05.04.2013 Views

Now your oxygenator does, too. Patients come in a ... - Terumo Europe

Now your oxygenator does, too. Patients come in a ... - Terumo Europe

Now your oxygenator does, too. Patients come in a ... - Terumo Europe

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CAPIOX ® FX Oxygenators with Integrated Arterial Filter<br />

<strong>Patients</strong> <strong>come</strong> <strong>in</strong> a range of sizes.<br />

<strong>Now</strong> <strong>your</strong> <strong>oxygenator</strong> <strong>does</strong>, <strong>too</strong>.


Meet<strong>in</strong>g the needs of<br />

all <strong>your</strong> patients<br />

Family of Oxygenators<br />

Prescriptive Oxygenation TM is <strong>Terumo</strong>’s unique approach to help<strong>in</strong>g you meet each patient’s oxygenation<br />

and blood management needs more precisely, with the freedom to choose the right size<br />

CAPIOX ® <strong>oxygenator</strong>.<br />

<strong>Patients</strong> of different sizes have different oxygenation and blood management needs – therefore no one<br />

size <strong>oxygenator</strong> fits all patients. In fact, research shows that smaller patients face <strong>in</strong>creased mortality rates<br />

and may have less favorable out<strong>come</strong>s after cardiac surgery due to greater <strong>in</strong>cidence of transfusion. 1,2<br />

<strong>Terumo</strong>’s unique Prescriptive Oxygenation approach is part of the solution for every patient population.<br />

As a perfusionist, assess<strong>in</strong>g patients’ oxygenation needs is a choice you make every day. <strong>Now</strong>,<br />

you can choose the right <strong>oxygenator</strong> for every patient, of any size. Only <strong>Terumo</strong> offers a full l<strong>in</strong>e of<br />

proven low prime volume <strong>oxygenator</strong> solutions.<br />

• The right size <strong>oxygenator</strong> can make a difference toward better patient out<strong>come</strong>s.<br />

• Studies show that controll<strong>in</strong>g hemodilution through lower prime volume circuits can result <strong>in</strong><br />

fewer blood transfusions. 1,2,3<br />

CAPIOX ® FX15 Oxygenator<br />

FX15: Designed for children, and small and mid-sized adults.<br />

With the FX15 <strong>oxygenator</strong> you can significantly<br />

lower prime volume for a group of patients that<br />

tend to have a higher rate of blood transfusions.<br />

<strong>Now</strong> <strong>your</strong> smaller patients can have surgery<br />

with an <strong>oxygenator</strong> that best fits their unique<br />

metabolic needs, which may help m<strong>in</strong>imize the<br />

need for a blood transfusion. Available <strong>in</strong> two<br />

reservoir sizes.<br />

FX15R30 Specifications:<br />

Prime 144mL, Maximum Flow 4,0L/m<strong>in</strong>.,<br />

Integrated Arterial Filter Surface Area 360 cm 2<br />

FX15R40 Specifications:<br />

Prime 144mL, Maximum Flow 5,0L/m<strong>in</strong>.,<br />

Integrated Arterial Filter Surface Area 360 cm 2<br />

The CAPIOX ® FX15 Oxygenator addresses the<br />

needs of a large segment of the patient population.<br />

Based on their body surface area, a significant<br />

number of patients would benefit from a<br />

smaller or mid-sized <strong>oxygenator</strong> designed to better<br />

match their actual metabolic needs while decreas<strong>in</strong>g<br />

hemodilution and other risks associated<br />

with cardiopulmonary bypass.<br />

Studies show that controll<strong>in</strong>g hemodilution<br />

through lower prime circuits can result <strong>in</strong> fewer<br />

blood transfusions. 1,2,3 The right size <strong>oxygenator</strong><br />

can make a difference towards m<strong>in</strong>imiz<strong>in</strong>g the<br />

need for transfusions.<br />

To learn more about Prescriptive Oxygenation<br />

and the full range of CAPIOX ® FX solutions, visit:<br />

www.terumo-cvs.com/FXfits<br />

Citations:<br />

1 Shann et al, An evidence-based<br />

review of the practice of cardiopulmonary<br />

bypass <strong>in</strong> adults: A<br />

focus on neurologic <strong>in</strong>jury, glycemic<br />

control, hemodilution, and the<br />

<strong>in</strong>flammatory response; Journal<br />

of Thoracic and Cardiovascular<br />

Surgery, 2006;132:283-290.<br />

2 Ferraris et al, 2011 Update to the<br />

Society of Thoracic Surgeons and<br />

the Society of Cardiovascular Anesthesiologists<br />

Blood Conservation<br />

Cl<strong>in</strong>ical Practice Guidel<strong>in</strong>es;<br />

Annals Thoracic Surgery, 2011;<br />

91: 944-982.<br />

3 Preston et al, Cl<strong>in</strong>ical Gaseous<br />

Microemboli Assessment of an<br />

Oxygenator with Integral Arterial<br />

Filter <strong>in</strong> the Pediatric Population,<br />

Journal of ExtraCorporeal Technology,<br />

2009; 41:226-230.


