Marilena MĂIEREAN<br />

Table 4 Determining the EERc indicator for four street lighting installations, ME 3a class<br />

R1 road surface<br />

C.1 Reflector with road lighting distribution adapted C.3 Reflector with road lighting distribution adapted<br />

to concrete<br />

to asphalted<br />

Lave=1.16 cd/m 2<br />

Uo=0.588<br />

Ul1=0.821; Ul2=0.711<br />

For a road <strong>of</strong> 500 m: 15 lighting points<br />

Installed Power=1.71 kW<br />

C.2 Reflector with road lighting distribution adapted<br />

to concrete<br />

Lave=1.04 cd/m 2<br />

Uo=0.428<br />

Ul1=0.74; Ul2=0.715<br />

For a road <strong>of</strong> 500 m: 18 lighting points<br />

Installed Power=2.05 kW<br />

R3 road surface<br />

Lave=1.52 cd/m 2<br />

Uo=0.535<br />

Ul1=0.73; Ul2=0.76<br />

For a road <strong>of</strong> 500 m: 18 lighting points<br />

Installed Power=2.05 kW<br />

C.4 Reflector with road lighting distribution adapted<br />

to asphalted<br />

Lave=1.01 cd/m 2<br />

Uo=0.427<br />

Ul1=0.825; Ul2=0.79<br />

For a road <strong>of</strong> 500 m: 17 lighting points<br />

Installed Power=1.94 kW<br />

42 Ingineria Iluminatului 2010; 12, 2: 33-44