special section<br />
Advertisement<br />
of the new Microlit Bottle Top Dispenser at<br />
AACC completes the liquid-handling range<br />
of micropipette products. These general purpose,<br />
fully autoclavable bottle top dispensers<br />
are suitable <strong>for</strong> a wide range of routine lab<br />
dispensing. CE certified and con<strong>for</strong>ming<br />
to ISO 8655 standards, each dispenser<br />
undergoes strict QC and has an excellent<br />
per<strong>for</strong>mance-to-price ratio.<br />
Microlit<br />
Circle No. 420 in the Reader Service Card<br />
ARCHITECT® ci4100*<br />
Immunochemistry System<br />
The Abbott ARCHITECT® ci4100 system<br />
delivers integration of clinical chemistry<br />
and immunoassay <strong>for</strong> low-to-mid-volume<br />
laboratories with productivity enhancements<br />
normally reserved <strong>for</strong> larger labs. The system<br />
employs identical technologies, reagents, and<br />
software used on the ARCHITECT ci8200®<br />
and ci16200 immunochemistry systems to<br />
provide consistent per<strong>for</strong>mance and comparable<br />
results. The ci4100 uses the innovative<br />
Robotic Sample Handler design to deliver<br />
consistent stat turnaround times while processing<br />
up to 800 chemistry tests and up to<br />
100 immunoassay tests per hour. The ci4100<br />
is an easy-to-use system with a high level of<br />
technical sophistication rarely seen <strong>for</strong> the<br />
low-volume laboratory. * In development.<br />
Abbot Diagnostics<br />
Circle No. 421 in the Reader Service Card<br />
MULTIGENT Creatinine (Enzymatic) Assay*<br />
The MULTIGENT Creatinine (Enzymatic)<br />
assay uses an enzymatic method that is<br />
sensitive and specific <strong>for</strong> creatinine and is not<br />
affected by endogenous substances, such as<br />
ketoacids, cephalosporins, and bilirubin that<br />
interfere with Jaffe methods. The MULTI-<br />
GENT Creatinine (Enzymatic) assay is<br />
standardized to IDMS traceable NIST SRM<br />
967 following the NKDEP, IFCC, and EC4<br />
recommendation promoting the use of commutable<br />
reference material. Standardization<br />
and accuracy of serum creatinine measurements<br />
are critical <strong>for</strong> the estimation of renal<br />
function using the glomerular filtration rate<br />
(eGFR) equation. *Pending FDA clearance.<br />
Available outside the U.S.<br />
Abbott Diagnostics<br />
Circle No. 422 in the Reader Service Card<br />
36 CliniCal laboratory news JuLy 2008<br />
2008 NEw Pr o d u c t rE v i E w<br />
BioLis 24i Chemistry Analyzer<br />
The new Carolina Chemistries BioLis 24i<br />
analyzer is a 400-test/hour, bench-top<br />
chemistry analyzer. With a menu of more<br />
than 100 chemistries, it serves well as a<br />
backup analyzer <strong>for</strong> hospitals that can’t af<strong>for</strong>d<br />
to be down. Requiring only 31 inches<br />
of bench space, this instrument is also ideal<br />
as a primary analyzer <strong>for</strong> small hospitals and<br />
physician office laboratories where space is a<br />
consideration.<br />
Carolina Liquid Chemistries<br />
Circle No. 423 in the Reader Service Card<br />
ST AIA-PACk cTnI 3rd-Gen Assay*<br />
The new ST AIA-PACK cTnI 3rd-Gen assay<br />
is designed <strong>for</strong> in vitro diagnostic use <strong>for</strong> the<br />
quantitative measurement of cardiac troponin<br />
I (cTnI) on TOSOH AIA system analyzers.<br />
Cardiac troponin I measurements are used<br />
as an aid in the diagnosis of acute myocardial<br />
infarction. *Pending FDA clearance.<br />
TOSOH BIOSCIENCE, INC.<br />
Circle No. 424 in the Reader Service Card<br />
AIA-PACk RBC FOLATE Assay*<br />
The new AIA-PACK RBC FOLATE assay is<br />
