<strong>Rittal</strong> <strong>–</strong> <strong>The</strong> <strong>System</strong>.<br />

Faster <strong>–</strong> better <strong>–</strong> worldwide.<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

1<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

GIUSEPPE LETO / Product Manager Divisione IT<br />

1<br />

PM-Version 1.0


RITTAL nel mondo oggi<br />

• <strong>Rittal</strong> è leader mon<strong>di</strong>ale nella fabbricazione e commercializzazione<br />

<strong>di</strong> arma<strong>di</strong> per quadri <strong>di</strong> comando, <strong>di</strong> contenitori per elettronica, <strong>di</strong><br />

soluzioni <strong>di</strong> climatizzazione, <strong>di</strong> soluzioni per la <strong>di</strong>stribuzione <strong>di</strong><br />

corrente e <strong>di</strong> soluzioni per l’INFORMATION TECHNOLOGY e le<br />

TELECOMUNICAZIONI<br />

• Presente in tutto il mondo con più <strong>di</strong> 70 filiali in altrettanti paesi<br />

• Consolidato <strong>di</strong> oltre 1,6 Billions Euro<br />

• Oltre 10.000 <strong>di</strong>pendenti a livello worldwide<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

2<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

Speaker / Department / Date<br />

2<br />

PM-Version 1.0


RITTAL nel mondo oggi<br />

• Arma<strong>di</strong> per automazione industriale<br />

• Sistemi e cestelli per l‘elettronica<br />

• Sistemi <strong>di</strong> con<strong>di</strong>zionamento<br />

• Sistemi <strong>di</strong> <strong>di</strong>stribuzione per l‘energia<br />

• Soluzioni modulari per il mercato IT: a 360 gra<strong>di</strong> per le infrastrutture<br />

CED GREEN DATA CENTER<br />

• Sistemi per le telecomunicazioni<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

3<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

Speaker / Department / Date<br />

3<br />

PM-Version 1.0


<strong>Rittal</strong> <strong>–</strong> <strong>The</strong> <strong>System</strong>.<br />

Product overview<br />

Modular enclosure<br />

systems<br />

• Enclosure systems<br />

• Small enclosures<br />

• Command Panel &<br />

support arm systems<br />

• Console systems<br />

• Stainless steel &<br />

industry solutions<br />

• Network &<br />

server enclosures<br />

• IT wall-mounted enclosures<br />

• Outdoor enclosures<br />

INDUSTRIAL ENCLOSURES<br />

<strong>System</strong> climate<br />

control<br />

• Roof-mounted & wallmounted<br />

cooling units<br />

• Recooling systems<br />

• Air/air or air/water heat<br />

exchangers<br />

• Fan systems<br />

• Enclosure heaters<br />

POWER DISTRIBUTION<br />

Power <strong>di</strong>stribution<br />

systems<br />

• Modular kit for lowvoltage<br />

switchgear<br />

up to 5,500 A<br />

• 60mm system<br />

technology power<br />

<strong>di</strong>stribution and controls<br />

up to 1,600A<br />

Fully compatible system accessories<br />

Software<br />

Services<br />

IT systems<br />

• Integrated DC<br />

solutions<br />

• Consultancy, planning<br />

structural design<br />

• Physical security<br />

• UPS systems<br />

• IT climate control<br />

• Monitoring systems<br />

ELECTRONIC PACKAGING<br />

4<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

4<br />

PM-Version 1.0


<strong>Rittal</strong> <strong>–</strong> <strong>The</strong> <strong>System</strong>.<br />

