GE Healthcare<br />

Life Sciences<br />

New <strong>Amersham</strong> TM <strong>ECL</strong> TM <strong>Prime</strong><br />

The latest addition to the <strong>Amersham</strong> <strong>ECL</strong> family, <strong>Amersham</strong> <strong>ECL</strong> <strong>Prime</strong> consolidates and builds on the<br />

benefits of <strong>Amersham</strong> <strong>ECL</strong> Plus and <strong>Amersham</strong> <strong>ECL</strong> Advance to deliver a detection system that is sensitive,<br />

stable, quantitative, and conservative in its consumption of expensive antibody reagents.<br />

Improved sensitivity with <strong>ECL</strong> <strong>Prime</strong><br />

<strong>Amersham</strong> <strong>ECL</strong> <strong>Prime</strong> <strong>Amersham</strong> <strong>ECL</strong> Plus<br />

2.5 ng 2.4 pg 2.5 ng 9.8 pg<br />

Fig 1. Western blotting detection of transferrin in a 2-fold dilution series using <strong>Amersham</strong><br />

<strong>ECL</strong> <strong>Prime</strong> (left) and <strong>Amersham</strong> <strong>ECL</strong> Plus (right). The samples were blotted onto an <strong>Amersham</strong><br />

Hybond-P (PVDF) membrane and imaged using an ImageQuant LAS 4000 mini system.<br />

<strong>Amersham</strong> <strong>ECL</strong> <strong>Prime</strong> features and benefits<br />

Sensitivity and precision Detects both high and low abundant<br />

proteins as well as phosphorylated<br />

proteins<br />

High intensity and<br />

stability<br />

Quantitative detection<br />

of target proteins<br />

Efficient in the use of<br />

precious antibodies<br />

Convenient handling and multiple<br />

exposures of the same blot due to<br />

long lasting signals<br />

Optimal for protein quantitation due<br />

to broad dynamic range<br />

Detects low quantities of proteins<br />

even when highly diluted antibodies<br />

are used<br />

<strong>Amersham</strong> <strong>ECL</strong> <strong>Prime</strong><br />

Horseradish peroxidase<br />

(HRP)-linked secondary<br />

antibody<br />

Primary antibody<br />

Target protein<br />

HRP<br />

Chemiluminescence<br />

Fig 2. The reaction between <strong>Amersham</strong> <strong>ECL</strong> <strong>Prime</strong><br />

reagent and HRP linked to a secondary antibody. HRP<br />

catalyzes the conversion of <strong>Amersham</strong> <strong>ECL</strong> <strong>Prime</strong><br />

reagent to a sensitized molecule, which on further<br />

oxidation produces an excited product that emits light<br />

when it decays.


<strong>Amersham</strong> <strong>ECL</strong> <strong>Prime</strong> <strong>specifications</strong><br />

Detection limit ~ 2 pg<br />

Signal duration Up to 3 h, using constant exposure time<br />

Working solution stability 24 h at room temperature<br />

Stock solution shelf life 12 mo at 4-8°C<br />

Recommended dilution range<br />

for primary antibody<br />

1:1000 -1:50000<br />

Recommended dilution range<br />

for secondary antibody<br />

1:50000 - 1:250000<br />

Examples of application • Detection and quantitation of posttranslational modifications<br />

• Detection of different protein levels as a response to treatment<br />

Ordering information<br />

Product VWR Cat. No.<br />

<strong>Amersham</strong> <strong>ECL</strong> <strong>Prime</strong> Western Blotting Detection 89168-782<br />

Reagents for 1000 cm 2 membrane 1<br />

1 Includes Solution A (luminol solution, 50 ml) and Solution B (peroxide solution, 50 ml),<br />

sufficient for 1000 cm 2 membrane.<br />

Related products 2 VWR Cat. No.<br />

<strong>Amersham</strong> Hybond-P (20 x 20 cm), 10 sheets 95038-368<br />

<strong>ECL</strong> <strong>Prime</strong> Blocking Agent, 20 g 95040-068<br />

<strong>ECL</strong> Human IgG, HRP-Linked Whole Ab 95017-326<br />

(from sheep), 1ml<br />

<strong>ECL</strong> Rabbit 1gG, HRP-Linked Whole Ab 95017-556<br />

(from donkey), 1ml<br />

Full-Range Rainbow Molecular Weight 95040-114<br />

Markers 250 µl<br />

<strong>ECL</strong> DuaVue Western Blotting Markers 95038-574<br />

(25 loadings)<br />

2 For a more comprehensive list of related products, please refer to www.gelifesciences.com/ecl<br />

Please ask your local sales representative about<br />

receiving a sample of <strong>ECL</strong> <strong>Prime</strong> for evaluation<br />

GE, imagination at work, and GE monogram are trademarks of General Electric Company.<br />

<strong>Amersham</strong> and <strong>ECL</strong> are trademarks of GE Healthcare companies.<br />

© 2011 General Electric Company—All rights reserved.<br />

First published November 2009.<br />

0311 Lit. No. POD 07061