16.04.2013 Views

CONFRONTO CON IL FILTRO H-ALFA BAADER - Skypoint Srl

CONFRONTO CON IL FILTRO H-ALFA BAADER - Skypoint Srl

CONFRONTO CON IL FILTRO H-ALFA BAADER - Skypoint Srl

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SKYPOINT s.r.l.<br />

VIA ZORUTTI (S.S.13) 145/11 CAMPOFORMIDO – UDINE –<br />

TEL 0432 652609 FAX 0432 663473 www.skypoint.it e-mail: info@skypoint.it<br />

<strong><strong>CON</strong>FRONTO</strong> <strong>CON</strong> <strong>IL</strong> F<strong>IL</strong>TRO H-<strong>ALFA</strong> <strong>BAADER</strong><br />

Recently, Baader Planetarium, a manufacturer and distributor of astronomical equipment in Mammendorf,<br />

Germany, introduced a Hydrogen-alpha, or H-a, 656 nm filter specifically designed for astrophotography<br />

using CCD cameras. The filter is stated to have a FWHM (full-width at half-maximum intensity) of 7 nm and<br />

a transmission of 90% and is made with scratch-resistant coating technology. The interesting aspect of this<br />

introduction is the list price of $335 for a 50.8 mm diameter filter. This price includes several markups for the<br />

primary and secondary U.S. distributors. This is considerably less than list price of the 4.5 nm Custom<br />

Scientific H-a filter at $595 or 6 nm Astrodon at $695. The purpose of this study is to compare the Baader<br />

filter with the Astrodon 6 nm H-a filter.<br />

Spectral curves were obtained using Varian Cary 500 high resolution spectrophotometer.<br />

The Astrodon 6 nm filter reaches its maximum throughput of 92.3 %T at the H-a emission wavelength of<br />

656.3 nm. The Baader 7 nm filter reaches its maximum throughput of 89.1%T at 657.5 nm. However, it only<br />

reaches 85.8 %T at the H-a emission wavelength.<br />

Some manufacturers design their peak transmissions on the high side of the emission wavelength, since the<br />

passband shifts toward shorter wavelengths with faster optics. Studies underway show that the Astrodon<br />

filter will maintain its >88%T specification with systems slower than about f/4.5. An angular study has not<br />

been performed on the Baader filter. However, if this spectrum is representative, its use with f/7-10 systems<br />

will be degraded due to its 85%T relative to 92%T of the Astrodon. This goes to the Signal (S) part of the<br />

equation to determine the signal-to-noise, S/N, of the filter.<br />

Narrower filters are nearly always preferred. The problem with narrower filters is manufacturing<br />

reproducibility. For example, Custom Scientific 4.5 nm FWHM filter are specified to have maximum %T<br />

(throughput) >70%. Some filters have 90% and others near 70%. This does not reflect negatively on the<br />

quality of these filters. It is just a recognition of the fact that narrow filter are more difficult to make<br />

<strong>CON</strong>SISTENTLY. We do not have access to different lots of Baader H-a filters, but we can present such<br />

lot-to-lot data for recent Astrodon 6 nm H-a filters, as shown below:


SKYPOINT s.r.l.<br />

VIA ZORUTTI (S.S.13) 145/11 CAMPOFORMIDO – UDINE –<br />

TEL 0432 652609 FAX 0432 663473 www.skypoint.it e-mail: info@skypoint.it<br />

Three of the most important parameters in narrowband filters are the FWHM, the maximum %T and the out-of-band<br />

blocking. We have discussed the first two, and most people are somewhat familiar with what they mean. The out-ofband<br />

blocking is very important. It refers to the degree to which light is rejected OUTSIDE of the passband. Poorer outof-band<br />

blocking will let more light come through your filter, degrading its contrast.<br />

