^?TIAT Qfi- V d.Ui'pftvVCA<br />
3. The inspection of <strong>the</strong> ground should normally include<br />
inspection of <strong>the</strong> following items:-<br />
(a) any part of <strong>the</strong> ground where an accident or incident<br />
resulting in serious injury to spectators has occurred since <strong>the</strong><br />
last inspection;<br />
(b) any recorded defect or deficiency which has arisen since <strong>the</strong><br />
last inspection and which, in <strong>the</strong> opinion of <strong>the</strong> inspecting<br />
officer would be likely to lead to an accident which could result<br />
in serious injury to spectators;<br />
(c) major remedial work carried out since <strong>the</strong> date of <strong>the</strong> last<br />
inspection to ascertain that it has been satisfactorily carried<br />
out;<br />
(d) all public stairways for <strong>the</strong>ir general condition, slip<br />
resistance, condition of hand-rails (see also (D) below), trip<br />
hazards especially at <strong>the</strong> head of stairways, adequacy of lighting<br />
and structural fire separation; — ■<br />
(e) all egress routes used by <strong>the</strong> public, including emergency<br />
exit r uutes, for obstructions, operation of exit gates, adequacy<br />
of sigi-posting and lighting, presence of any uncleared litter;<br />
(^f) fire fighting equipment and fire warning system (if<br />
installed);<br />
(■f-tfl ^ ^ Vfty /Vv> / ^ectator Accommodation <strong>the</strong>rein shall be maintained free from<br />
obstruction and with non-slip and even surfaces and in particular<br />
stair coverings shall be secured and maintained so that <strong>the</strong>y do not<br />
constitute a source of danger.<br />
10. The Holder shall ensure that, except where o<strong>the</strong>rwise marked on <strong>the</strong> Plans,<br />
all doors and gates which form an egress route between any spectator - •<br />
accommodation and <strong>the</strong> public highway, or o<strong>the</strong>r open space outside <strong>the</strong> •<br />
stadium, shall be so secured as to open immediately and easily from <strong>the</strong> inside<br />
and shall be manned at all times by at least <strong>the</strong> number of stewards required<br />
by Part 2 of Schedule 3. All such doors or gates shall be opened by <strong>the</strong><br />
stewards responsible and secured in <strong>the</strong> fully open position at a time before<br />
<strong>the</strong> end of a Specified Activity agreed between <strong>the</strong> Holder and <strong>the</strong> Chief<br />
Constable and at any o<strong>the</strong>r time on evacuation of <strong>the</strong> Stadium or a part<br />
<strong>the</strong>reof on being ordered so to do by a police officer in uniform or by <strong>the</strong><br />
sounding of <strong>the</strong> alarm.<br />
i'g) for <strong>the</strong> presence of any accumulation of litter, 22. No accumulation of flammable rubbish, dirt, surplus material or goods shall<br />
be permitted to remain in any part of <strong>the</strong> Stadium except in a place and quantity<br />
“ approved in writing by <strong>the</strong> Chief Fire Officer. ----- -<br />
(h) <strong>the</strong> emergency lighting system including any generator or<br />
batteries --- — ■<br />
(i) first-aid facilities and equipment;<br />
(2.(1) Subject to such interim arrangements as may be agreed by <strong>the</strong> Chief Fire Officer,<br />
<strong>the</strong> Holder shall provide and maintain to <strong>the</strong> satisfaction of <strong>the</strong> Chief<br />
Fire Officer a separate emergency power supply for providing<br />
electricity sufficient to light all emergency lighting throughout <strong>the</strong><br />
Stadium, all exit signs and powering all <strong>the</strong> communication systems ”<br />
within <strong>the</strong> Stadium, such emergency power supply to be operable<br />
independently of <strong>the</strong> main power supply and to come into automatic<br />
operation within ten seconds of <strong>the</strong> failure of <strong>the</strong> latter and to be<br />
^capable of maintaining <strong>the</strong> necessary power output for a minimum of<br />
three hours from <strong>the</strong> failure of <strong>the</strong> main power supplj7.<br />
8 (1) Subject to such Interim arrangements as may be agreed by <strong>the</strong> County Council<br />
<strong>the</strong> Holder shall provide and maintain at ths Stadium to <strong>the</strong> satisfaction<br />
of <strong>the</strong> County Council a suitably equipped First Aid Room. The first<br />
aid room shall be adequately signed and shall be capable of being lit<br />
by <strong>the</strong> emergency power supply referred to in paragraph 12 of this<br />
Schedule.