Surfix C<br />
Surfix C is a conventional grade cationic<br />
bitumen emulsion for surface dressing.<br />
By using selected emulsifying agents with a<br />
suitable emulsion grade penetration bitumen<br />
it has been specifically designed for use as a<br />
hot applied surface dressing binder.<br />
Being an emulsion of bitumen in water, Surfix C,<br />
when compared with the traditional anhydrous<br />
binders has the following advantages:<br />
• It is applied at the lower, therefore safer<br />
temperature range of 80º to 90ºC<br />
• There is a negligible fire risk and the hazards<br />
of fuming are minimal<br />
• The wetting and adhesion to chippings and<br />
road surfaces is excellent<br />
• It is more tolerant to dusty chippings and<br />
lightly coated chippings are never required<br />
or indeed recommended<br />
• The higher residual viscosity in the early life<br />
of the dressing provides a greater resistance<br />
to traffic stresses<br />
• The stabilised dressing is less prone to<br />
flushing up in hot weather conditions<br />
• It is more ‘user-friendly’<br />
Surfix C is loaded into clean road tankers at or<br />
near the spraying temperature. Care must be<br />
www.colas.co.im<br />
taken during subsequent heating to ensure that<br />
the binder is thoroughly circulated and that the<br />
temperature does not exceed 90ºC. Above this<br />
temperature there is a danger of severe frothing<br />
which may result in spillage and possible noncompliance<br />
with the specification.<br />
Application<br />
Surfix C should be applied at the correct rate of<br />
spread to the road surface by calibrated spray<br />
tankers to conform to BS1707 (Hot Binder<br />
Distributors for Surface Dressing).<br />
The surface dressing works should be in<br />
accordance with the recommendations<br />
contained in Road Note 39 and the Road Surface<br />
Dressing Associations Code of Practice and<br />
Guidance Notes. As a guide, rates of spread are<br />
generally in agreement with Road Note 39,<br />
Chippings must be uncoated, of good quality,<br />
dust free and conforming to BS EN13043.’<br />
Standards<br />
Surfix C complies with BS EN 13808:2005 for<br />
C69B3 or C69BF3 (formerly K1-70 to BS 434 - 1).<br />
Safety<br />
For full safety information, please contact our<br />
stores office.<br />
Property Reference Surfix C<br />
Particle Charge BS 434 Part 1 Appendix C Positive<br />
Binder Content % m/m BS 434 Part 1 Appendix F 67 (min)<br />
Viscosity Redwood II at 85ºC secs<br />
Lower viscosity available by specific requests.<br />
BS 434 Part 1 Appendix G2 25-35<br />
27