Features SYNMET / LOG and SYNMET / LOG-D<br />

• Configurable, free of maintenance and modular automatic data<br />

logging and processing system (Automatic Weather Station)<br />

Operating temperature range -30...+70 °C<br />

24 V DC power supply with overvoltage protection<br />

Sturdy and reliable construction consisting of aluminium diecast<br />

housing with EMC cable glands<br />

Easy and professional installation with plug-terminals in spring<br />

contact technology without needing special tools<br />

Maintenable and expandable with exchangeable modules<br />

12 analogue and 5 digital inputs for voltage, current, resistance,<br />

frequency, status and contact<br />

Incorporated sensor excitation and optional barometric pressure<br />

sensor<br />

Optional exchangeable overvoltage protection for all sensor<br />

inputs (ESD-module, discharge and overvoltage)<br />

16 Bit microcontroller, 512 kB Flash-E<strong>PR</strong>OM and 512 kB RAM<br />

Dynamic organized ring memory for mean and extreme values<br />

Serial ports for sensors, PC/Laptop and modems<br />

Firmware support by means of Flash-E<strong>PR</strong>OM-Technology<br />

Remote control via telephone, GSM-Modems and radio link<br />

Built-In-Test-Faciliy (BITE) for sensor and hardware control<br />

Additional performances for SYNMET / LOG-D<br />

Keyboard and LC-Display for easy maintenance<br />

Direct connection for solar panel by Battery-Load-Management<br />

Incorporated uninterruptable power supply with 0.8 Ah Accu<br />

Optional moduls: DAC, Sensor Interface and Serial Interface<br />

SYNMET-Commander<br />

PC-Software for WINDOWS 95/98/NT<br />

Display of parameter values and error status<br />

Configuration of sensor parameters, serial interfaces and alarm<br />

function<br />

Centralized station management and remote control via modem<br />

Applications<br />

Automatic or manned SYNoptical and METeorological<br />

weatherstation (WMO) for:<br />

Agricultural meteorological station<br />

Climatological station<br />

Semi-automatic observer station<br />

Forest wardens<br />

Mobile or transportable station<br />

Industrial surveying station<br />

Renewable energy purposes<br />

Waste surveying station<br />

Indoor climate control<br />

Standards<br />

Construction according to 72/23/EWG and VDE 100<br />

EMC according to EN 50082/81<br />

ESD protection according to IEC 1000-4-5 and MIL STD 3015.7<br />

Report Coding according to WMO No. 306<br />

<strong>PR</strong><strong>ODUCT</strong> <strong>INFORMA</strong><strong>TION</strong> SYNMET / LOG and SYNMET / LOG-D (665)


