Setting up a network <strong>connection</strong> between <strong>Scanmax</strong> and DIMENSION<br />

Fehlermeldungen<br />

Error message Possible reasons To resolve the error<br />

<strong>Dimension</strong> error:<br />

CADLINK error No.:14<br />

<strong>Scanmax</strong> error:<br />

Failed to open home file<br />

<strong>Scanmax</strong> error:<br />

Failed to open home file<br />

<strong>Scanmax</strong> error:<br />

Failed to open home file<br />

Holos error:<br />

Failed to open<br />

datafile!<br />

When booting the <strong>Scanmax</strong>machine<br />

the network <strong>connection</strong> to<br />

the NT-machine is not established<br />

properly<br />

When booting the <strong>Scanmax</strong>machine<br />

the network <strong>connection</strong> to<br />

the NT-machine is not established<br />

properly<br />

When booting the <strong>Scanmax</strong>machine<br />

the network <strong>connection</strong> to<br />

the NT-machine is not established<br />

properly<br />

When starting <strong>Scanmax</strong>, an internal<br />

network <strong>connection</strong> is not<br />

established and Scanware counts<br />

from 300 to 0<br />

CAD_LINK.0xx is not configured<br />

correctly<br />

ZIELNAME in CAD_LINK.0xx does<br />

not coincidence with the drive letter<br />

specified in MSCLIENT.BAT<br />

Target directory was not exported<br />

on the NT-machine<br />

The name of the NT-machine was<br />

entered incorrectly in<br />

MSCLIENT.BAT<br />

CAD_LINK.0xx is not configured<br />

correctly<br />

<strong>Network</strong> interfaces and protocols<br />

not correctly installed or user<br />

<strong>Scanmax</strong> was not<br />

Check the settings in<br />

CAD_LINK.0xx<br />

Assign the drive letter used in<br />

MSCLIENT.BAT to the ZILENAME<br />

in CAD_LINK.0xx<br />

Export the target directory on the<br />

NT-machine<br />

Check the NT-machine name and<br />

correct it in MSCLIENT.BAT<br />

Check the Settings in<br />

CAD_LINK.0xx:<br />

HOLOS_PFAD_NAME=dmis.dmi<br />

Check/install network<br />

interfaces/protocolls and check the<br />

user <strong>Scanmax</strong><br />

Power on order was not correct Turn on the NT-machine first and<br />

wait until Windows NT has started,<br />

then boot the <strong>Scanmax</strong>-machine<br />

Hardware <strong>connection</strong> with failures.<br />

Check that you have used a 50Ω<br />

cable and the t-<strong>connection</strong> sits<br />

properly on the network adapter.<br />

<strong>Scanmax</strong> was switched off and on<br />

too quickly or printer wasn't<br />

switched off<br />

Check that you have used a 50Ω<br />

cable and the t-<strong>connection</strong> sits<br />

properly on the network adapter.<br />

Switch off <strong>Scanmax</strong> and printer and<br />

wait 10 seconds before switching it<br />

on again<br />

Please note:<br />

These represent the most common errors. If an error occurs that is not listed here you have to recheck all<br />

settings described in section A and B.<br />

This includes a thorough check of the network settings on the NT-machine. If you get any error messages<br />

concerning the network when booting windows N, you have to correct these before you can continue the<br />

<strong>Scanmax</strong> network <strong>connection</strong> setup.<br />

Eventually the complete network must be reinstalled on the NT-machine. Please consult your NT Administrator<br />

for help on this issue.<br />

<strong>Scanmax</strong>.doc 4