05.06.2013 Views

Enclosed Conductor System MKH

Enclosed Conductor System MKH

Enclosed Conductor System MKH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MKH</strong>D/<strong>MKH</strong>F/<strong>MKH</strong>S<br />

Collectors<br />

Single collector MSWAS<br />

upto max. 250 m/min.<br />

In conductor rails with sealing strip upto 100 m/min.<br />

Connecting cables:<br />

for power line: cable 1 → 4 x 6 mm 2<br />

cable 2 → … x 1,5 mm 2<br />

for control line: cable 1 → … x 2,5 mm 2<br />

(two cables for 8-pole and more)<br />

Example of ordering double collectors with 2 m cable<br />

Oder - No. 236 000-2<br />

for collector MSWA 6/50-2 HS<br />

For curves use single collectors only.<br />

Connecting cable 1 m, longer cable available<br />

Type Weight kg No. of<br />

conductors<br />

Power rating<br />

at 60% DC<br />

ø of connecting-cables in mm Order - No.<br />

Cable 1 Cable 2<br />

MSWAS 6 / 50 - 1 HS 1,178 6 50 ≈ 17,0 ≈ 7,0 236 200<br />

MSWAS 7 / 50 - 1 HS 1,203 7 50 ≈ 17,0 ≈ 7,5 236 201<br />

MSWAS 8 / 50 - 1 HS 1,241 8 50 ≈ 17,0 ≈ 8,0 236 202<br />

MSWAS 9 / 50 - 1 HS 1,420 9 50 ≈ 17,0 ≈ 9,0 236 203<br />

MSWAS 10 / 50 - 1 HS 1,500 10 50 ≈ 17,0 ≈ 9,5 236 204<br />

MSWAS 6 / 25 - 1 ST 0,902 6 25 ≈ 11,5 - 236 205<br />

MSWAS 7 / 25 - 1 ST 0,912 7 25 ≈ 11,5 - 236 206<br />

MSWAS 8 / 25 - 1 ST 0,956 8 25 ≈ 10,0 ≈ 10,0 236 207<br />

MSWAS 9 / 25 - 1 ST 1,149 9 25 ≈ 11,0 ≈ 10,0 236 208<br />

MSWAS 10 / 25 - 1 ST 1,275 10 25 ≈ 11,5 ≈ 10,0 236 209<br />

28<br />

152<br />

335<br />

Cable 1 Cable 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!