5.3 Electrical<br />

Electric connexion only by specialists!!!<br />

The motor is featured with an IP 54 protection. The environmental temperature is only allowed until 40°C. The<br />

used line-cross section averages 5 x 2,5 mm².<br />

The serving electric circuit has to be protected by failure power-protection with a nominal current of IN < 30<br />

mA.<br />

Attention: Using of the pump for swimming-pools and their protected zone is only allowed, if they are<br />

installed after DIN/VDE 0100 component 702. Please ask your electric-specialist.<br />

6. First introduction<br />

Construction only use in filled pools. A dry run has to be avoided.<br />

6.1<br />

It has to be guaranteed that the current entry is inter<strong>mit</strong>tent.<br />

6.2<br />

The intake line and the pump charge slowly with clean water. Otherwise, the pump can not work as powerful as<br />

possible. Don´t let the pump run dry, nor for rotating direction control.<br />

6.3<br />

Before operation after longer downtime or storage time, please control for easy mobility. For this, delete the fan<br />

cover and move the fan towards the rotating direction. Fix the fan cover before starting the motor.<br />

6.4<br />

Please take care for opened shut-off units of the intake- and the pressure side, because the pump is not allowed to<br />

run by closed shut-off units.<br />

6.5<br />

ATTENTION<br />

ATTENTION<br />

ATTENTION<br />

ATTENTION<br />

ATTENTION<br />

Repair the current entry and start the pump.<br />