CAPIOX ® FX Oxygenators with Integrated Arterial Filter<br />
<strong>Patients</strong> <strong>come</strong> <strong>in</strong> a range of sizes.<br />
<strong>Now</strong> <strong>your</strong> <strong>oxygenator</strong> <strong>does</strong>, <strong>too</strong>.
Meet<strong>in</strong>g the needs of<br />
all <strong>your</strong> patients<br />
Family of Oxygenators<br />
Prescriptive Oxygenation TM is <strong>Terumo</strong>’s unique approach to help<strong>in</strong>g you meet each patient’s oxygenation<br />
and blood management needs more precisely, with the freedom to choose the right size<br />
CAPIOX ® <strong>oxygenator</strong>.<br />
<strong>Patients</strong> of different sizes have different oxygenation and blood management needs – therefore no one<br />
size <strong>oxygenator</strong> fits all patients. In fact, research shows that smaller patients face <strong>in</strong>creased mortality rates<br />
and may have less favorable out<strong>come</strong>s after cardiac surgery due to greater <strong>in</strong>cidence of transfusion. 1,2<br />
<strong>Terumo</strong>’s unique Prescriptive Oxygenation approach is part of the solution for every patient population.<br />
As a perfusionist, assess<strong>in</strong>g patients’ oxygenation needs is a choice you make every day. <strong>Now</strong>,<br />
you can choose the right <strong>oxygenator</strong> for every patient, of any size. Only <strong>Terumo</strong> offers a full l<strong>in</strong>e of<br />
proven low prime volume <strong>oxygenator</strong> solutions.<br />
• The right size <strong>oxygenator</strong> can make a difference toward better patient out<strong>come</strong>s.<br />
• Studies show that controll<strong>in</strong>g hemodilution through lower prime volume circuits can result <strong>in</strong><br />
fewer blood transfusions. 1,2,3<br />
CAPIOX ® FX15 Oxygenator<br />
FX15: Designed for children, and small and mid-sized adults.<br />
With the FX15 <strong>oxygenator</strong> you can significantly<br />
lower prime volume for a group of patients that<br />
tend to have a higher rate of blood transfusions.<br />
<strong>Now</strong> <strong>your</strong> smaller patients can have surgery<br />
with an <strong>oxygenator</strong> that best fits their unique<br />
metabolic needs, which may help m<strong>in</strong>imize the<br />
need for a blood transfusion. Available <strong>in</strong> two<br />
reservoir sizes.<br />
FX15R30 Specifications:<br />
Prime 144mL, Maximum Flow 4,0L/m<strong>in</strong>.,<br />
Integrated Arterial Filter Surface Area 360 cm 2<br />
FX15R40 Specifications:<br />
Prime 144mL, Maximum Flow 5,0L/m<strong>in</strong>.,<br />
Integrated Arterial Filter Surface Area 360 cm 2<br />
The CAPIOX ® FX15 Oxygenator addresses the<br />
needs of a large segment of the patient population.<br />
Based on their body surface area, a significant<br />
number of patients would benefit from a<br />
smaller or mid-sized <strong>oxygenator</strong> designed to better<br />
match their actual metabolic needs while decreas<strong>in</strong>g<br />
hemodilution and other risks associated<br />
with cardiopulmonary bypass.<br />
Studies show that controll<strong>in</strong>g hemodilution<br />
through lower prime circuits can result <strong>in</strong> fewer<br />
blood transfusions. 1,2,3 The right size <strong>oxygenator</strong><br />
can make a difference towards m<strong>in</strong>imiz<strong>in</strong>g the<br />
need for transfusions.<br />
To learn more about Prescriptive Oxygenation<br />
and the full range of CAPIOX ® FX solutions, visit:<br />
www.terumo-cvs.com/FXfits<br />
Citations:<br />
1 Shann et al, An evidence-based<br />
review of the practice of cardiopulmonary<br />
bypass <strong>in</strong> adults: A<br />
focus on neurologic <strong>in</strong>jury, glycemic<br />
control, hemodilution, and the<br />
<strong>in</strong>flammatory response; Journal<br />
of Thoracic and Cardiovascular<br />
Surgery, 2006;132:283-290.<br />
2 Ferraris et al, 2011 Update to the<br />
Society of Thoracic Surgeons and<br />
the Society of Cardiovascular Anesthesiologists<br />
Blood Conservation<br />
Cl<strong>in</strong>ical Practice Guidel<strong>in</strong>es;<br />
Annals Thoracic Surgery, 2011;<br />
91: 944-982.<br />
3 Preston et al, Cl<strong>in</strong>ical Gaseous<br />
Microemboli Assessment of an<br />
Oxygenator with Integral Arterial<br />
Filter <strong>in</strong> the Pediatric Population,<br />
Journal of ExtraCorporeal Technology,<br />
2009; 41:226-230.