Target sectors<br />

Mechanical engineering<br />

Electrical design<br />

Infrastructure<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

Food & consumables<br />

Transport technology<br />

Alternative energy forms<br />

ITC<br />

Buil<strong>di</strong>ng infrastructure<br />

Process industry<br />

ELECTRONIC PACKAGING<br />

5<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

5<br />

PM-Version 1.0


<strong>Rittal</strong> oggi ...le competenze nel mondo IT<br />

1. Market leader OEM IT enclosure server systems<br />

2. IT & Networking infrastructure systems<br />

3. Turn Key infrastructure solutions<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

6<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

Speaker / Department / Date<br />

www.rimatrix5.com<br />

FujitsuSiemens<br />

6<br />

PM-Version 1.0


GREEN COMPUTING : Soluzioni innovative per<br />

la sicurezza e l‘efficenza energetica dei Data<br />

Center .<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

7<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

Speaker / Department / Date<br />

7<br />

PM-Version 1.0


Data Center Efficiency<br />

L’infrastruttura del data center<br />

UPS systems<br />

1-18 kVA, 1-phase<br />

10 <strong>–</strong> 960 kW, 3-phase<br />

Power<br />

<strong>di</strong>stribution<br />

Fully wired and<br />

contact hazard proof<br />

IT recooling<br />

systems<br />

Holistic solutions for<br />

IT cooling<br />

Pipework<br />

Optimum<br />

design<br />

INDUSTRIAL ENCLOSURES<br />

Security rooms<br />

Protection against a<br />

large number of physical<br />

hazards<br />

POWER DISTRIBUTION<br />

RiZone<br />

Manages and monitors the<br />

entire data centre<br />

Room, raised<br />

floor,<br />

rack cooling<br />

In<strong>di</strong>vidual cooling<br />

concepts<br />

Server racks<br />

A large range<br />

with comprehensive<br />

accessories<br />

Network<br />

enclosures<br />

Network enclosures<br />

IT wall-mounted<br />

enclosures<br />

Sensor network<br />

monitoring<br />

Optimum availability<br />

& transparency<br />

ELECTRONIC PACKAGING<br />

10<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

10<br />

PM-Version 1.0


Data Center Efficiency<br />

Product overview <strong>–</strong> SICUREZZA FISICA IT - SOLUZIONI IGNIFUGHE<br />

Micro data centre<br />

• <strong>The</strong> smallest security solution:<br />

15 U, turn-key,<br />

inclu<strong>di</strong>ng physical security<br />

• Incl. climate control concept<br />

INDUSTRIAL ENCLOSURES<br />

Mini data centre<br />

POWER DISTRIBUTION<br />

Internal requirements<br />

• Data loss / replacement cost<br />

• EDP failure / economic loss<br />

• Energy-efficient climate control<br />

• Economic espionage / loss of know-how<br />

• Accidents / fire / arson<br />

• <strong>The</strong>ft / sabotage / manipulation<br />

• Monitoring and extinguisher system<br />

• Modular UPS and power <strong>di</strong>stribution<br />

Physical protection against threats like<br />

fire, water, smoke gases and burglary<br />

Data Centre Container<br />

• Temporary outdoor data centre<br />

during conversions, extension or<br />

relocations<br />

• Energy efficiency through <strong>di</strong>rect free<br />

cooling (PUE less than 1.2)<br />

• Provides space for 329 U<br />

Legislation / <strong>di</strong>rectives<br />

• Federal Data Protection Act<br />

• EU legislation / Product liability law<br />

• Quality assurance systems: ISO 9001/<br />

ISO 27001<br />

• Expert guidelines (VdS in Germany)<br />

• Basel II, Solvency II and Sarbanes-Oxley Act<br />

Data centre<br />

• Physical security:<br />

From high availability to basic<br />

protection<br />

• Requirement-oriented package with<br />

energy-efficient infrastructure<br />

ELECTRONIC PACKAGING<br />

11<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

11<br />

PM-Version 1.0


Data Center Efficiency<br />

Technical Workstation and Fire-proof Safes for IT back-up<br />

Dis Data Safes<br />

• Complete flexibility for securing me<strong>di</strong>a:<br />

+ Magnetic tapes<br />

+ Optical data carrier (CD, DVD)<br />

+ Hard drive<br />

+ Diskettes<br />

+ Paper documents<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

Data Back-up<br />

• Unprotected data inventories can mean<br />

very large losses for companies and<br />

authorities in the case of damage<br />

• Modern data carriers such as CDs, DVDs,<br />

magnetic tapes, streamer or giga-tapes<br />

concentrate critical information on a very<br />

small space<br />

• <strong>The</strong>se data carriers can be destroyed or<br />

stolen through fire or third-party access<br />

IT Modular Workstation<br />

• Spectro-Data <strong>–</strong><br />

the unique modular kit system<br />

for technical workstations<br />

with boundless possibilities<br />

Technical Workstation<br />

• Spectro-Data Vision realises the systematic<br />

integration of IT and communication units for<br />

the workstations of our customers<br />

ELECTRONIC PACKAGING<br />

12<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

12<br />

PM-Version 1.0


Sostenibilità dell’investimento<br />

Il Data-Centre deve essere Green, ma soprattutto deve garantire competitività<br />

