heateD anD FroSt-proteCteD DrInkerS / heatIng unItS<br />

heated and Frost-protected Drinkers for <strong>Cattle</strong><br />

The following gives you an insight into the <strong>SUEVIA</strong> drinking<br />

bowl program for cattle.<br />

50 years ago already <strong>SUEVIA</strong> started to take care and to<br />

develop heated drinking bowls. Since then our heating systems<br />

have been continuously developed. Today we can offer you for<br />

each intended purpose at least one or even several appropriate<br />

solutions!<br />

Our heated drinking bowls are equipped with a heating<br />

element 24 V, which maintains the drinking bowl frost-free<br />

in winter season. It goes without saying that heated drinking<br />

bowls can only be installed in stables, which dispose of power<br />

supply, provided to a heating element by a transformer. Power<br />

supply cables coming from the transformer towards the<br />

drinking bowl have to be protected against biting! Practice<br />

shows that it is advisable to install the water supply pipe<br />

underground in a frost-free way and to advance upwards to<br />

the drinking bowl. That part of water supply line, which is still<br />

running the risk to freeze, should additionally be wrapped and<br />

protected by a <strong>SUEVIA</strong> frost protection heating cable 24 V.<br />

In free stalls not disposing of electricity, SueVIa thermo<br />

Source drinkers are liked to be used! These drinkers are very<br />

well insulated, which ensures a water supply of your animals<br />

even at extreme low temperatures. The water supply line has<br />

to be placed at a frost-free depth in the ground. ”Earth-warm”<br />

water (in winter season approx. 6°C) runs into the thermo<br />

drinker through the high-capacity float valve installed inside of<br />

the trough. The perfect insulation prevents a drop in temperature<br />

of the water in the drinker and prevents it from freezing.<br />

At minus temperatures it is highly recommended that at least<br />

10 animals use one drinking place.<br />

SueVIa heating units Model 300, 303, 311 and 312 have<br />

been developed for new or modernized stables in which an<br />

underground water supply line is not possible. When using one<br />

of these heating units the water supply line is installed in form<br />

of a water circuit. By means of a circulation pump integrated in<br />

this heating unit the water is pumped through the circuit round<br />

and when needed heated by the installed heating element of<br />

the unit.<br />

<strong>SUEVIA</strong> heating cables are used for water supply line above<br />

ground (see pages 24 - 25).