />
(26x30)<br />
.060″ TC<br />
4.0Ω/M′<br />
13.1Ω/km<br />
Black, White<br />
.092 2.34<br />
BC = Bare Copper • DCR = DC Resistance • EFP = Electronic Field Production • ENG = Electronic News Gathering • TC = Tinned Copper<br />
Contact the <strong>Belden</strong> Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. Request quotations of cables not listed.<br />
MHz<br />
dB/<br />
100 Ft. dB/<br />
Nominal<br />
Attenuation<br />
100m<br />
1 .4 1.3<br />
10 1.5 4.9<br />
50 3.8 12.5<br />
100 5.6 18.4<br />
300 10.6 34.8<br />
500 13.8 45.3<br />
1 .3 1.0<br />
2 .6 2.0<br />
10 1.0 3.3<br />
50 2.3 7.5<br />
100 3.2 10.5<br />
For more information, contact <strong>Belden</strong> Technical Support: 1-800-BELDEN-1 • www.belden.com