“Le esigenze elaborative sono in aumento e le aziende che<br />

possiedono centri dati dovranno stare al passo adottando le nuove<br />

tecnologie. Una ricerca Coleman Parkes commissionata da HP fa<br />

luce sulle sfide dei CIO, tra costi, efficienza e coscienza verde”<br />

(Il sole 24 ore)<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

La competitività <strong>della</strong> mia<br />

azienda <strong>di</strong>pende sempre<br />

<strong>di</strong> più dall’informatica.<br />

Devo conciliare la server<br />

consolidation, la<br />

virtualizzazione e<br />

l’aumento <strong>della</strong> richiesta<br />

<strong>di</strong> capacità elaborativa<br />

riducendo i costi! Come?<br />

ELECTRONIC PACKAGING<br />

14<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

14<br />

PM-Version 1.0


Virtualizzazione<br />

Offre enormi vantaggi ma necessita un adeguamento dell’infra\struttura<br />

INDUSTRIAL ENCLOSURES<br />

- Più carichi <strong>di</strong> lavoro su un numero ridotto <strong>di</strong> server (Consolidamento)<br />

- Riduzione costi e incremento produttività (Automazione ciclo <strong>di</strong> vita)<br />

- Miglioramento dell’affidabilità e <strong>della</strong> <strong>di</strong>sponibilità (Business Continuity)<br />

- Miglioramento <strong>della</strong> gestione <strong>della</strong> sicurezza (Sicurezza e gestione)<br />

- Riduzione del consumo energetico (Risparmio energetico)<br />

- Miglioramento <strong>della</strong> competitività (TCO)<br />

POWER DISTRIBUTION<br />

Grazie alla<br />

virtualizzazione posso<br />

ottenere innumerevoli<br />

vantaggi ma la mia<br />

infrastruttura non mi<br />

consente <strong>di</strong> poterne<br />

usufruire in quanto non<br />

posso far fronte<br />

all’aumento <strong>di</strong> densità!<br />

ELECTRONIC PACKAGING<br />

15<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

15<br />

PM-Version 1.0


Impianto elettrico<br />

La concentrazione <strong>di</strong> potenza sarà un problema per oltre il 50% dei CIO<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

L’utilizzo <strong>di</strong> macchine<br />

virtuali richiede una<br />

maggiore potenza<br />

concentrata in uno<br />

spazio ridotto. Il mio<br />

impianto elettrico non è<br />

adeguato!<br />

ELECTRONIC PACKAGING<br />

16<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

16<br />

PM-Version 1.0


Impianto <strong>di</strong> raffreddamento<br />

I sistemi tra<strong>di</strong>zionali non sono più adeguati<br />

Oltre l’80% dei CIO dovrà affrontare il problema dei propri Data-<br />

Centre che non sono adeguati per garantire un raffreddamento<br />

idoneo a consentirne l’espansione<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

L’utilizzo <strong>di</strong> macchine<br />

virtuali mi ha permesso<br />

<strong>di</strong> ottenere ottimi risultati<br />

ma il mio impianto <strong>di</strong><br />

raffreddamento non è<br />

adeguato per gestire la<br />

concentrazione e<br />

l’aumento <strong>di</strong> densità!<br />

ELECTRONIC PACKAGING<br />

17<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

17<br />

PM-Version 1.0


Data Center Efficiency<br />

Strumenti <strong>di</strong> misura<br />

PUE / DCiE by "<strong>The</strong> Green Grid"<br />

• PUE = Power Usage<br />

Effectiveness<br />

<strong>–</strong> Rapporto tra potenza<br />

assorbita e potenza erogata al<br />

carico<br />

• DCiE = Data Center index of<br />

Efficiency<br />

<strong>–</strong> Reciproco del PUE<br />

<strong>–</strong> Tende ad 1 quanto più è<br />

efficiente il sistema<br />

• Ambiti <strong>di</strong> intervento<br />

<strong>–</strong> Power<br />

<strong>–</strong> Cooling<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

PUE DCiE<br />

3.0 33%<br />

Livello <strong>di</strong><br />

Efficienza<br />

Molto<br />

inefficiente<br />

2.5 40% Inefficiente<br />

2.0 50% Me<strong>di</strong>o<br />

1.5 67% Efficiente<br />

1.2 83% Molto efficiente<br />

ELECTRONIC PACKAGING<br />

19<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

19<br />

PM-Version 1.0


Data Center Efficiency<br />

Strumenti <strong>di</strong> misura<br />

PUE / DCiE by "<strong>The</strong> Green Grid"<br />

rappresenta le per<strong>di</strong>te <strong>di</strong> carico calcolate sulla linea elettrica (dalla cabina al carico);<br />

