25.04.2013 Views

KV Small-type Distribution Boards up to 63 A - Hensel

KV Small-type Distribution Boards up to 63 A - Hensel

KV Small-type Distribution Boards up to 63 A - Hensel

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>KV</strong> <strong>Small</strong>-<strong>type</strong> <strong>Distribution</strong> <strong>Boards</strong><br />

Circuit Breaker Boxes<br />

Cable Entry via Integrated Elastic Membranes<br />

<strong>KV</strong> 9103<br />

3 modules: 1 x 3 x 18 mm<br />

1-row<br />

per<br />

PE/N number x cross section 1 x 25 mm², 4 x 4 mm² Cu,<br />

FIXCONNECT ® terminal technology,<br />

for terminal technology refer <strong>to</strong> technical data<br />

for<br />

the installation of DIN rail equipment, <strong>to</strong>p hat profile 35 mm<br />

with<br />

transparent lid, sealable<br />

locking<br />

device for hinged lid and sealing facility see accessories<br />

with<br />

cable entry cover<br />

protective<br />

cover can be cut out<br />

cable<br />

entry via integrated elastic membranes<br />

rated insulation voltage AC 400 V<br />

<strong>KV</strong> 8103<br />

3 modules: 1 x 3 x 18 mm<br />

without PE and N terminal<br />

1-row<br />

order<br />

PE/N terminals separately<br />

for<br />

the installation of DIN rail equipment, <strong>to</strong>p hat profile 35 mm<br />

with<br />

transparent lid, sealable<br />

locking<br />

device for hinged lid and sealing facility see accessories<br />

with<br />

cable entry cover<br />

protective<br />

cover can be cut out<br />

cable<br />

entry via integrated elastic membranes<br />

rated insulation voltage AC 400 V<br />

<strong>KV</strong> 1503<br />

3 modules: 1 x 3 x 18 mm<br />

1-row<br />

per<br />

PE/N number x cross section 1 x 25 mm², 4 x 4 mm² Cu,<br />

FIXCONNECT ® terminal technology,<br />

for terminal technology refer <strong>to</strong> technical data<br />

for<br />

the installation of DIN rail equipment, <strong>to</strong>p hat profile 35 mm<br />

with<br />

transparent lid, sealable<br />

locking<br />

device for hinged lid and sealing facility see accessories<br />

with<br />

cable entry cover<br />

protective<br />

cover can be cut out<br />

cable<br />

entry via integrated elastic membranes<br />

rated insulation voltage AC 400 V<br />

<strong>KV</strong> 1603<br />

3 modules: 1 x 3 x 18 mm<br />

without PE and N terminal<br />

1-row<br />

order<br />

PE/N terminals separately<br />

for<br />

the installation of DIN rail equipment, <strong>to</strong>p hat profile 35 mm<br />

with<br />

transparent lid, sealable<br />

locking<br />

device for hinged lid and sealing facility see accessories<br />

with<br />

cable entry cover<br />

protective<br />

cover can be cut out<br />

cable<br />

entry via integrated elastic membranes<br />

rated insulation voltage AC 400 V<br />

IP<br />

65<br />

IP<br />

65<br />

IP<br />

54<br />

IP<br />

54<br />

PS<br />

PS<br />

PS<br />

PS<br />

197<br />

RAL<br />

7035<br />

102<br />

1<br />

Wall<br />

1<br />

PE N 72<br />

54<br />

197<br />

197<br />

46<br />

RAL<br />

7035<br />

46<br />

102<br />

54<br />

RAL<br />

7035<br />

102<br />

92<br />

50<br />

1<br />

Wall<br />

1<br />

92<br />

50<br />

72<br />

1<br />

Wall<br />

1<br />

PE N 72<br />

54<br />

197<br />

46<br />

RAL<br />

7035<br />

46<br />

102<br />

54<br />

92<br />

50<br />

1<br />

Wall<br />

1<br />

92<br />

72<br />

50<br />

137