CAPIOX ® FX05 Oxygenator<br />
FX05: Designed for neonates and <strong>in</strong>fants.<br />
The FX05 <strong>oxygenator</strong> with <strong>in</strong>tegrated arterial filter<br />
offers low prime volume and high performance<br />
so you don’t have to choose one over the other<br />
for <strong>your</strong> smallest patients. Your most delicate patients<br />
deserve the smallest prime volume atta<strong>in</strong>able,<br />
and <strong>Terumo</strong> makes it possible.<br />
FX05 Specifications:<br />
Prime 43mL, Maximum Flow 1,5L/m<strong>in</strong>.,<br />
Integrated Arterial Filter Surface Area 130 cm 2<br />
Oxygenator FX05 FX15 FX25<br />
Fiber bundle<br />
surface area<br />
Approx. 0,5m2 Approx. 1,5m2 Approx. 2,5m2 Heat exchanger<br />
surface area<br />
Approx. 0,035m2 Approx. 0,14m2 Approx. 0,2m2 0,5 - 5,0L/m<strong>in</strong>;<br />
Blood flow range 0,1 - 1,5L/m<strong>in</strong> 0,5 - 4,0L/m<strong>in</strong><br />
(with R30)<br />
Reference blood<br />
flow (AAMI std.)<br />
2,5L/m<strong>in</strong> 7,0L/m<strong>in</strong> n.a.<br />
Prim<strong>in</strong>g volume<br />
(static)<br />
43mL 144mL 260mL<br />
Blood <strong>in</strong>let port<br />
(from pump)<br />
1/4“ (6,4mm) 3/8“ (9,5mm)<br />
Blood outlet port 1/4“ (6,4mm) 3/8“ (9,5mm)<br />
Cardioplegia port - 1/4“ (6,4mm)<br />
Luer port (for<br />
recirc. or blood<br />
cardioplegia)<br />
One luer lock on<br />
blood outlet port<br />
n.a.<br />
Gas <strong>in</strong>let port 1/4“ (6,4mm)<br />
Gas outlet port 5/16“ (7,9mm) 1/4“ (6,4mm)<br />
Water ports 1/2“ (12,7mm) Hansen quick-connect fitt<strong>in</strong>gs<br />
Maximum pressure<br />
Blood <strong>in</strong>let<br />
1000mmHg (133kPa)<br />
Maximum pressure<br />
Water <strong>in</strong>let<br />
2kgf/cm2 Material<br />
(196kPa) (28,5psi)<br />
Hous<strong>in</strong>g Polycarbonate<br />
Fibers Microporous polypropylene<br />
Heat exchanger<br />
Arterial filter<br />
Sta<strong>in</strong>less steel<br />
Filter material Polyester screen type<br />
Pore size 32µm<br />
Surface area 130cm2 360cm2 600cm2 CAPIOX ® FX25 Oxygenator<br />
Oxygenator Specifications Hardshell Reservoir Specifications<br />
The unique design of the FX25 <strong>oxygenator</strong> allows<br />
for reduced prime volume with the right fit<br />
for adults with a higher metabolic demand. You’ll<br />
appreciate that a full size <strong>oxygenator</strong> <strong>does</strong>n’t<br />
have to be high prime volume.<br />
FX25 Specifications:<br />
Prime 260mL, Maximum Flow 7,0L/m<strong>in</strong>.,<br />
Integrated Arterial Filter Surface Area 600cm 2<br />
FX25: Designed for all adults.<br />
Hardshell reservoir FX05 R30 (for FX15) R40 (for FX15) FX25<br />
Blood flow range<br />
Venous flow<br />
Cardiotomy <strong>in</strong>let<br />
Comb<strong>in</strong>ed flow<br />
0,1 - 1,5L/m<strong>in</strong><br />
Max. 1,5L/m<strong>in</strong><br />
Max. 1,5L/m<strong>in</strong><br />
0,5 - 4,0L/m<strong>in</strong><br />
Max. 4,0L/m<strong>in</strong><br />
Max. 4,0L/m<strong>in</strong><br />
0,5 - 5,0L/m<strong>in</strong><br />
Max. 5,0L/m<strong>in</strong><br />
Max. 5,0L/m<strong>in</strong><br />
0,5 - 7,0L/m<strong>in</strong><br />
Max. 5,0L/m<strong>in</strong><br />
Max. 7,0L/m<strong>in</strong><br />
Blood storage capacity 1000mL 3000mL 4000mL 4000mL<br />
M<strong>in</strong>. operat<strong>in</strong>g volume 15mL 70mL 200mL 200mL<br />
Venous blood <strong>in</strong>let port<br />
1/4“ (6,4mm)<br />
rotatable<br />
3/8“ (9,5mm)<br />
rotatable<br />
Blood outlet port (to pump) 1/4“ (6,4mm) 3/8“ (9,5mm)<br />
Suction ports<br />
Five 3/16“<br />
- 1/4“ (4,8mm -<br />
6,4mm) rotatable<br />
Six 1/4“ (6,4mm)<br />
Vertical port (to CR filter) n.a. 3/8“ (9,5mm)<br />
Quick prime port 1/4“ (6,4mm)<br />
Vent port 1/4“ (6,4mm)<br />
Auxiliary port 1/4“ - 3/8“ (6,4mm - 9,5mm)<br />