rappresenta la potenza assorbita dall’impianto <strong>di</strong> illuminazione;<br />

rappresenta gli assorbimenti elettrici <strong>degli</strong> impianti speciali (antincen<strong>di</strong>o);<br />

rappresenta gli assorbimenti elettrici dell’infrastruttura IT (server, storage, switch);<br />

rappresenta l’efficienza energetica dell’UPS (variabile in funzione del carico);<br />

rappresenta la potenza assorbita dai compressori e dalle pompe dal chiller (tiene conto del beneficio<br />

indotto dalla batteria free cooling durante le ore in cui la temperatura esterna è <strong>di</strong> 2°C inferiore a quella<br />

del liquido nel circuito <strong>di</strong> ritorno);<br />

rappresenta la potenza assorbita dalle unità <strong>di</strong> raffreddamento - LCP, umi<strong>di</strong>ficatori, split - durante il loro<br />

funzionamento (valore me<strong>di</strong>o).<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

20<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

20<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

<strong>The</strong> <strong>System</strong> in the industry <strong>–</strong> IT system applications<br />

<strong>Rittal</strong>'s services encompasses the entire<br />

IT infrastructure <strong>–</strong> from small-sized network<br />

<strong>di</strong>stributors to high-security data centres:<br />

• IT enclosure solutions<br />

• Power <strong>di</strong>stribution and back-up<br />

• Efficient climate control<br />

• Security solutions<br />

• Management & monitoring<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

21<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

21<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

Product overview <strong>–</strong> IT enclosure and housing solutions<br />

INDUSTRIAL ENCLOSURES<br />

Network enclosures Server racks<br />

Network <strong>di</strong>stributors for industrial<br />

environments Network <strong>di</strong>stributor for office environments Space-saving network <strong>di</strong>stributors<br />

POWER DISTRIBUTION<br />

Extensive range of system accessories<br />

ELECTRONIC PACKAGING<br />

22<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

22<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

TS 8 network enclosure<br />

Facts and features:<br />

+ <strong>The</strong> right system for the right application:<br />

From floor <strong>di</strong>stributors to data centres<br />

+ Unlimited options for cable management<br />

+ Comprehensive system accessories to deal with all<br />

network-related tasks<br />

Saves time by ...<br />

• Making assembly work easier and quicker with<br />

comprehensive TS accessories<br />

• Selecting products easily with the IT configurator<br />

• Having products ready for use due to pre-configured<br />

designs ex-stock<br />

$ Saves cost by ...<br />

• Benefiting from the long service life of the TS 8 system<br />

• Making reliable investments: scalable and suitable<br />

retrospective conversions<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

23<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

23<br />

PM-Version 1.0


Power <strong>di</strong>stribution<br />

IT power <strong>di</strong>stribution and back-up<br />

Low-voltage main<br />

<strong>di</strong>stributor with Ri4Power<br />

• Busbar systems up to 5,500 A for<br />

in<strong>di</strong>vidual configurations<br />

• Integrates measuring systems<br />

for <strong>di</strong>fferent works<br />

INDUSTRIAL ENCLOSURES<br />

Power back-up with the<br />

UPS system PMC<br />

• Rack-mounted, modular design<br />

• Scalable up to 960 kW<br />

• Highly efficient, with 95% energy<br />

conversion efficiency in the partial<br />

load range already<br />

POWER DISTRIBUTION<br />

Power sub-<strong>di</strong>stribution<br />

with PDR and PDM<br />

• Modular construction; can be<br />

extended with the system<br />

operational<br />

• Phase current up to 250 A at the<br />

input; VDE-certified<br />

• Shock-hazard protected<br />

Power <strong>di</strong>stribution inside<br />

the rack with PSM<br />

• Plug and play power supply<br />

• Modules with <strong>di</strong>fferent<br />

sockets<br />

• Manageable modules with current<br />

measuring and switching functions<br />

ELECTRONIC PACKAGING<br />

24<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

24<br />

PM-Version 1.0


UPS<br />

Modulari, scalabili a caldo<br />

PMC 12<br />

1 <strong>–</strong> 18 kVA<br />

• Compact, 1-phase UPS<br />

• Scalable autonomy<br />

Up to 55 min. at 100% load<br />

• Optional monitoring via<br />

web browser<br />

Saves time by ... Making maintenance work easier and quicker whilst the system is operational due to a rack-mounted,<br />

modular system<br />

$ Saves cost by ... High-level efficiency and scalability in line with requirements<br />