CAPIOX ® FX05 Oxygenator<br />

FX05: Designed for neonates and <strong>in</strong>fants.<br />

The FX05 <strong>oxygenator</strong> with <strong>in</strong>tegrated arterial filter<br />

offers low prime volume and high performance<br />

so you don’t have to choose one over the other<br />

for <strong>your</strong> smallest patients. Your most delicate patients<br />

deserve the smallest prime volume atta<strong>in</strong>able,<br />

and <strong>Terumo</strong> makes it possible.<br />

FX05 Specifications:<br />

Prime 43mL, Maximum Flow 1,5L/m<strong>in</strong>.,<br />

Integrated Arterial Filter Surface Area 130 cm 2<br />

Oxygenator FX05 FX15 FX25<br />

Fiber bundle<br />

surface area<br />

Approx. 0,5m2 Approx. 1,5m2 Approx. 2,5m2 Heat exchanger<br />

surface area<br />

Approx. 0,035m2 Approx. 0,14m2 Approx. 0,2m2 0,5 - 5,0L/m<strong>in</strong>;<br />

Blood flow range 0,1 - 1,5L/m<strong>in</strong> 0,5 - 4,0L/m<strong>in</strong><br />

(with R30)<br />

Reference blood<br />

flow (AAMI std.)<br />

2,5L/m<strong>in</strong> 7,0L/m<strong>in</strong> n.a.<br />

Prim<strong>in</strong>g volume<br />

(static)<br />

43mL 144mL 260mL<br />

Blood <strong>in</strong>let port<br />

(from pump)<br />

1/4“ (6,4mm) 3/8“ (9,5mm)<br />

Blood outlet port 1/4“ (6,4mm) 3/8“ (9,5mm)<br />

Cardioplegia port - 1/4“ (6,4mm)<br />

Luer port (for<br />

recirc. or blood<br />

cardioplegia)<br />

One luer lock on<br />

blood outlet port<br />

n.a.<br />

Gas <strong>in</strong>let port 1/4“ (6,4mm)<br />

Gas outlet port 5/16“ (7,9mm) 1/4“ (6,4mm)<br />

Water ports 1/2“ (12,7mm) Hansen quick-connect fitt<strong>in</strong>gs<br />

Maximum pressure<br />

Blood <strong>in</strong>let<br />

1000mmHg (133kPa)<br />

Maximum pressure<br />

Water <strong>in</strong>let<br />

2kgf/cm2 Material<br />

(196kPa) (28,5psi)<br />

Hous<strong>in</strong>g Polycarbonate<br />

Fibers Microporous polypropylene<br />

Heat exchanger<br />

Arterial filter<br />

Sta<strong>in</strong>less steel<br />

Filter material Polyester screen type<br />

Pore size 32µm<br />

Surface area 130cm2 360cm2 600cm2 CAPIOX ® FX25 Oxygenator<br />

Oxygenator Specifications Hardshell Reservoir Specifications<br />

The unique design of the FX25 <strong>oxygenator</strong> allows<br />

for reduced prime volume with the right fit<br />

for adults with a higher metabolic demand. You’ll<br />

appreciate that a full size <strong>oxygenator</strong> <strong>does</strong>n’t<br />

have to be high prime volume.<br />

FX25 Specifications:<br />

Prime 260mL, Maximum Flow 7,0L/m<strong>in</strong>.,<br />

Integrated Arterial Filter Surface Area 600cm 2<br />

FX25: Designed for all adults.<br />

Hardshell reservoir FX05 R30 (for FX15) R40 (for FX15) FX25<br />

Blood flow range<br />

Venous flow<br />

Cardiotomy <strong>in</strong>let<br />

Comb<strong>in</strong>ed flow<br />

0,1 - 1,5L/m<strong>in</strong><br />

Max. 1,5L/m<strong>in</strong><br />

Max. 1,5L/m<strong>in</strong><br />

0,5 - 4,0L/m<strong>in</strong><br />

Max. 4,0L/m<strong>in</strong><br />

Max. 4,0L/m<strong>in</strong><br />

0,5 - 5,0L/m<strong>in</strong><br />

Max. 5,0L/m<strong>in</strong><br />

Max. 5,0L/m<strong>in</strong><br />

0,5 - 7,0L/m<strong>in</strong><br />

Max. 5,0L/m<strong>in</strong><br />

Max. 7,0L/m<strong>in</strong><br />

Blood storage capacity 1000mL 3000mL 4000mL 4000mL<br />

M<strong>in</strong>. operat<strong>in</strong>g volume 15mL 70mL 200mL 200mL<br />

