Underground Petroleum Storage Tanks and Related Wastes - Code ...
Underground Petroleum Storage Tanks and Related Wastes - Code ...
Underground Petroleum Storage Tanks and Related Wastes - Code ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
- Current Dangerous Goods Licence covering storage <strong>and</strong> disposal area;<br />
<strong>and</strong><br />
- Approval from Local Authorities for disposal of hazardous wastes at<br />
l<strong>and</strong>fills <strong>and</strong>/or other approved methods.<br />
• Insurance appropriate to the contractor’s activities covering:<br />
- Public liability property damage, including pollution cover;<br />
- Public liability personal injury; <strong>and</strong><br />
- Vehicle fleet insurance for l<strong>and</strong> transportation of hazardous substances.<br />
• Transport certification for compliance of vehicle <strong>and</strong> driver.<br />
• Vapour tester of a type <strong>and</strong> model approved by the Chief Inspector of<br />
Dangerous Goods for use with petroleum vapours, including those from<br />
leaded gasoline. It shall be capable of:<br />
- Detecting the presence <strong>and</strong> concentration of petroleum vapours;<br />
- Detecting petroleum vapours from leaded gasolines without the<br />
explosimeter element being damaged or the calibration of the instrument<br />
upset;<br />
- Showing the lower concentrations in their relationship to the lower<br />
explosive limit (0 to 100%); <strong>and</strong><br />
- Indicating higher vapour concentrations.<br />
The explosimeter must be accompanied by a calibration test register giving<br />
calibration procedure <strong>and</strong> settings, signed by a competent person.<br />
• Oxygen meter (if applicable) capable of measuring the oxygen content of the<br />
atmosphere to + 0.3% from 0 to 25% <strong>and</strong> having current calibration<br />
certificates issued by a recognised servicing organisation <strong>and</strong> a calibration<br />
test register signed by a competent person.<br />
• Medical programmes in terms of section 8.5.<br />
• Safety programme, <strong>and</strong> record of any accidents or incidents over previous<br />
three years.<br />
• Site, plant <strong>and</strong> equipment suitable <strong>and</strong> adequate for the work undertaken.<br />
See checklist contained in section 15 of this code.<br />
• Operators competent in the use of test equipment.<br />
• Emergency response plan.<br />
Should a contractor fail to maintain his/her procedures <strong>and</strong> practices, records <strong>and</strong><br />
equipment to an acceptable st<strong>and</strong>ard, any existing approved certification may be<br />
withdrawn.<br />
8.2 Work Authorisation<br />
Only contractors accredited by an Inspector of Dangerous Goods <strong>and</strong> the principal<br />
will be permitted to carry out the work of transportation, storage of tanks, dismantling<br />
operations, collecting <strong>and</strong> storage of wastes <strong>and</strong> storage of steel awaiting<br />
disposal for underground petroleum storage tanks or other tanks that have<br />
contained flammable <strong>and</strong>/or toxic substances.<br />
Transport <strong>and</strong> Disposal of <strong>Petroleum</strong> <strong>Storage</strong> <strong>Tanks</strong> 11