INDUSTRIAL ENCLOSURES<br />

PMC 40<br />

10 <strong>–</strong> 40 kW<br />

• Rack-independent, 3-phase UPS<br />

• Redundant system for<br />

maximum availability<br />

• Mixed population e.g. with<br />

servers in the same rack also<br />

supported<br />

POWER DISTRIBUTION<br />

PMC 200<br />

8 <strong>–</strong> 800 kW<br />

• High level of efficiency: 95%<br />

• Flexible, almost unlimited<br />

scalability and redundancy.<br />

• Less capital tie-up,<br />

may be expanded thanks to its<br />

modularity<br />

PMC 800<br />

64 <strong>–</strong> 960 kW<br />

• Maximum availability and<br />

performance in a modular design<br />

• Service-friendly because modules<br />

are <strong>di</strong>vided into a power<br />

and a control module<br />

ELECTRONIC PACKAGING<br />

25<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

25<br />

PM-Version 1.0


UPS<br />

Confronto con sistemi stand-alone<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

26<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

26<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

PDR <strong>–</strong> Power Distribution Rack<br />

Facts and features:<br />

+ Power <strong>di</strong>stribution rack designed to accommodate up to 8<br />

Power Distribution Modules (PDM)<br />

+ 4 racks (PSM busbars) may be connected to each PDM<br />

module<br />

+ Simple installation and expansion while operational due to<br />

complete contact hazard protection<br />

+ Pre-configured cables also available in special lengths<br />

Saves time by ...<br />

• Easy to expand without the help of<br />

trained personnel, even whilst the system is operational<br />

• Quick to service thanks to its modular design<br />

$ Saves cost by ...<br />

• Minimising installation costs due to plug & play<br />

technology<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

27<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

27<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

PSM<br />

Facts and features:<br />

+ Modular power <strong>di</strong>stribution in IT racks<br />

+ 3-phase system with redundant power supply (A/B)<br />

up to 192 A<br />

+ Plug-in modules with <strong>di</strong>fferent sockets,<br />

(e.g. C13 / C19) and country versions<br />

+ Modules that can be actively managed, inclu<strong>di</strong>ng current<br />

measuring and switching functions down to in<strong>di</strong>vidual<br />

outputs<br />

Saves time by ...<br />

• Facilitating module replacement during service works or<br />

expansion while the system is operational<br />

$ Saves cost by ...<br />

• Ensuring a redundant power supply in a single busbar<br />

• Facilitating integration into <strong>Rittal</strong>'s IT racks<br />

• Saving valuable height units inside the rack<br />

• Using the remote management function via IP<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

28<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

28<br />

PM-Version 1.0


Cooling<br />

IT climate control<br />

Rack-based cooling<br />

• High-performance cooling with<br />

up to 30 kW / rack<br />

• High energy efficiency<br />

INDUSTRIAL ENCLOSURES<br />

Suite-based cooling<br />

• Cooling system integrated into<br />

the enclosure suite<br />

• Efficiency can be increased with<br />

optional aisle containment systems<br />

• Raised floor not required<br />

POWER DISTRIBUTION<br />

Room-based cooling<br />

• Cooling output up to 118 kW<br />

• Efficiency can be increased with<br />

optional aisle containment systems<br />

• Optimised energy and<br />

room efficiency<br />

IT chiller &<br />

Piping systems<br />

• Cooling output from 8.5 to<br />

462 kW<br />

• Redundant pump design<br />

• Optimised COP value<br />

• Inexpensive plastic pipework<br />

ELECTRONIC PACKAGING<br />

29<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

29<br />

PM-Version 1.0


Cooling<br />

Sistemi <strong>di</strong> raffreddamento per tutte le esigenze<br />

Basic solutions<br />

CRAC system<br />

with aisle containment system<br />

LCP Inline<br />

with aisle containment system<br />

LCP Smart<br />

LCP Plus<br />

LCP T3+, fully redundant<br />

Low Density Mid Density High Density<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