Luer ports<br />
Maximum susta<strong>in</strong>able negative<br />
pressure <strong>in</strong> reservoir<br />
Material<br />
1/2“ (12,7mm)<br />
rotatable<br />
1/2“ (12,7mm)<br />
rotatable<br />
Three filtered luer locks to cardiotomy filter, one non-filtered luer lock, two luer<br />
locks on venous <strong>in</strong>let<br />
-150mmHg (-20kPa)<br />
Hous<strong>in</strong>g Polycarbonate<br />
Venous filter Polyester screen type, Pore size 47µm<br />
Cardiotomy filter Polyester depth type<br />
Defoamer Polyurethane foam
Order<strong>in</strong>g Information<br />
Description Catalog no. Units/Case<br />
CAPIOX ® FX05 Oxygenator<br />
Oxygenator with <strong>in</strong>tegrated arterial filter 1 ....................................... CX*FX05W..................... 4<br />
Oxygenator with <strong>in</strong>tegrated arterial filter 1 ........................................ CX*FX05E..................... 4<br />
Oxygenator with <strong>in</strong>tegrated arterial filter/hardshell reservoir 2 .......CX*FX05RW..................... 4<br />
Oxygenator with <strong>in</strong>tegrated arterial filter/hardshell reservoir 2 ........CX*FX05RE..................... 4<br />
CAPIOX ® FX15 Oxygenator<br />
Oxygenator with <strong>in</strong>tegrated arterial filter 3 ....................................... CX*FX15W..................... 4<br />
Oxygenator with <strong>in</strong>tegrated arterial filter 3 ........................................ CX*FX15E..................... 4<br />
Oxygenator with <strong>in</strong>tegrated arterial filter/<br />
hardshell reservoir 4 ..................................................................CX*FX15RW30..................... 2<br />
Oxygenator with <strong>in</strong>tegrated arterial filter/<br />
hardshell reservoir 4 ...................................................................CX*FX15RE30..................... 2<br />
Oxygenator with <strong>in</strong>tegrated arterial filter/<br />
hardshell reservoir ...................................................................CX*FX15RW40..................... 2<br />
Oxygenator with <strong>in</strong>tegrated arterial filter/<br />
hardshell reservoir ....................................................................CX*FX15RE40..................... 2<br />
CAPIOX ® FX25 Oxygenator<br />
Oxygenator with <strong>in</strong>tegrated arterial filter ........................................ CX*FX25W..................... 4<br />
Oxygenator with <strong>in</strong>tegrated arterial filter ......................................... CX*FX25E..................... 4<br />
Oxygenator with <strong>in</strong>tegrated arterial filter/hardshell reservoir ........CX*FX25RW..................... 2<br />
Oxygenator with <strong>in</strong>tegrated arterial filter/hardshell reservoir .........CX*FX25RE..................... 2<br />
www.terumo-europe.com<br />
<strong>Terumo</strong> Corporation<br />
44-1, 2-chome, Hatagaya<br />
Shibuya-ku, Tokyo 151-0072,<br />
Japan<br />
Tel.: +81 3 3374 8111<br />
Fax: +81 3 3374 8196<br />
<strong>Europe</strong>an Headquarters<br />
<strong>Terumo</strong> <strong>Europe</strong> n.v.<br />
Interleuvenlaan 40<br />
3001 Leuven, Belgium<br />
Tel.: +32 16 38 12 11<br />
Fax: +32 16 40 02 49<br />
<strong>Europe</strong>an Offices<br />
<strong>Terumo</strong> <strong>Europe</strong> n.v.<br />
Benelux Sales Division<br />
Interleuvenlaan 40<br />
3001 Leuven, Belgium<br />
Tel.: +32 16 39 25 80<br />
Fax: +32 16 39 25 99<br />
The Netherlands:<br />
Tel.: 0800 0220396<br />
Fax: 0800 0220414<br />
Laboratoires <strong>Terumo</strong> France S.A.<br />
Parc Ariane - Bât. Uranus<br />
1, rue Hélène Boucher<br />
78284 Guyancourt Cedex, France<br />
Tel.: +33 130 96 13 00<br />
Fax: +33 130 43 60 85<br />
<strong>Terumo</strong> Deutschland GmbH<br />
Ludwig-Erhard-Strasse 6<br />
