Setting up a network <strong>connection</strong> between <strong>Scanmax</strong> and DIMENSION<br />

B. <strong>Scanmax</strong> (ScanWare Version 1.30 or higher):<br />

1. BNC Connectors:<br />

<strong>Scanmax</strong>: Replace the terminator with a coax cable with BNC connector.<br />

NT-machine: Connect the other cable's end T-connector to the NT-machine and<br />

don't forget reinstall the terminator on that end.<br />

2. Changes in Scanware.bat in C:\Scanware<br />

Edit SCANWARE.BAT (Caution: blanks are important!); MS-DOS commands:<br />

• CD C:\SCANWARE<br />

• EDIT SCANWARE.BAT<br />

Search for " SCANWARE ". The file must look like this:<br />

:SCANWARE (same setting at section SERVICE, if desired)<br />

GOSUB GEMEINSAM<br />

GOSUB MSCLIENT REM must be removed<br />

REM GOSUP PCTCP<br />

REM GOSUB SCAN_NETZ<br />

C:<br />

CD C:\SCANWARE<br />

SCANWARE.EXE<br />

GOTO ENDE<br />

3. Changes in CAD_LINK.0xx in C:\Scanware\Module<br />

Edit CAD_LINK.0xx (Caution: blanks are important!); MS-DOS commands:<br />

• CD C:\SCANWARE\MODULE<br />

• EDIT CAD_LINK.0xx<br />

Where "0xx" is the country code of the installation. E.g. 049 for Germany. The<br />

following entries must be changed:<br />

ZIELNAME = E:\ (Drive letter „E:\“ for example)<br />

NT = YES<br />

HOLOS = YES<br />

HOLOS_PFAD_NAME = dmis.dmi<br />

4. Create a network <strong>connection</strong><br />

a) Write down the name of the NT-machine<br />

Start Settings Control Panel <strong>Network</strong><br />

In Tab Identifikation you find the computer name.<br />

b) Start <strong>Scanmax</strong> in DOS mode (eventually you have to switch the <strong>Scanmax</strong><br />

computer off and wait 10 seconds before switching it on again; switch off any<br />

connected printer).<br />

c) Start bootnet with these MS-DOS commands<br />

• CD \LOGIN<br />

• Startnet<br />

d) Edit MSCLIENT.BAT (Caution: blanks are important!); MS-DOS commands:<br />

<strong>Scanmax</strong>.doc 2