30kW<br />

Output /<br />

rack:<br />

ELECTRONIC PACKAGING<br />

30<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

30<br />

PM-Version 1.0


Climate control<br />

<strong>System</strong> applications: IT<br />

<strong>System</strong> applications in data centres: Rack cooling and room air-con<strong>di</strong>tioning<br />

Liquid Cooling Packages Aisle containment CRAC system<br />

<strong>System</strong> applications in data centres and buil<strong>di</strong>ng services: Server climate control<br />

and free cooling<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

Cooling required for:<br />

•Rack climate control<br />

•Room climate control<br />

•Server suites<br />

<strong>Rittal</strong> climate control solutions used:<br />

•Liquid Cooling Packages<br />

•Aisle containment<br />

•CRAC systems<br />

Cooling required for:<br />

•Data centre<br />

•Buil<strong>di</strong>ng services room<br />

<strong>Rittal</strong> climate control solutions used:<br />

•Liquid Cooling Packages<br />

•IT chillers with free cooling function<br />

•Intelligent control systems<br />

Typical: 5 -10 kW per enclosure<br />

ELECTRONIC PACKAGING<br />

31<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

31<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

Room-based cooling: CRAC system<br />

Facts and features:<br />

+ Streamlined heat exchanger<br />

+ Operates on water, up to 118 W cooling output<br />

+ Operates on refrigerant, up to 54 W cooling output<br />

Saves time by ...<br />

• Being easy to service and to maintain<br />

$ Return on Invest (ROI):<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

CRAC system of a<br />

lea<strong>di</strong>ng competitor<br />

Usable cooling output requested: 70 kW 70 kW<br />

<strong>Rittal</strong> CRAC system<br />

3301.830<br />

Volumetric flow: 19,000 m³/h 19.500 m³/h<br />

Power consumption:<br />

(the <strong>Rittal</strong> CRAC system has a lower power<br />

consumption in partial load due to EC fan<br />

technology)<br />

5.1 kW 2.3 kW<br />

Energy consumption p.a.: 44,676 kWh/a 20,148 kWh/a<br />

Savings per year at 0.14 €/kWh:<br />

(average electricity price in 2009)<br />

3.433,92 €<br />

ROI: 2.6 years<br />

ELECTRONIC PACKAGING<br />

32<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

32<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

Suite-based cooling: LCP Inline EC<br />

Facts and features:<br />

+ Cooling output up to 30 kW<br />

+ Delivers high performance for hot spots in room-cooled<br />

data centres<br />

+ Redundancies easily achieved<br />

+ Comprehensive monitoring functions<br />

Saves time by ...<br />

• Being easy to service and to maintain<br />

$ Saves cost by ...<br />

• Using EC fan technology<br />

• Being energy-efficient due to the high water inlet<br />

temperature<br />

• Provi<strong>di</strong>ng the option of suite-based climate control<br />

without raised floor<br />

• Small footprint<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

33<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

33<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

Rack-based cooling: LCP+ EC<br />

Facts and features:<br />

+ Cooling output up to 30 kW per rack<br />

+ High availability for enclosures with high loads<br />

+ Access-protected because cooling and rack are<br />

separated<br />

+ Less than 1kW power absorption<br />

Saves time by ...<br />

• Less time required for service and maintenance<br />

$ Saves cost by ...<br />

• Using energy-efficient EC fan technology<br />

• Being energy-efficient due to the high water inlet<br />

temperature<br />

• Provi<strong>di</strong>ng the option of high-density cooling<br />

without raised floor<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

34<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

34<br />

PM-Version 1.0


Climate control<br />

Liquid Cooling Package<br />

Facts & features:<br />

+ Tailored modular climate control concepts: Baying with TS 8<br />

+ Dissipation of extremely high heat loads possible (up to 30kW)<br />

+ Highly developed software concept, inclu<strong>di</strong>ng network monitoring<br />

Time savings through ...<br />

• Simple access to all components<br />

• User-friendly maintenance and service<br />

• Touchscreen for <strong>di</strong>rect device access<br />

$ Cost savings through ...<br />

• Incorporation of EC fans<br />

• Maximisation of free-cooling contribution thanks to<br />

high water intake temperature<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