Product Information<br />

SYNMET / LOG and SYNMET / LOG-D (665)<br />

Microcontroller and Firmware<br />

CMOS 16-Bit microcontroller NEC-V25 with watchdog<br />

and power fail interrupt<br />

512 kB battery-buffered RAM and 512 kB Flash-E<strong>PR</strong>OM<br />

8 kB EE<strong>PR</strong>OM as configuration memory<br />

2 serial UARTs with interrupt logic for transmit and<br />

receive task<br />

- Firmware with meteorological Know How for various<br />

sensor interfacings, data-processes and SYNOPgeneration<br />

- Easy software-update with Flash-E<strong>PR</strong>OM technology in<br />

case of essential performed functions<br />

- Auto-start of the system configuration and survival mode<br />

in case of a malfunction of the system-software and its<br />

watchdog activities<br />

- Remote configuration and maintenance by manufacturer<br />

or service staff<br />

User- and Display-Terminal (Version LOG-D)<br />

20 Characters / 4-Line LC-Display<br />

keyboard with16 alphanumerical control keys<br />

- Simple function check without external computers<br />

- Display of instantaneous values and failure-status<br />

Serial Test- and Configuration-Interface<br />

9 pin D-Sub connector (RS 232)<br />

- On-site data retrieve via Laptop<br />

- Interface for diagnostic and configuration with software<br />

SYNMET-Commander<br />

Optional Barometric Pressure Sensor<br />

Incorporated electronic precision barometric sensor with<br />

analogue output 0...5 VDC<br />

Two measuring ranges available: 600...1060 hPa and<br />

800...1060 hPa; accuracy: 0.5 hPa and 0.3 hPa<br />

- Wide operating range from sea level to 4000 m without<br />

any altitude correction<br />

- Installation set (incorporated) for later upgrade<br />

Version LOG-D<br />

Integrated digital high precision barometer with serial<br />

interface RS 485<br />

- Measuring range 35...1310 hPa (accuracy 0.1 hPa)<br />

Operating Elements and Power Connection<br />

LED-Service-Field for power, accumulator load, correct<br />

battery connection, internal supply-voltages and<br />

sensor-excitation<br />

Operating switches for power, battery-off and battery<br />

load<br />

8 selectable precision shunt-resistors 100 Ohms for<br />

current inputs of 0/4-20 mA<br />

Terminals for DC-Input, solar panel and external battery<br />

Distributor terminals for external wind sensor heatingdevice<br />

Fuses, DC-filter and overvoltage protection for DC-input<br />

- Easy installation and maintenance by means of simple<br />

LED-status field for service staff<br />

- Circuit breaker for the system, including battery<br />

for transportation, storage, installation and maintenance<br />

- Universal and wide range power inputs with intelligent<br />

incorporated electronic control device for batterymanagement<br />

Universal Power Supply Electronic (Version LOG-D)<br />

Temperature controlled battery charge management for<br />

incorporated UPS and external battery up to 40 Ah<br />

Uninterrupted power supply with incorporated accumulator<br />

Electronic device for all power input facilities<br />

- Direct connection of solar panel and battery<br />

- Uninterrupted operation by power failure during several hours<br />

- Housekeeping data available as configurable sensors (battery<br />

voltage, battery current and solar current)<br />

Optional Interchangeable ESD-Module<br />

ESD-/Overvoltage-Module for all analogue and digital sensor<br />

inputs according to human-body-model for direct discharge, air<br />

discharge and peak current<br />

- Netstar concept to internal power lines and surge protection to<br />

protect earth<br />

- Continous acquisition by removing the ESD-module in<br />

maintenance-mode without any change of installation


Housing technology<br />

- Rugged and long life expectance, Aluminium diecast housing<br />

with excellent EMC-Features<br />

- Easy handling due to small dimensions and weight during<br />

transport and installation<br />

- Designed for outdoor installation in extreme climate and environmental<br />

conditions<br />

- Separated compartment for electronic devices and installation<br />

terminals<br />

- Conductive metal cable glands with EMC / EMI-safe shielding<br />

technology<br />

Serial Interfaces<br />

COM1: RS 232 and galvanically isolated RS 422 ports<br />

