10.04.2013 Views

General and Technical Specifications For Construction of Hostels at ...

General and Technical Specifications For Construction of Hostels at ...

General and Technical Specifications For Construction of Hostels at ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>General</strong> <strong>and</strong> <strong>Technical</strong> <strong>Specific<strong>at</strong>ions</strong> <strong>For</strong> <strong>Construction</strong> <strong>of</strong> <strong>Hostels</strong> <strong>at</strong> PDPU Campus,<br />

G<strong>and</strong>hinagar.<br />

Title – M<strong>at</strong>erial <strong>Specific<strong>at</strong>ions</strong> – Civil Works<br />

47A.5 Tolerance <strong>of</strong> length <strong>and</strong> breadth shall be + 1 mm. Tolerance <strong>of</strong> thickness shall be + 5 mm.<br />

HCP Design <strong>and</strong> Project Management Pvt. Ltd. Ahmedabad<br />

Section: D<br />

Sheet 25 OF<br />

44<br />

47A.6 The tiles shall s<strong>at</strong>isfy the test as regards transverse strength, resistance to wear <strong>and</strong> w<strong>at</strong>er absorption as per IS :<br />

1237.<br />

Testing St<strong>and</strong>ards :<br />

A. W<strong>at</strong>er Absorption :<br />

Sampling :<br />

6 tiles out <strong>of</strong> every 3000 tiles are taken for testing.<br />

Results :<br />

Absorption permissible, shall be <strong>at</strong> the most 10%.<br />

B. Transverse strength test :<br />

Sampling :<br />

12 tiles out <strong>of</strong> every 3000 tiles are taken for testing.<br />

Results :<br />

When wet :- 80 Kg/cm 2 .<br />

When dry :- 120 Kg/cm 2 .<br />

C. Abrasion test :<br />

Sampling :<br />

6 tiles out <strong>of</strong> every 3000 tiles are taken for testing.<br />

Results :<br />

Average abrasion shall not be more than 3.5 mm.<br />

M-47B Plain Coloured Tiles :<br />

47B.1 These tiles shall have the same specific<strong>at</strong>ions as plain cement tiles, as in 47A above except th<strong>at</strong> they shall have a<br />

plain wearing surface, wherein pigments are used. They shall conform to IS : 1237.<br />

47B.2 The pigments used for colouring cement shall not exceed 10% by weight <strong>of</strong> cement used in the mix. The pigments,<br />

synthetic or otherwise, used for colouring tiles shall have permanent colour <strong>and</strong> shall not contain m<strong>at</strong>erials<br />

detrimental to concrete.<br />

47B.3 The colour <strong>of</strong> the tiles shall be specified in the item or as directed.<br />

M-47C Marble Mosaic Tiles :<br />

47C.1 These tiles have the same specific<strong>at</strong>ions as plain cement tiles except for the requirements st<strong>at</strong>ed below:<br />

47C.2 The marble mosaic tiles shall conform to IS : 1237. The wearing face <strong>of</strong> the tiles shall be mechanically ground <strong>and</strong><br />

filled. The wearing face <strong>of</strong> tiles shall be free from projections, depressions <strong>and</strong> cracks <strong>and</strong> shall be reasonably parallel<br />

to the backing <strong>of</strong> the tiles. All angles shall be right angles <strong>and</strong> all edges shall be sharp <strong>and</strong> true.<br />

47C.3 Chips used in the tiles shall be <strong>of</strong> the smallest size upto 20 mm. size. The minimum thickness <strong>of</strong> the wearing layer <strong>of</strong><br />

tiles shall be 6 mm. <strong>For</strong> p<strong>at</strong>tern <strong>of</strong> chips required on the wearing face, a few samples with or without their full size<br />

photographs, as directed shall be presented to the Engineer-in-charge <strong>and</strong> Architect, for approval.<br />

47C.4 Any particular sample, if found suitable shall be approved by the Engineer-in-charge <strong>and</strong> Architect, or he may ask for<br />

a few more samples to be presented. The samples shall have to be made by the Contractor till a suitable sample is<br />

finally approved for use in the work. The Contractor shall ensure th<strong>at</strong> the tiles supplied for the work shall be in<br />

conformity with the approved sample only, in terms <strong>of</strong> its dimensions, thickness <strong>of</strong> the backing layer <strong>and</strong> wearing<br />

surface, m<strong>at</strong>erials, ingredients, colour shade, chips distribution, etc. required.<br />

47C.5 The tiles shall be prepared from cement conforming to IS or coloured Portl<strong>and</strong> cement, generally depending upon the<br />

colour <strong>of</strong> tiles to be used or as directed.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!