35<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

35<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

Chiller<br />

Facts and features:<br />

+ Cooling output from 15 to 462 kW<br />

+ Double cooling circuit<br />

+ High availability configuration implementing N+1<br />

redundancy (up to 8 parallel systems)<br />

+ EER greater than main competitors<br />

+ Noise reduction<br />

+ SNMP card with total control of the components and<br />

alarms (monitoring interface)<br />

Saves time by ...<br />

• Less time required for service and maintenance<br />

$ Saves cost by ...<br />

• Using free cooling kit<br />

• Using inverter pumps<br />

• Using R410A refrigerant<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

36<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

36<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

Free cooling<br />

Facts and features:<br />

+ può essere integrato nel chiller oppure esterno<br />

+ sfrutta la sola <strong>di</strong>fferenza <strong>di</strong> temperatura ΔT con<br />

l'ambiente esterno (entalpia).<br />

+ consumi energetici ridotti durante le stagioni<br />

invernali ed interme<strong>di</strong>e;<br />

+ maggiore durata dei compressori grazie ad una<br />

riduzione delle ore <strong>di</strong> funzionamento;<br />

+ minori spese <strong>di</strong> manutenzione;<br />

+ riduzione del PUE d’impianto;<br />

+ riduzione emissioni <strong>di</strong> CO 2 in ambiente;<br />

+ ROI ≤ 1 anno<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

37<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

37<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

Case history II<br />

Physical evidence<br />

2 Chiller, 15 °C inlet<br />

Cooling output (@35°C): 48kW<br />

External free cooling kit, shared<br />

Temperatures (2008) provided by Università <strong>di</strong><br />

Genova<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

Δ= - 4.727,90 €/anno<br />

(ROI ≤ 1 year)<br />

Δ= - 35,8%<br />

without fc with fc<br />

Tot 8760 KWh 110.075,10 KWh 70.675,80<br />

€ 13.209,00 € 8.481,10<br />

ELECTRONIC PACKAGING<br />

38<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

38<br />

PM-Version 1.0


Cooling<br />

Case history I<br />

Physical evidence<br />

CRAC system design, 12 °C inlet<br />

Air inlet temperature of the CRAC system 27 °C<br />

Cooling output, sensitive approx. 105 kW<br />

Room temperature 18 °C<br />

Design LCP T3+, 12 °C inlet<br />

Server inlet air 25 °C<br />

Cooling output, sensitive approx. 25 kW<br />

Flow 24 l/min<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

CRAC system design, 17 °C inlet<br />

Air inlet temperature of the CRAC system 32 °C<br />

Cooling output, sensitive approx. 105 kW<br />

Room temperature 22 °C<br />

Design LCP T3+, 17 °C inlet<br />

Server inlet air 25 °C<br />

Cooling output, sensitive approx. 25 kW<br />

Flow 40 l/min<br />

Increasing the inlet temperature does not adversely affect the data centre's climate control<br />

and cooling output.<br />

ELECTRONIC PACKAGING<br />

39<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

39<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

Case history I<br />

Free cooling periods<br />

INDUSTRIAL ENCLOSURES<br />

Inlet 12 ℃<br />

46.3 % share of free cooling<br />

Cost per year: 808.672 €<br />

Savings:<br />

Increase the share of free cooling by 24.2% while keeping cooling output at the same level<br />