Venous blood <strong>in</strong>let port<br />

1/4“ (6,4mm)<br />

rotatable<br />

3/8“ (9,5mm)<br />

rotatable<br />

Blood outlet port (to pump) 1/4“ (6,4mm) 3/8“ (9,5mm)<br />

Suction ports<br />

Five 3/16“<br />

- 1/4“ (4,8mm -<br />

6,4mm) rotatable<br />

Six 1/4“ (6,4mm)<br />

Vertical port (to CR filter) n.a. 3/8“ (9,5mm)<br />

Quick prime port 1/4“ (6,4mm)<br />

Vent port 1/4“ (6,4mm)<br />

Auxiliary port 1/4“ - 3/8“ (6,4mm - 9,5mm)<br />

Luer ports<br />

Maximum susta<strong>in</strong>able negative<br />

pressure <strong>in</strong> reservoir<br />

Material<br />

1/2“ (12,7mm)<br />

rotatable<br />

1/2“ (12,7mm)<br />

rotatable<br />

Three filtered luer locks to cardiotomy filter, one non-filtered luer lock, two luer<br />

locks on venous <strong>in</strong>let<br />

-150mmHg (-20kPa)<br />

Hous<strong>in</strong>g Polycarbonate<br />

Venous filter Polyester screen type, Pore size 47µm<br />

Cardiotomy filter Polyester depth type<br />

Defoamer Polyurethane foam


Order<strong>in</strong>g Information<br />

Description Catalog no. Units/Case<br />

CAPIOX ® FX05 Oxygenator<br />

Oxygenator with <strong>in</strong>tegrated arterial filter 1 ....................................... CX*FX05W..................... 4<br />

Oxygenator with <strong>in</strong>tegrated arterial filter 1 ........................................ CX*FX05E..................... 4<br />

Oxygenator with <strong>in</strong>tegrated arterial filter/hardshell reservoir 2 .......CX*FX05RW..................... 4<br />

Oxygenator with <strong>in</strong>tegrated arterial filter/hardshell reservoir 2 ........CX*FX05RE..................... 4<br />

CAPIOX ® FX15 Oxygenator<br />

Oxygenator with <strong>in</strong>tegrated arterial filter 3 ....................................... CX*FX15W..................... 4<br />

Oxygenator with <strong>in</strong>tegrated arterial filter 3 ........................................ CX*FX15E..................... 4<br />

Oxygenator with <strong>in</strong>tegrated arterial filter/<br />

hardshell reservoir 4 ..................................................................CX*FX15RW30..................... 2<br />

Oxygenator with <strong>in</strong>tegrated arterial filter/<br />

hardshell reservoir 4 ...................................................................CX*FX15RE30..................... 2<br />

Oxygenator with <strong>in</strong>tegrated arterial filter/<br />

hardshell reservoir ...................................................................CX*FX15RW40..................... 2<br />

Oxygenator with <strong>in</strong>tegrated arterial filter/<br />

hardshell reservoir ....................................................................CX*FX15RE40..................... 2<br />

CAPIOX ® FX25 Oxygenator<br />

Oxygenator with <strong>in</strong>tegrated arterial filter ........................................ CX*FX25W..................... 4<br />

Oxygenator with <strong>in</strong>tegrated arterial filter ......................................... CX*FX25E..................... 4<br />

Oxygenator with <strong>in</strong>tegrated arterial filter/hardshell reservoir ........CX*FX25RW..................... 2<br />

Oxygenator with <strong>in</strong>tegrated arterial filter/hardshell reservoir .........CX*FX25RE..................... 2<br />