65760 Eschborn, Germany<br />
Tel.: +49 6196 80 230<br />
Fax: +49 6196 80 23 200<br />
<strong>Terumo</strong> Deutschland GmbH<br />
Zweigniederlassung Spreitenbach<br />
Bodenäckerstrasse 3<br />
8957 Spreitenbach, Switzerland<br />
Tel.: +41 56 419 10 10<br />
Fax: +41 56 419 10 11<br />
<strong>Terumo</strong> <strong>Europe</strong> España SL<br />
Avda. Juan Carlos I, Nº 13 - 7ª Planta<br />
Edificio Torre La Garena<br />
28806 Alcalá de Henares (Madrid),<br />
Spa<strong>in</strong><br />
Tel.: +34 9021 01 298<br />
Fax: +34 9021 01 358<br />
Holders for CAPIOX ® FX Oxygenators<br />
Holder for FX05 <strong>oxygenator</strong> .............................................................XX*CXH05..................... 1<br />
Holder for FX05 <strong>oxygenator</strong> with hardshell reservoir .....................XX*CXH05R..................... 1<br />
Adapter for SX holder for FX05 ................................................... XX*CXH05AD..................... 1<br />
Holder for FX15/25 <strong>oxygenator</strong> with<br />
hardshell reservoir (short arm) ............................................................801139..................... 1<br />
Holder for FX15/25 <strong>oxygenator</strong> with<br />
hardshell reservoir (long arm) .............................................................801804..................... 1<br />
Holder for FX25 <strong>oxygenator</strong> (US only) ..................................................812613..................... 1<br />
Holder for FX15 <strong>oxygenator</strong> (US only) ..................................................812614..................... 1<br />
Holder for FX15/25 <strong>oxygenator</strong> .......................................................XX*CXH15..................... 1<br />
Holder for FX15/25 <strong>oxygenator</strong> when<br />
seperated from reservoir...............................................................XX*CXH25F..................... 1<br />
Holder for FX15/25 <strong>oxygenator</strong> with<br />
hardshell reservoir (<strong>Europe</strong> only) ...................................................XX*CXH18R..................... 1<br />
Holder for FX15/25 <strong>oxygenator</strong> with<br />
hardshell reservoir, short arm (<strong>Europe</strong> only) ....................................XX*XH032..................... 1<br />
1 Conta<strong>in</strong>s 2 adapters 3/16“ - 1/4“ and a recirculation l<strong>in</strong>e<br />
2 Conta<strong>in</strong>s 4 adapters 3/16“ - 1/4“, 1 adapter 1/4“ - 3/8“ and<br />
a recirculation l<strong>in</strong>e<br />
3 Conta<strong>in</strong>s 2 adapters 1/4“ - 3/8“<br />
4 Conta<strong>in</strong>s 4 adapters 1/4“ - 3/8“<br />
<strong>Terumo</strong> Italia S.r.l.<br />
Via Simone Mart<strong>in</strong>i, 143 / 145<br />
00142 Roma RM,<br />
Italy<br />
Tel.: +39 0651 96 14 20<br />
Fax: +39 0650 30 407<br />
<strong>Terumo</strong> Sweden AB<br />
Nya Varvet, Byggnad 90<br />
Sven Källfelts Gata 18<br />
426 71 Västra Frölunda,<br />
Sweden<br />
Tel.: +46 3174 85 880<br />
Fax: +46 3174 85 890<br />
<strong>Terumo</strong> Denmark<br />
Filial of <strong>Terumo</strong> Sweden AB<br />
Tel.: +45 7020 93 80<br />
Fax: +45 7020 94 80<br />
<strong>Terumo</strong> UK Ltd<br />
Tamesis<br />
The Causeway<br />
Egham, Surrey<br />
TW20 9AW, United K<strong>in</strong>gdom<br />
Tel.: +44 1784 476 200<br />
Fax: +44 1784 476 201<br />
<strong>Terumo</strong> <strong>Europe</strong> n.v.<br />
Moscow Representative Office<br />
BC Northern Tower<br />
13Fr., 10 Testovskaya Street<br />
Moscow 123317, Russia<br />
Tel.: + 7 495 988 4740<br />
Fax: + 7 495 988 4739<br />
Addresses subject to change,<br />
please consult our Website.<br />
® Registered Trademark<br />
Published by <strong>Terumo</strong> <strong>Europe</strong> N.V.<br />
CV134 GB-1011FK-II 0.5 (10.11)E