designed <strong>for</strong> in vitro diagnostic use <strong>for</strong> the<br />
quantitative measurement of RBC folate<br />
in whole-blood samples on TOSOH AIA<br />
system analyzers. Although serum folate<br />
offers a reliable test, it fluctuates in serum<br />
based on dietary changes. RBC folate, however,<br />
does not become depleted as quickly<br />
as serum folate, and is much more concentrated<br />
in serum. RBC folate concentration<br />
correlates well with other indices of folate<br />
deficiency, such as bone-marrow cell morphology<br />
and hematological changes, making<br />
RBC folate concentration a reliable indicator<br />
of folate status. *Pending FDA clearance.<br />
TOSOH BIOSCIENCE, INC.<br />
Circle No. 425 in the Reader Service Card<br />
Automated Glycohemoglobin<br />
Analyzer HLC-723G8*<br />
The Automated Glycohemoglobin Analyzer<br />
HLC-723G8 is the next generation HbA1c<br />
monitoring system from Tosoh Bioscience.<br />
With a fast analysis time of 1.6 minutes<br />
and direct determination of SHbA1c with<br />
less than 2% CV, the G8 provides the high<br />
level of speed and reliability that labs have<br />
come to expect from Tosoh products. The<br />
extremely compact G8 is about 20 inches in<br />
width, depth, and height and weighs only 75<br />
lbs. Automated maintenance, simple operation,<br />
and a host of time-saving features all<br />
combine to make the G8 analyzer a highly<br />
evolved and efficient solution <strong>for</strong> HPLC testing.<br />
*Pending FDA clearance.<br />
TOSOH BIOSCIENCE, INC.<br />
Circle No. 426 in the Reader Service Card<br />
UVA-Enhanced HPX® Halogen Lamps<br />
Introducing a new category of highly<br />
stable, UVA-enhanced lamps to Welch Allyn<br />
Lighting’s HPX miniature halogen product<br />
family. The lamps are available in wattages<br />
ranging from 5W to 20W, and their output<br />
extends from the 300- to 400-nm UV range<br />
into the near IR while retaining full spectral<br />
output. Bright, small, and efficient, these<br />
highly stable sources exhibit 0.05% or less<br />
output variation. Our UVA-enhanced<br />
HPX lamps enable next-generation devices,<br />
such as low-cost, POC, and portable analytical<br />
equipment. To best meet each customer’s<br />
requirements, our engineering team customizes<br />
wattage, output, lamp life, spectral<br />
characteristics, reflectors, bases, and optics.<br />
Welch Allyn Lighting<br />
Circle No. 427 in the Reader Service Card<br />
Genesys Neonatal Hb<br />
Variant Screening System<br />
Trinity Biotech introduces the Primus<br />
GeneSys Neonatal Hb Variant Screening<br />
System, the first on the market to offer a fully<br />
automated approach <strong>for</strong> newborn screening<br />
while providing positive detection of key<br />
hemoglobin variants. Our new 2-minute<br />
HPLC neonatal assay provides automated<br />
sample handling, sample preparation, sample<br />
reporting, confirmatory analysis, cleanup,<br />
and shutdown. The system also automatically<br />
runs an 8-minute confirmation on<br />
the same instrument <strong>for</strong> all positive results<br />
detecting S, C, D, E, O, and Bart’s variants,<br />
plus many more hemoglobin variants. The<br />
GeneSys Neonatal Hb Variant Assay is one<br />
of three assays available on the Primus ultra2<br />
plat<strong>for</strong>m.<br />
Trinity Biotech<br />
Circle No. 428 in the Reader Service Card<br />
TRI-stat POC A1c Analyzer<br />
Trinity Biotech introduces the new POC<br />
TRI-stat instrument and A1care reagent kit<br />
<strong>for</strong> interference-free HbA1c testing. Small<br />
and portable <strong>for</strong> office-to-office use, the<br />
analyzer’s features include boronate affinity<br />
technology, three tests in 10 minutes,