KV Small-type Distribution Boards up to 63 A - Hensel
KV Small-type Distribution Boards up to 63 A - Hensel
KV Small-type Distribution Boards up to 63 A - Hensel
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
202<br />
<strong>KV</strong> <strong>Small</strong>-<strong>type</strong> <strong>Distribution</strong> <strong>Boards</strong><br />
Technical Details<br />
Operating and Ambient Conditions<br />
<strong>KV</strong> <strong>Small</strong>-<strong>type</strong><br />
distribution<br />
boards and<br />
KWH Meter<br />
boxes<br />
<strong>KV</strong> <strong>Small</strong><strong>type</strong> distribution boards<br />
PS polystyrene<br />
Empty boxes Cable entry<br />
ESM ...,<br />
EVS 16<br />
Application area Ausführung IP 54/65:<br />
Geeignet für Innenräume und die geschützte Installation im<br />
Freien nach DIN VDE 0100 Teil 737<br />
Ambient temperature<br />
- Average value over 24 hours<br />
- Maximum value<br />
- Minimum value<br />
Relative humidity<br />
- short-time<br />
Fire protection<br />
in the case of internal faults<br />
Burning behaviour<br />
- Glow wire test<br />
IEC 60 695-2-11<br />
- UL Subject 94<br />
Degree of protection<br />
against mechanical load<br />
+ 35° C<br />
+ 40° C<br />
− 5° C<br />
50% at 40° C<br />
100% at 25° C<br />
−<br />
+ 60° C<br />
− 25° C<br />
−<br />
−<br />
+ 35° C<br />
+ 40° C<br />
− 25° C<br />
Demands<br />
placed on electrical devices from standards and laws<br />
Minimum requirements<br />
- Glow wire test in accordance with IEC 60 695-2-11:<br />
- 650° C for boxes and cable glands<br />
- 850° C for parts of insulating material necessary <strong>to</strong> retain<br />
current carrying parts in position<br />
750° C<br />
V-2<br />
fl ame-retardant<br />
self-extinguishing<br />
Toxic behaviour halogen-free<br />
silicone-free<br />
750° C<br />
V-2<br />
fl ame-retardant<br />
self-extinguishing<br />
-<br />
-<br />
750° C<br />
−<br />
fl ame-retardant<br />
self-extinguishing<br />
<strong>KV</strong> PC <strong>Small</strong><strong>type</strong> distribution<br />
boards<br />
PC polycarbonate<br />
<strong>KV</strong> PC <strong>Small</strong>-<strong>type</strong><br />
distribution<br />
boards<br />
Threaded connecting<br />
glands<br />
AVS 16<br />
The enclosures are suitable for outdoor<br />
installation - harsh environment and /<br />
or outdoor.<br />
The material is examined for UV<br />
resistance by the institute for plastics<br />
and thereby suitable for the outdoor<br />
installation during UV effect.<br />
However the climatic infl uences and<br />
effects on the equipment are <strong>to</strong> be<br />
considered.<br />
+ 35° C<br />
+ 40° C<br />
− 5° C<br />
−<br />
−<br />
960° C<br />
V-2<br />
fl ame-retardant<br />
self-extinguishing<br />
IK08 (5 Joule) IK08 (5 Joule) – IK08 (5 Joule) –<br />
halogen-free<br />
silicone-free<br />
halogen-free<br />
silicone-free<br />
halogen-free<br />
silicone-free<br />
+ 55° C<br />
+ 70° C<br />
− 40° C<br />
−<br />
−<br />
750° C<br />
V-2<br />
fl ame-retardant<br />
self-extinguishing<br />
halogen-free<br />
silicone-free<br />
“Halogen-free” in accordance with IEC 754-2 “Common test methods for cables - Determination of the amount of<br />
halogen acid gas”.<br />
To material properties see technical data.