Realize that these H-a filtes let light pass in about a 10-12 nm region, whereas the silicon-based CCD detectors used in<br />

amatuer cameras are sensitive to light from the ultra-violet (UV) to the near-infrared (NIR) up to about 1100 nm. Thus,<br />

more and more coating layers are needed to eliminate the potential light leakage of the filter outside its passband. If you<br />

integrate the area under the curve from 300 to 1100 nm compared to just the area under the curve of the narrow<br />

passband, a small amount of out-of-band leakage adds up quickly. This, in fact, is how you characterize the <strong>CON</strong>TRAST<br />

of a filter relative to a chosen detector and light source.<br />

You cannot see how much light is leaking through the filter outside the passband in %T plots, as shown above. The<br />

signal would be


SKYPOINT s.r.l.<br />

VIA ZORUTTI (S.S.13) 145/11 CAMPOFORMIDO – UDINE –<br />

TEL 0432 652609 FAX 0432 663473 www.skypoint.it e-mail: info@skypoint.it<br />

The comparion of out-of-band blocking between the Astrodon 6 nm and Baader 7 nm H-a filters is show<br />

below:<br />

The NIR (>700 nm) difference is large. Both filters have excellent out-of-band blocking at shorter<br />

wavelengths of OD 6. However, the Baader filter has significantly poorer out-of-band blocking at NIR<br />

wavelengths where many CCD detectors still have considerable sensitivity, such as the KAF3200ME,<br />

KAF6303, back-thinned detectors and the new large KAF16803 andKAF09000. This difference is nearly 3<br />

orders of magnitude and certainly explains part of the cost difference.<br />

This would not be acceptable for professional filters, and Astrodon (and Custom Scientific) filters are made to<br />

professional standards. How does this affect the type of astrophotography mostly done by amatuer<br />

imagers? It will likely not make much of a difference for bright objects, such as M16, M20, the Veil<br />

Supernova remnant, etc. As with narrower filters, it will manifest itself in the fainter areas and fine detail, e.g.<br />

contrast.<br />

To test NIR leakage, I used an Apogee Alta U16M CCD with a Kodak KAF16803 large format CCD<br />

operated at -20C in my dimly lit office with a standard flashlight directed at the ceiling. A flashlight was used<br />

over just a few minutes of time, so changes in lamp intensity should not be a factor. Further, the overhead<br />

room lights are the coiled fluorescent bulbs, and a continuum from an incandescent bulb with NIR intensity<br />

was most appropriate. A calibrated light source is unnecessary to demonstrate the difference in S/N and light<br />

leakage in these tests. The camera was pointed up. A 2" nose piece was secured into the camera holding<br />

a standard 48 mm Astrodon Schuler photometric (Bessell, Johnson-Cousins) IR filter made with 3 mm thick<br />

piece of Schott RG9 glass and 1 mm of KG4 glass. This filter is used to compare the IR leakage of the two<br />

H-a filters, because it blocks the filter's bandpass and all shorter wavelengths. It's scan (Is) is shown below:


SKYPOINT s.r.l.<br />

VIA ZORUTTI (S.S.13) 145/11 CAMPOFORMIDO – UDINE –<br />

TEL 0432 652609 FAX 0432 663473 www.skypoint.it e-mail: info@skypoint.it<br />

MaxImDL was used to collect the 4s scans and CCDStack was used to define identical regions on all scans<br />

and compute the image statistics.<br />

LEFT: Apogee U16M with Bessell IR filter in 2" nose piece<br />

CENTER: H-a filter placed over opening above IR filter<br />

RIGHT: Stack of AP tubes pointed at dimly lit ceiling


SKYPOINT s.r.l.<br />

VIA ZORUTTI (S.S.13) 145/11 CAMPOFORMIDO – UDINE –<br />

TEL 0432 652609 FAX 0432 663473 www.skypoint.it e-mail: info@skypoint.it<br />

LEFT: Photometric IR filter only MEAN ADU 64,074 (saturated) RIGHT: Astrodon 6 nm H-a with ~6 OD Blocking MEAN ADU 332


