CHORUS - HOME RANGE<br />

MODULAR DEVICES - WHITE<br />

GW10306<br />

INTERLOCKED SWITCHED SOCKET-OUTLETS<br />

GW10311<br />

GW10321<br />

SHAVER SOCKET<br />

GW10331<br />

AUSTRALIAN STANDARD SOCKETS - 250V AC<br />

Code Description For No. modules Pack<br />

plug pins Chorus Carton<br />

GW 10 306 2P+E - 10A flat 2 6/48<br />

GW 10 307 2P+E - 15A flat 2 6/48<br />

INTERLOCKED SWITCHED SOCKET-OUTLETS WITH MINIATURE CIRCUIT BREAKER - 230V AC<br />

Code Description Type of Miniature Break No. modules Pack<br />

sockets circuit breakers power Chorus Carton<br />

GW 10 311 2P+E - 16A P17-P11 1P+N 16A 3 kA 2 1/2<br />

GW 10 312 2P+E - 16A P30-P17 1P+N 16A 3 kA 3 1/2<br />

CHARACTERISTICS: Interlocked switched socket-outlets with automatic miniature circuit breaker (C bend). Pits under tension only with plug inserted.<br />

APPLICATIONS: suitable for installation in the system terminations to protect the load.<br />

INTERLOCKED SWITCHED SOCKET-OUTLETS WITH RESIDUAL MINIATURE CIRCUIT BREAKER - 230V AC<br />

Code Description Type of Miniature Break Idn No. modules Pack<br />

sockets circuit breakers power Chorus Carton<br />

GW 10 321 2P+E - 16A P17-P11 1P+N 16A 3 kA 10 mA 3 1/2<br />

GW 10 322 2P+E - 16A P30-P17 1P+N 16A 3 kA 10 mA 4 1/2<br />

CHARACTERISTICS: Interlocked switched socket-outlets with automatic miniature circuit breaker (C bend) and residual current circuit breaker (type A). Pits under tension<br />

only with plug inserted.<br />

APPLICATIONS: suitable for installation in the system terminations to protect the load.<br />

EURO-AMERICAN STANDARD SHAVER SOCKET WITH INSULATION TRANSFORMER<br />

Code Power supply For Selectable output Maximum No. modules Pack<br />

voltage plug pins voltage power Chorus Carton<br />

GW 10 331 230 V AC - 50/60 Hz Ø 4 / 5 - 6,3x1,5 mm 120-230V AC 20 VA 3 1/2<br />

CHARACTERISTICS: the socket-outlet is equipped with a self-protection device against overloading.<br />

The output voltage should be selected correctly, consulting the rating of the user device before inserting the plug.<br />

The special signalling LED allows you to identify the chosen voltage.<br />

CHORUS CATALOGUE 2007 > EURODOMO > DOMOTICS > CHORUS - HOME RANGE<br />