2. List of simulation codes<br />

Main Sub Functions Section<br />

1 1 Used to check the operation of the scanner (reading) unit and the control circuit. Scanner (reading)<br />

2 Used to check the sensors in the scanner (reading) section and the related circuits. Scanner (reading)<br />

5 Used to check the operation of the scanner (reading) unit and the control circuit. Scanner (reading)<br />

2 1 Used to check the operations of the auto document feed unit and the control circuit. RSPF/DSPF<br />

2 Used to check the operations of the sensors and the detectors in the document feed unit section and the<br />

control circuits.<br />

RSPF/DSPF<br />

3 Used to check the operations of the loads in the auto document feed unit and the control circuit. RSPF/DSPF<br />

3 2 Used to check the operations of the sensors and the detectors in the finisher and the control circuit. Finisher<br />

3 Used to check the operation of the load in the finisher and the control circuit. Finisher<br />

10 Used to adjust the finisher. Finisher<br />

4 2 Used to check the operations of the sensors and detectors in the desk/large capacity tray, and the control<br />

circuit of those.<br />

Desk/Large capacity tray (LCC)<br />

3 Used to check the operations of the loads in the desk/large capacity tray (LCC), and the control circuit of<br />

those.<br />

Desk/Large capacity tray (LCC)<br />

5 Used to check the operations of the paper feed desk paper transport clutch (DTRC) and the LCC paper<br />

transport clutch (LTRC).<br />

<strong>MX</strong>-<strong>5001N</strong> SIMULATION 6 – 3<br />

Paper feed desk/<br />

Large capacity tray (LCC)<br />

5 1 Used to check the operation of the display, LCD in the operation panel, and control circuit. Operation panel<br />

2 Used to check the operation of the heater lamp and the control circuit. Fusing<br />

3 Used to check the operation of the scanner lamp and the control circuit. Scanner (reading)<br />

4 Used to check the operation of the discharge lamp and the control circuit. Process<br />

6 1 Used to check the operations of the load in the paper transport system (clutches and solenoids) and the<br />

control circuits.<br />

Paper transport/Paper exit section<br />

2 Used to check the operations of each fan motor and its control circuit. Others<br />

3 Used to check the operations of the primary transport unit and the control circuit. Process (Transport)<br />

6 Used to check the operation of the fusing separation. Fusing<br />

7 1 Used to set the operating conditions of aging. Others<br />

6 Used to set the operating intermittent aging cycle.<br />

8 Used to display the warm-up time.<br />

9 Color setting in the color copy test mode (Used to check the copy operation and the image quality for each<br />

color).<br />

12 The document reading number of sheets setting (for aging operation) RSPF/DSPF<br />

8 1 Used to check and adjust the operations of the developing voltage in each print mode and the control<br />

circuit.<br />

* When the middle speed is adjusted, the low speed are also adjusted simultaneously.<br />

Process (Developing)<br />

2 Used to check and adjust the operation of the main charger grid voltage in each printer mode and the<br />

control circuit.<br />

* When the middle speed is adjusted, the low speed are also adjusted simultaneously.<br />

Process (Charging)<br />

6 Used to check and adjust the operation of the transport voltage and the control circuit. Process (Transport)<br />

9 2 Used to check the operations of the sensors and detectors in the paper reverse section (duplex section)<br />

and its control circuit.<br />

Duplex<br />

3 Used to check the operations of the load in the paper reverse section (duplex section) and its control<br />

circuit.<br />

Duplex<br />

10 1 Used to check the operations of the toner supply mechanism (toner motor) and the related circuit. Process (Developing)<br />

13 - Used to cancel the self-diag "U1" trouble.<br />

14 - Used to cancel excluding the self-diag U1/U2/LCC/PF troubles.<br />

15 - Used to cancel the self-diag "U6-09" (large capacity paper feed tray) trouble. LCC<br />

16 - Used to cancel the self-diag "U2" trouble. MFP PWB / PCU PWB / SCU PWB<br />

17 - Used to cancel the self-diag "PF" trouble.<br />

21 1 Used to set the maintenance cycle.<br />

22 1 Used to check the print count value in each section and each operation mode. (Used to check the<br />

maintenance timing.)<br />

2 Used to check the total number of misfeed and troubles. (When the number of total jam is considerably<br />

great, it is judged as necessary for repair.)<br />

3 Used to check misfeed positions and the misfeed count of each position. * Presumption of the faulty point<br />

by this data is possible.<br />

4 Used to check the trouble (self diag) history.<br />

5 Used to check the ROM version of each unit (section). Firmware<br />

6 Used to output the setting/adjustment data (simulation, FAX soft switch, counter), the firmware version,<br />

and the counter list.<br />

8 Used to check the number of operations (counter value) of the finisher, the RSPF, and the scan (reading)<br />

unit.<br />

9 Used to check the number of use (print quantity) of each paper feed section. Paper feed, ADU, LCC<br />

10 Used to check the system configuration (option, internal hardware).<br />

11 Used to check the use frequency (send/receive) of FAX. (Only when FAX is installed) FAX<br />

12 Used to check the RSPF/DSPF misfeed positions and the number of misfeed at each position. (When the<br />

number of misfeed is considerably great, it can be judged as necessary for repair.)<br />

RSPF/DSPF<br />

13 Used to check the operating time of the process section (OPC drum, DV unit, toner cartridge). Process<br />

19 Used to check the values of the counters related to the scan - image send.<br />

90 Used to output the various set data lists.