SKYPOINT s.r.l.<br />

VIA ZORUTTI (S.S.13) 145/11 CAMPOFORMIDO – UDINE –<br />

TEL 0432 652609 FAX 0432 663473 www.skypoint.it e-mail: info@skypoint.it<br />

Baader 7 nm H-a with ~ 2.5 OD Blocking Mean ADU 10,022<br />

Thus, even blocking nearly all UV and VISIBLE light with the IR filter, the KAF16803 detector in the CCD<br />

was saturated with only a flashlight pointed to the ceiling in these tests. The Astrodon 6 nm FWHM H-a filter<br />

rejected all but 332 ADU, whereas the Baader 7 nm filter allowed 10,022 ADU. Thus, the Baader allows a<br />

factor of 10022/332 = 30.2 times the amout of NIR light through that the Astrodon filter rejects with this<br />

camera and broadband incandescent light source. This, of course, is expected from the spectral scans that<br />

show considerably more NIR light leakage from the Baader filter. [Note - there was a dark horizontal band in<br />

the Astrodon image above in the original posting. One of the three frams showed this for unknown reasons.<br />

The above represents a second FITs file take at the same time. The earlier results showed 365 mean ADU<br />

and this showed 332 mean ADU. Thus, this small change is likely within experimental error and does not<br />

change any conclusion].<br />

So, what does all this mean for imaging? As most of you know or suspect, attractive H-a images can be<br />

taken with a variety filtes from the wide 13 nm Astronomik, the 9 nm Astrodon-Schuler, the 7 nm Baader, the<br />

6 nm Astrodon, the 4.5 nm SBIG/Custom Scientific and the special order Custom Scientific 3 nm. There is<br />

no right answer because it depends upon your budget and your objectives for H-a imaging. Greater<br />

transmission with the same FWHM increases S/N. Narrower filters with the same transmission increase<br />

S/N. Thus, with the above optical performance, you will more likely be looking at subtle differences in<br />

contrast with lower level, or background features. With this in mind, we will determine the S/N of several<br />

areas of the Eagle Nebula, M16 taken on the same night under idential condtions with the U16M on an<br />

RCOS 12.5" RC reflector with the Baader 7 nm and Astrodon 6 nm H-a filters. The S/N was determined in<br />

MaxIm, using the following formula (ADU was multipled by the camera gain of 1.2 to convert to e-):<br />

S/N = [(signal - background) ] / sqrt [ Signal + background standard deviation^2 ]


SKYPOINT s.r.l.<br />

VIA ZORUTTI (S.S.13) 145/11 CAMPOFORMIDO – UDINE –<br />

TEL 0432 652609 FAX 0432 663473 www.skypoint.it e-mail: info@skypoint.it<br />

The regions shown were taken in areas without stars. The same dark background region was used (not<br />

shown). The Baader 7nm H-a filter is on the left and the 6 nm Astrodon H-a filter is on the right. A brighter<br />

region next to the Eagle Nebula is analyzed first.<br />

Baader S/N = 3.69; Astrodon S/N = 4.10 11% improvement with Astrodon<br />

A darker region further away is analyzed next:<br />

Baader S/N = 0.92; Astrodon S/N = 1.11 21% improvement with Astrodon.<br />

A brighter region with ridge structure inside the nebula resulted in an improvement in S/N with the Astrodon filter of only<br />

4%. This is consistent with the expectations described above. Both filters produce a pleasing image of the Eagle<br />

Nebula. The advantages of the narrower filter with slightly higher transmission and much better out-of-band blocking<br />

show up in fainter areas and are thus more subtle. Again it really depends upon your goals in astrophotography.<br />

Astrodon will continue to make the best off-the-shelf narrowband filters possible for astrophotography, even if they are<br />

more expensive. We will not sacrifice blocking, transmission, prevention of halos, or manufacturing consistency for a<br />

lower narowband price. For some of you, this is overkill. For others who have spent thousands or even tens of thousands<br />

of dollars or Euros on scopes, mounts and cameras, we offer you filters wihtout compromise.<br />

In short, as in any other aspect of life, there is "no free lunch".

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!