7.2. Mounting instructions for telescopic forks with a separate flow divider<br />
(RE2, RE4, REE2 and REE4)<br />
To achieve the most optimal operation of your telescopic forks after the mounting you should observe<br />
the following mounting instructions:<br />
1. On the type plates of the telescopic forks there are an L and an R displayed. Mount these<br />
telescopic forks accordingly on the right and on the left sides viewed from the position of the fork-<br />
lift truck driver.<br />
2. Slide the telescopic forks onto the fork carrier and make sure that the locking pin fits into one of<br />
the fork carrier notches.<br />
3. The flow divider must be mounted on a safe and protected spot.<br />
4. Connect the enclosed hydraulic hoses of the telescopic forks and the hoses of the fork-lift truck<br />
according to Figure 7.1 and pay attention to the letters that are engraved at the top of the fork as<br />
well as in the flow divider.<br />
5. Make sure that the hydraulic connections are carefully tightened and secured.<br />
6. The maximum allowable working pressure of the telescopic forks is 200 bars.<br />
Figure 7.1 A depiction of how the hydraulic hoses for telescopic forks with a separate flow divider must be connected<br />