- Current Dangerous Goods Licence covering storage <strong>and</strong> disposal area;<br />

<strong>and</strong><br />

- Approval from Local Authorities for disposal of hazardous wastes at<br />

l<strong>and</strong>fills <strong>and</strong>/or other approved methods.<br />

• Insurance appropriate to the contractor’s activities covering:<br />

- Public liability property damage, including pollution cover;<br />

- Public liability personal injury; <strong>and</strong><br />

- Vehicle fleet insurance for l<strong>and</strong> transportation of hazardous substances.<br />

• Transport certification for compliance of vehicle <strong>and</strong> driver.<br />

• Vapour tester of a type <strong>and</strong> model approved by the Chief Inspector of<br />

Dangerous Goods for use with petroleum vapours, including those from<br />

leaded gasoline. It shall be capable of:<br />

- Detecting the presence <strong>and</strong> concentration of petroleum vapours;<br />

- Detecting petroleum vapours from leaded gasolines without the<br />

explosimeter element being damaged or the calibration of the instrument<br />

upset;<br />

- Showing the lower concentrations in their relationship to the lower<br />

explosive limit (0 to 100%); <strong>and</strong><br />

- Indicating higher vapour concentrations.<br />

The explosimeter must be accompanied by a calibration test register giving<br />

calibration procedure <strong>and</strong> settings, signed by a competent person.<br />

• Oxygen meter (if applicable) capable of measuring the oxygen content of the<br />

atmosphere to + 0.3% from 0 to 25% <strong>and</strong> having current calibration<br />

certificates issued by a recognised servicing organisation <strong>and</strong> a calibration<br />

test register signed by a competent person.<br />

• Medical programmes in terms of section 8.5.<br />

• Safety programme, <strong>and</strong> record of any accidents or incidents over previous<br />

three years.<br />

• Site, plant <strong>and</strong> equipment suitable <strong>and</strong> adequate for the work undertaken.<br />

See checklist contained in section 15 of this code.<br />

• Operators competent in the use of test equipment.<br />

• Emergency response plan.<br />

Should a contractor fail to maintain his/her procedures <strong>and</strong> practices, records <strong>and</strong><br />

equipment to an acceptable st<strong>and</strong>ard, any existing approved certification may be<br />

withdrawn.<br />

8.2 Work Authorisation<br />

Only contractors accredited by an Inspector of Dangerous Goods <strong>and</strong> the principal<br />

will be permitted to carry out the work of transportation, storage of tanks, dismantling<br />

operations, collecting <strong>and</strong> storage of wastes <strong>and</strong> storage of steel awaiting<br />

disposal for underground petroleum storage tanks or other tanks that have<br />

contained flammable <strong>and</strong>/or toxic substances.<br />