Setting up a network <strong>connection</strong> between <strong>Scanmax</strong> and DIMENSION<br />
Fehlermeldungen<br />
Error message Possible reasons To resolve the error<br />
<strong>Dimension</strong> error:<br />
CADLINK error No.:14<br />
<strong>Scanmax</strong> error:<br />
Failed to open home file<br />
<strong>Scanmax</strong> error:<br />
Failed to open home file<br />
<strong>Scanmax</strong> error:<br />
Failed to open home file<br />
Holos error:<br />
Failed to open<br />
datafile!<br />
When booting the <strong>Scanmax</strong>machine<br />
the network <strong>connection</strong> to<br />
the NT-machine is not established<br />
properly<br />
When booting the <strong>Scanmax</strong>machine<br />
the network <strong>connection</strong> to<br />
the NT-machine is not established<br />
properly<br />
When booting the <strong>Scanmax</strong>machine<br />
the network <strong>connection</strong> to<br />
the NT-machine is not established<br />
properly<br />
When starting <strong>Scanmax</strong>, an internal<br />
network <strong>connection</strong> is not<br />
established and Scanware counts<br />
from 300 to 0<br />
CAD_LINK.0xx is not configured<br />
correctly<br />
ZIELNAME in CAD_LINK.0xx does<br />
not coincidence with the drive letter<br />
specified in MSCLIENT.BAT<br />
Target directory was not exported<br />
on the NT-machine<br />
The name of the NT-machine was<br />
entered incorrectly in<br />
MSCLIENT.BAT<br />
CAD_LINK.0xx is not configured<br />
correctly<br />
<strong>Network</strong> interfaces and protocols<br />
not correctly installed or user<br />
<strong>Scanmax</strong> was not<br />
Check the settings in<br />
CAD_LINK.0xx<br />
Assign the drive letter used in<br />
MSCLIENT.BAT to the ZILENAME<br />
in CAD_LINK.0xx<br />
Export the target directory on the<br />
NT-machine<br />
Check the NT-machine name and<br />
correct it in MSCLIENT.BAT<br />
Check the Settings in<br />
CAD_LINK.0xx:<br />
HOLOS_PFAD_NAME=dmis.dmi<br />
Check/install network<br />
interfaces/protocolls and check the<br />
user <strong>Scanmax</strong><br />
Power on order was not correct Turn on the NT-machine first and<br />
wait until Windows NT has started,<br />
then boot the <strong>Scanmax</strong>-machine<br />
Hardware <strong>connection</strong> with failures.<br />
Check that you have used a 50Ω<br />
cable and the t-<strong>connection</strong> sits<br />
properly on the network adapter.<br />
<strong>Scanmax</strong> was switched off and on<br />
too quickly or printer wasn't<br />
switched off<br />
Check that you have used a 50Ω<br />
cable and the t-<strong>connection</strong> sits<br />
properly on the network adapter.<br />
Switch off <strong>Scanmax</strong> and printer and<br />
wait 10 seconds before switching it<br />
on again<br />
Please note:<br />
These represent the most common errors. If an error occurs that is not listed here you have to recheck all<br />
settings described in section A and B.<br />
This includes a thorough check of the network settings on the NT-machine. If you get any error messages<br />
concerning the network when booting windows N, you have to correct these before you can continue the<br />
<strong>Scanmax</strong> network <strong>connection</strong> setup.<br />
Eventually the complete network must be reinstalled on the NT-machine. Please consult your NT Administrator<br />
for help on this issue.<br />
<strong>Scanmax</strong>.doc 4