www.terumo-europe.com<br />

<strong>Terumo</strong> Corporation<br />

44-1, 2-chome, Hatagaya<br />

Shibuya-ku, Tokyo 151-0072,<br />

Japan<br />

Tel.: +81 3 3374 8111<br />

Fax: +81 3 3374 8196<br />

<strong>Europe</strong>an Headquarters<br />

<strong>Terumo</strong> <strong>Europe</strong> n.v.<br />

Interleuvenlaan 40<br />

3001 Leuven, Belgium<br />

Tel.: +32 16 38 12 11<br />

Fax: +32 16 40 02 49<br />

<strong>Europe</strong>an Offices<br />

<strong>Terumo</strong> <strong>Europe</strong> n.v.<br />

Benelux Sales Division<br />

Interleuvenlaan 40<br />

3001 Leuven, Belgium<br />

Tel.: +32 16 39 25 80<br />

Fax: +32 16 39 25 99<br />

The Netherlands:<br />

Tel.: 0800 0220396<br />

Fax: 0800 0220414<br />

Laboratoires <strong>Terumo</strong> France S.A.<br />

Parc Ariane - Bât. Uranus<br />

1, rue Hélène Boucher<br />

78284 Guyancourt Cedex, France<br />

Tel.: +33 130 96 13 00<br />

Fax: +33 130 43 60 85<br />

<strong>Terumo</strong> Deutschland GmbH<br />

Ludwig-Erhard-Strasse 6<br />

65760 Eschborn, Germany<br />

Tel.: +49 6196 80 230<br />

Fax: +49 6196 80 23 200<br />

<strong>Terumo</strong> Deutschland GmbH<br />

Zweigniederlassung Spreitenbach<br />

Bodenäckerstrasse 3<br />

8957 Spreitenbach, Switzerland<br />

Tel.: +41 56 419 10 10<br />

Fax: +41 56 419 10 11<br />

<strong>Terumo</strong> <strong>Europe</strong> España SL<br />

Avda. Juan Carlos I, Nº 13 - 7ª Planta<br />

Edificio Torre La Garena<br />

28806 Alcalá de Henares (Madrid),<br />

Spa<strong>in</strong><br />

Tel.: +34 9021 01 298<br />

Fax: +34 9021 01 358<br />

Holders for CAPIOX ® FX Oxygenators<br />

Holder for FX05 <strong>oxygenator</strong> .............................................................XX*CXH05..................... 1<br />

Holder for FX05 <strong>oxygenator</strong> with hardshell reservoir .....................XX*CXH05R..................... 1<br />

Adapter for SX holder for FX05 ................................................... XX*CXH05AD..................... 1<br />

Holder for FX15/25 <strong>oxygenator</strong> with<br />

hardshell reservoir (short arm) ............................................................801139..................... 1<br />

Holder for FX15/25 <strong>oxygenator</strong> with<br />

hardshell reservoir (long arm) .............................................................801804..................... 1<br />

Holder for FX25 <strong>oxygenator</strong> (US only) ..................................................812613..................... 1<br />

Holder for FX15 <strong>oxygenator</strong> (US only) ..................................................812614..................... 1<br />

Holder for FX15/25 <strong>oxygenator</strong> .......................................................XX*CXH15..................... 1<br />

Holder for FX15/25 <strong>oxygenator</strong> when<br />

seperated from reservoir...............................................................XX*CXH25F..................... 1<br />

Holder for FX15/25 <strong>oxygenator</strong> with<br />

hardshell reservoir (<strong>Europe</strong> only) ...................................................XX*CXH18R..................... 1<br />

Holder for FX15/25 <strong>oxygenator</strong> with<br />

hardshell reservoir, short arm (<strong>Europe</strong> only) ....................................XX*XH032..................... 1<br />

1 Conta<strong>in</strong>s 2 adapters 3/16“ - 1/4“ and a recirculation l<strong>in</strong>e<br />

2 Conta<strong>in</strong>s 4 adapters 3/16“ - 1/4“, 1 adapter 1/4“ - 3/8“ and<br />

a recirculation l<strong>in</strong>e<br />

3 Conta<strong>in</strong>s 2 adapters 1/4“ - 3/8“<br />

4 Conta<strong>in</strong>s 4 adapters 1/4“ - 3/8“<br />

<strong>Terumo</strong> Italia S.r.l.<br />

Via Simone Mart<strong>in</strong>i, 143 / 145<br />

00142 Roma RM,<br />

Italy<br />

Tel.: +39 0651 96 14 20<br />

Fax: +39 0650 30 407<br />

<strong>Terumo</strong> Sweden AB<br />

Nya Varvet, Byggnad 90<br />

Sven Källfelts Gata 18<br />

426 71 Västra Frölunda,<br />

Sweden<br />

Tel.: +46 3174 85 880<br />

Fax: +46 3174 85 890<br />

<strong>Terumo</strong> Denmark<br />

Filial of <strong>Terumo</strong> Sweden AB<br />

Tel.: +45 7020 93 80<br />

Fax: +45 7020 94 80<br />

<strong>Terumo</strong> UK Ltd<br />

Tamesis<br />

The Causeway<br />

Egham, Surrey<br />

TW20 9AW, United K<strong>in</strong>gdom<br />

Tel.: +44 1784 476 200<br />

Fax: +44 1784 476 201<br />

<strong>Terumo</strong> <strong>Europe</strong> n.v.<br />

Moscow Representative Office<br />

BC Northern Tower<br />

13Fr., 10 Testovskaya Street<br />

Moscow 123317, Russia<br />

Tel.: + 7 495 988 4740<br />

Fax: + 7 495 988 4739<br />

Addresses subject to change,<br />

please consult our Website.<br />

® Registered Trademark<br />

Published by <strong>Terumo</strong> <strong>Europe</strong> N.V.<br />

CV134 GB-1011FK-II 0.5 (10.11)E

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!