Saves248,856 EUR / year for 4MW<br />

POWER DISTRIBUTION<br />

Inlet 17 °C<br />

70.5 % share of free cooling<br />

Cost per year: 559,816 €<br />

ELECTRONIC PACKAGING<br />

40<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

40<br />

PM-Version 1.0


RiZone<br />

IT <strong>System</strong>s<br />

IT Monitoring<br />

• is the data centre<br />

management software from <strong>Rittal</strong><br />

• permits the administration of<br />

the complete physical infrastructure<br />

of a data centre<br />

INDUSTRIAL ENCLOSURES<br />

MKD<br />

• Compact design, 1 U only<br />

• Various keyboard layouts<br />

• VGA input<br />

• Optional KVM switch (SSC view)<br />

for 8 or 32 servers may be integrated<br />

POWER DISTRIBUTION<br />

KVM<br />

• <strong>The</strong> right KVM solution<br />

for any KVM solution<br />

• KVM-over-IP and multi-user<br />

environments with up to 2,048 servers<br />

• May be extended at any time<br />

Dynamic Rack Control<br />

• Asset management based on RFID<br />

• Exact overview of unused<br />

U slots inside the rack<br />

• Information is saved on tags as<br />

specified by ISO standards<br />

ELECTRONIC PACKAGING<br />

41<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

41<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

Product overview <strong>–</strong> IT security<br />

CMC-TC<br />

• <strong>The</strong> <strong>Rittal</strong> sensor network:<br />

It can monitor temperatures and<br />

air humi<strong>di</strong>ty, for instance and also links with<br />

PSM or LCP for example.<br />

• Can be connected by cables or with wireless<br />

systems<br />

INDUSTRIAL ENCLOSURES<br />

Fire detection and extinguishers<br />

• Preventive solutions for<br />

data centres<br />

• <strong>System</strong>s for early fire detection<br />

and extinguishing<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

42<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

42<br />

PM-Version 1.0


IT <strong>System</strong>s<br />

RiZone - Interface<br />

UPS systems<br />

CMC<br />

Power<br />

<strong>di</strong>stribution<br />

Cooling<br />

INDUSTRIAL ENCLOSURES<br />

UPS<br />

CMC<br />

PSM<br />

Cooling /<br />

LCP<br />

POWER DISTRIBUTION<br />

BACnet<br />

Ri4Power<br />

Dynamic<br />

Rack<br />

Control<br />

Chiller<br />

ELECTRONIC PACKAGING<br />

43<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

BacNet and other<br />

GLT protocols<br />

via partners<br />

Ri4 Power<br />

Dynamic<br />

Rack Control<br />

IT chiller<br />

43<br />

PM-Version 1.0


Approccio alla progettazione<br />

L’efficienza energetica si può raggiungere<br />

Focus: garantire il maggiore<br />

risparmio energetico<br />

+ Aumento dell’efficienza <strong>degli</strong> UPS<br />

+ Riduzione del numero <strong>di</strong> cicli termici <strong>di</strong><br />

raffreddamento dei compressori<br />

+ Sfruttamento delle energie <strong>di</strong>sponibili a<br />

basso costo (acqua <strong>di</strong> falda)<br />

+ Distribuzione puntuale dell’aria fredda<br />

ottimizzandone i flussi<br />

+ setup <strong>della</strong> temperatura dell’aria fredda,<br />

secondo le <strong>di</strong>rettive 2008 <strong>della</strong> ASHRAE<br />

(18≤Taria≤27°C, 40%≤RH≤55%)<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

44<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

44<br />

PM-Version 1.0


SERVIZI A VALORE AGGIUNTO<br />

PROGETTAZIONE 3D e RENDERING<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

45<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

45<br />

PM-Version 1.0


SERVIZI A VALORE AGGIUNTO<br />

PROGETTAZIONE 3D e RENDERING<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

ELECTRONIC PACKAGING<br />

46<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

46<br />

PM-Version 1.0


Conclusioni Obiettivi raggiunti<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

Problema risolto!!!!<br />

Grazie alla virtualizzazione<br />

e ad un’infrastruttura<br />

modulare ho raggiunto gli<br />

obiettivi <strong>di</strong> risparmio<br />

energetico e posso far<br />

fronte alle nuove richieste <strong>di</strong><br />

espansione senza<br />

preoccupazioni!!!<br />

ELECTRONIC PACKAGING<br />

47<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

47<br />

PM-Version 1.0


RINGRAZIAMENTI<br />

INDUSTRIAL ENCLOSURES<br />

POWER DISTRIBUTION<br />

Le nostre referenze:<br />

RAI, TELECOM ITALIA, LAMBORGHINI, RSA, BANCA POPOLARE<br />

VICENZA,OSPEDALE VALDUCE COMO, UNIVERSITA’ BOLZANO,<br />

CASSA NAZIONALE FORENSE, EURAC, INFN, UNIVERSITA’ FEDERICO<br />

II NAPOLI, BREMBO, AUSL FORLI’, MOBY LINES, FIERA VICENZA,<br />

GRUPPO D’ARCO, SELECTA, ISTITUTO EUROPEO ONCOLOGICO<br />

MILANO, ISTITUTO SUPERIORE SANITA’, PROTEZIONE CIVILE, MOBY<br />

LINES MILANO, TEMMLER, RANDSTAD, KME FIRENZE, TECNOPOLO<br />

TIBURTINO ROMA, UNLB, KTESIOS ROMA, TELECITY REDBUS,<br />

BIOTECH SIENA, POLICLINICO MODENA, BRENNERCOM, CAREL, e<br />

molti altri<br />

www.rittal.it www.rimatrix5.com<br />

ELECTRONIC PACKAGING<br />

48<br />

SYSTEM CLIMATE CONTROL IT SYSTEMS<br />

48<br />

PM-Version 1.0