Catalogue 2012 Cattle S h e e p goatS - SUEVIA HAIGES GmbH
Catalogue 2012 Cattle S h e e p goatS - SUEVIA HAIGES GmbH
Catalogue 2012 Cattle S h e e p goatS - SUEVIA HAIGES GmbH
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
InSIDer tIp!<br />
Keep 24 V cables as short<br />
as possible!<br />
22<br />
heateD anD FroSt-proteCteD DrInkerS / heatIng unItS<br />
Optional: Thermostat for<br />
automatic switch on/off of<br />
transformer (thermostat placed in<br />
the coldest place)<br />
Transformer 230/24 V:<br />
please choose output<br />
according to connected<br />
drinking bowls<br />
Via junction box all drinking bowls<br />
are connected in parallel to the<br />
transformer!<br />
wire cross<br />
section<br />
Installation scheme for heated drinking bowls<br />
Frost-free connection of water line in the ground<br />
24 V<br />
230 V<br />
200 W<br />
24 V<br />
Cable length<br />
see list<br />
below<br />
e.g.<br />
Mod. 46:<br />
24 V, 80 W<br />
total power consumption of heated drinking bowls, incl. additional<br />
heating element + heating cable, connected to one power supply cable<br />
up to 100 watt up to 200 watt up to 300 watt up to 400 watt<br />
1,5 mm² 50 m 25 m 17 m -----<br />
2,5 mm² 83 m 42 m 28 m 21 m<br />
4,0 mm² 132 m 66 m 44 m 33 m<br />
6,0 mm² 200 m 100 m 66 m 50 m<br />
Stable<br />
100 W (110 W) 80 W<br />
{<br />
Heating cable 24 V<br />
2 m: 20 W<br />
(3 m: 30 W)<br />
Max. admitted<br />
cable length<br />
Local norms can vary and have to be checked. Please ensure that a professional electrician installs the system!<br />
{<br />
Installation scheme with optimized view, shown without insulation of pipes. Please ask your dealer for details.<br />
Please read mounting instructions carefuly!<br />
e.g.<br />
Mod. 41A:<br />
24 V, 80 W<br />
Ascending geothermal<br />
energy (keep the<br />
concrete pipe open<br />
from below, do not<br />
cover it with concrete!)