COM2: RS 232<br />

- Redundant and independent operation for station-PC, central<br />

station, modem, serial sensors, digital Displays and SYNOP-<br />

Terminal<br />

- Polling or active dialling and send-mode by alarm conditions or<br />

time events (SYNOP)<br />

- Data transmission with short distance drivers, telephone-, GSMor<br />

radio-modems<br />

Optional SI-Modul (Version LOG-D)<br />

- RS 422 / RS 485 Interfaces, galvanically isolated<br />

- RS 485-Network consisting of various serial sensors<br />

- RS 485-Network consisting of several SYNMET-stations<br />

Optional Sensor Interface Module (Version LOG-D)<br />

Voltage divider and resistor array for 4 analogue inputs<br />

12 V DC/DC-converter / 10 VA<br />

2 relays with computable contacts<br />

Interface-Converter RS 422/485 for COM2-Port,<br />

galvanically isolated<br />

- Adaption of specific sensors with required impedance<br />

(sensors with generators and voltages 5...30 V)<br />

- Computable power excitation for external devices like<br />

sensors, modems or ventilators with power control<br />

- Programmable Alarm-Output with logical combination<br />

- Connection of serial sensors or additional PCs and<br />

modems for distances up to 1000 m<br />

Options for Piggy Back Slot (Version LOG-D)<br />

DAC-Module<br />

• 8 high precision analogue outputs (12 Bit)<br />

Programmable output in range of 0...20 mA and 0...10 V<br />

Configurable sensor selection and scaling<br />

- Easy adaption on existing analogue devices like<br />

indicators, chart recorders, control units etc.<br />

- High operation reliability by galvanic and optoelectronic<br />

insulation to data acquisition system<br />

RS-Module<br />

Four serial Interfaces RS 232/422/485<br />

Galvanically isolated RS 422/485 line drivers<br />

- Connection of serial Sensors like cloud height, visibility<br />

etc.<br />

- Intelligent configurable Sensor interface (ASCII)<br />

Digital Coummutable Outputs<br />

- 2 open collector outputs for alert purposes and event<br />

control<br />

Version LOG-D: 2 optional relay outputs<br />

12 Analogue and 5 Digital Universal and Configurable<br />

Sensor Inputs<br />

Differential inputs with a programmable gain of 1...100<br />

and integrated low-pass filter<br />

Sensor excitation 12 / 24 V DC, short circuit protected and<br />

galvanically isolated<br />

Four-Wire-Circuit and constant current source 1 / 10 mA<br />

for resistance measurement<br />

8 precision shunt resistors for current measurement<br />

Intergrated characteristic compensation of Pt 100 with<br />

accuracy 0.1 degrees<br />

12 Bit sampling ADC for bipolar and unipolar<br />

measurements with type 12 ms converting time<br />

16 Bit Counter for frequencies, events and binary status<br />

- Connection of various sensors for meteorological and<br />

industrial applications<br />

- Remote control and configuration of sensors and system<br />

parameters via serial link<br />

- Easy and safe installation and monitoring of the system<br />

by operating staff<br />

- Highly sophisticated and precise data acquisition<br />

- Capacity of up to 40 physical and calculated sensorslike<br />

dew point, temperature, QNH, QFE etc.<br />

- Automatic and periodic reference measurements for the<br />

compensation of offset, gain and temperature drift<br />

- Digital software filter for peak-detect and qualitymonitoring<br />

of sensor signal<br />

- Detailed error identification like over-range, bad-signal,<br />

open channel and short circuit<br />

- Selectable input channels for solar-I and battery-I/U


Product Information<br />

SYNMET / LOG and SYNMET / LOG-D (665)<br />

General Environmental Conditions<br />

Operating temperature range: -30...+70° C<br />

Humidity: 0...100% (not condensing)<br />

System components<br />

Housing and Power Supply<br />

Diecast aluminium housing with 20 EMC/EMI cable glands,<br />

Dimensions: 306x241x136 mm (WxHxD), weight: 8 kg<br />

Mother board with 6 sixfold EMC-multi-layers<br />

Plug-Terminals for 12 analogue and 5 digital sensors<br />

Plug-Terminals for 2 RS 232-COM-ports and RS 422,<br />

galvanically isolated<br />

Power Supply-Terminals with fuses, switches and overvoltage<br />

protection<br />

Power supply: 18...32 V DC<br />

Power consumption approximately 1.5 VA<br />

12/24 V DC sensor excitation 3 VA, jumper selectable<br />

Version LOG-D<br />

Extention-Terminals for DAC-, RS- and SI-modules<br />

Maximum power consumption 30 VA (UPS, DAC-module,<br />

external battery load, 10 VA-module)<br />

Solar panel capacity 20...50 W, 17...25 V DC<br />

Integrated charger for internal and external battery<br />

(12 VDC / 0.8...40 Ah)<br />

Internal UPS battery (12 V DC / 0.8 Ah)<br />

CPU-board for universal sensor inputs with programmable<br />

gain and software filter for 12 analogue and 5 digital inputs<br />

Accuracy: 12 Bit sampling ADC / 8 µs converting time<br />

Resolution: 14 Bit ADC with 32...64 oversampling<br />

(0.5 ms converting time)<br />

Accuracy: ±0.02%, ±0.1% with internal shunt resistor<br />

Input resistance range: Pt100, 125, 250, 500, 1250,<br />

2500, 5000 Ohm<br />

Input voltage: 0.05 / 1.25 / 2.5 / 5.0 / ±0.025 / ±2.5 V DC<br />

3 Digital inputs: H/L-Level 0.5...50V DC<br />

Frequency: 10 kHz<br />

Proximity switch according to NAMUR: 1/10 kOhm<br />

2 Digital status inputs (0.5...50 V DC)<br />

Controller: 16 Bit NEC V25<br />

Clock frequency: 8 MHz<br />

Data memory: battery buffered RAM 512 kB<br />

Configuration memory: 8 kB EE<strong>PR</strong>OM<br />

Program memory: 512 kB Flash E<strong>PR</strong>OM<br />

Y2K compliant real time clock (accuracy ±30 sec/month)<br />

Multitasking acquisition: 1...60 sec<br />

Mean intervals: 1...60 min<br />

Multitasking communication: Baud rates 300...38400<br />

2 Interfaces RS 232 with hardware handshake RTS/CTS<br />

1 Interface RS 422, galvanically isolated<br />

Version LOG-D<br />

4 lines (20 characters each) LC-Display<br />

16 keypads for alphanumeric and control inputs<br />

Quality System certified by DQS according to<br />

DIN EN ISO 9001 Reg. No. 3748<br />

Wilh. Lambrecht GmbH<br />

Friedländer Weg 65-67<br />

37085 Göttingen<br />

Germany<br />

Tel +49-(0)551-4958-0<br />

Fax +49-(0)551-4958-312<br />

E-Mail info@lambrecht.net<br />

Internet http://www.lambrecht.net<br />

Datalogger<br />

SYNMET / LOG Ord.No.: 00.95665.000 000<br />

consisting of aluminium housing, mainboard and CPU<br />

SYNMET / LOG-D Ord.No.: 00.95665.100 000<br />

consisting of aluminium housing, mainboard and CPU, UPSbattery,<br />

solar/battery-load-management, keyboard + LC-Display<br />

Options for SYNMET / LOG and SYNMET / LOG-D<br />

ESD-Module Ord.No.: 32.95661.009 000<br />

for all analogue and digital sensor inputs<br />

Direct discharge: 8 kV<br />

Air discharge: 15 kV<br />

Peak current: ±3A / 20 µs; ±2A / 100 µs; ±5A / 4 µs<br />

Barometric pressure sensor including assembling kit<br />

Meas. range: 800...1060 hPa Ord.No.: 32.95665.020 010<br />

Accuracy: 0.3 hPa<br />

Meas. range: 600...1060 hPa Ord.No.: 32.95665.020 020<br />

Accuracy: 0.5 hPa<br />

Options for SYNMET / LOG-D only<br />

Barometric pressure sensor including assembling kit<br />

Meas. range: 35...1310 hPa Ord.No.: 32.95665.020 000<br />

Accuracy: 0.1 hPa<br />

(RS 485: SI- or RS-module required)<br />

Sensor Interface Module Ord.No.: 32.95665.008 030<br />

4 Voltage dividers as sensor specific adjustment modules<br />

1 DC/DC Converter 12 V DC / 10 VA power excitation<br />

2 Relais 230 V / 2 A<br />

COM2 as RS 422 / RS 485 as PC- or Sensor-Interface<br />

DAC-Module Ord.No.: 32.95660.004 000<br />

8 Analogue output channels, galvanically isolated and short<br />

circuit protected<br />

Accuracy: ±0.05%<br />

Resolution: ±0.025%<br />

Programmable output current : 0/4...20 mA,<br />

shunt max. 600 Ohm<br />

Output voltage: 0...10 V DC / 3 x 50 mA, 5 x 10 mA<br />

RS-Module Ord.No.: 32.95660.011 000<br />

Interface module for 4 serial sensors<br />

COM3... COM5: RS 232 / RS 422 (galvanically isolated)<br />

COM6: RS 232 / RS 485 (galvanically isolated)<br />

Accessories<br />

SYNMET-Commander and PC cable set<br />

Available System Components<br />

Power supply (pluggable or mast mounting version)<br />

Various sensors, including connection cables<br />

Solar panel, rechargeable battery and installation accessories<br />

10m-Mast as well as portable masts<br />

Interface converters and modems<br />

PC-Software for DOS, WINDOWS 95/98/NT<br />

Specifications subject to change without notice<br />

In more than 100 countries 95665_p-e.p65 21.01