GENERAL DESCRIPTION<br />

SDU-450XL, B/W Linear Convex scanner, employs software<br />

controlled Digital <strong>System</strong> Manager (DSM) architecture.<br />

DSM is realized by technology migration from SHIMADZU<br />

state-of-the-art diagnostic imaging modalities, such as MRI.<br />

DSM, powered by high performance RISC processor,<br />

FEATURES<br />

1. DSM controlled Multi-Dimensional Signal<br />

Enhancement<br />

DSM tunes multiple imaging parameters for<br />

beamformation, echo signal processing, image<br />

formation and temporal/spatial image processing in<br />

real time to accomplish the best enhancement of total<br />

system performance.<br />

This revolutionary central operating environment<br />

allows software to up-grade SDU-450XL to meet the<br />

future application requirements.<br />

2. Wide Aperture Imaging<br />

Utilizing wide aperture beamforming provides<br />

outstanding image uniformity and deeper penetration<br />

beyond other ultrasound scanners in its class.<br />

3. Full Spectrum Imaging Technology<br />

Full Spectrum Imaging is the result of incorporation of<br />

broad band beamformer technology and broad band<br />

probe technology.<br />

Over 10MHz imaging with extremely fine detail resolution<br />

is now achievable for compact ultrasound scanner.<br />

4. True Line image formation<br />

Real time echo pixel relocation technology enables to<br />

position each echo data at native place in the image<br />

memory and makes edge of the organ more crisp -<br />

True Line.<br />

PD579-004<br />

eliminates the need of many hardware, conventionally required<br />

and makes SDU-450XL compact, lighter and more mobile.<br />

And best of all, software controlled DSM architecture<br />

provides extreme flexibility and sets SDU-450XL as the<br />

system, open to the future.<br />

5. Unparalleled Compact Design<br />

DSM architecture allows to cut the number of<br />

conventional hardware modules by half and leads to<br />

compact design. Not like other small ultrasound<br />

scanner, specific arrangement of mechanical<br />

components provides superior capability for SDU-450XL<br />

to carry peripheral equipment.<br />

6. Digital Communication Path<br />

SDU-450XL communicates with PC and download<br />

images in original digital quality for long term storage<br />

via PC-compatible PC-card and/or cable interface.<br />

1


2<br />

CONFIGURATION<br />

STANDARD SETUP<br />

• Main unit 1<br />

• Probe hanger 1<br />

• Probe holder 1<br />

• Partition plate 2<br />

• Power cable 1<br />

• U/S jelly 1<br />

• Fuse 1<br />

• Instruction manual 1<br />

OPTIONAL PROBES<br />

SPECIFICATIONS<br />

OPTIONS<br />

• Probe selector<br />

• Video printer<br />

• Printer paper<br />

• Foot switch<br />

• ATA flash memory card<br />

• Cine memory<br />

Function;Search, replay, trimming for replay, adjustment<br />

of replay speed, *storing images, and<br />

measurement of replayed and stored images.<br />

*More than 48 x 2 frames as loop memory (in<br />

case of 256 scan lines image) can be stored.<br />

The storage capacity is upgradable from 48 x 2<br />

frames to more than 192 x 2 frames (in case of<br />

256 scan lines image).<br />

*Frame number depends on the scanning<br />

conditions and probe.<br />

Type Spec. Model Application<br />

Convex 2.5-5.0MHz/13R VA13R-035U Cardiac, Abdominal<br />

Convex 3.5-6.0MHz/13R VA13R-050U Cardiac, Abdominal<br />

Convex 2.5-5.0MHz/57R VA57R-0375U Abdominal, Obstetrics<br />

Convex 2.0-5.5MHz/57R VA57R-0375WU Abdominal, Obstetrics<br />

Linear 6.0-12.0MHz/34mm L040-100U Mammography, Superficial<br />

Linear 5.0-7.5MHz/60mm L070-075U Mammography, Superficial<br />

Trans-vaginal 4.0-8.0MHz/11R TV11R-055U Ob/Gyn<br />

Trans-rectal, bi-plane 5.0-8.0MHz/10R UB10R-065U Urology<br />

Scan method Electronic Linear/Electronic Convex<br />

Measurement Distance 4 channels<br />

Monitor 12 inch High resolution, interlace<br />

Area-Circumference 2 channels<br />

Probe Connectors 2<br />

Basic Distance, Area-Circumference, Angle,<br />

Probe Frequency 2.5 – 12MHz<br />

Volume, Time, Slope, Heart rate,<br />

Display mode B mode, M mode, B/M mode, B/B mode<br />

Histogram<br />

Sweep speed 1.25 / 2.5 / 5 / 10 sec.<br />

Obstetrics Fetal age, Fetal weight estimation,<br />

Image depth 30 – 255 mm (16 steps)<br />

Bio Physical Profile Report, Graph<br />

Pan/Zoom Write zoom/Max. 15 steps<br />

display, Twins function<br />

STC 8 steps<br />

Cardiology A.L. Method, L.V. function,<br />

Gray scale 256 levels<br />

Valve measurement, Report,<br />

Focus Transmitting; Selectable up to 4 focal zones among 16<br />

Gynecology Uterus, Ovary, Follicle ratio, Report<br />

predefined location.<br />

Urology Prostate, Bladder, Report<br />

Focal zone moves to predefined location.<br />

Others Vascular measurement function,<br />

Receiving ; 16 focal zones<br />

Hip scan, VCR Measurement<br />

Image processing Dynamic range (B, M mode) ; 32dB - 80dB<br />

Edge enhancement (B, M mode) ; 4 steps<br />

Persistence ; 6 steps<br />

Post Process<br />

Posi./Nega. inversion<br />

; 8 steps<br />

Up/Down, Left/Right inversion, Rotation 90 degree<br />

Frequency changing


CONTROL PANEL<br />

18<br />

9<br />

10<br />

13<br />

12<br />

11<br />

5<br />

31 30 29 28 27 19<br />

14<br />

15 7 2 16 8 4<br />

1 STC SWITCH Adjust the gain at a specific depth<br />

2 TRACKBALL Move the mark of measurement or<br />

probe mark/Select an item<br />

3 B GAIN VOLUME Adjust the gain signal<br />

4 SETTING DIAL Change of each parameter<br />

5 RECORD Record a displayed image by<br />

video printer<br />

6 FREEZE Freeze the image<br />

7 SET Decide the input data<br />

8 END End of operation<br />

9 MENU Select each kind of operation<br />

10 MEASURE Select each kind of measurement<br />

11 CINE Select each kind of cine function<br />

12 BODY MARK Input body mark<br />

13 ANNOTATION Input characters on the screen<br />

14 CALIPER Select caliper operation<br />

15 FOCUS Select position or combinations of<br />

focus<br />

16 M-CURSOR Display of M-mode's Cursor<br />

17<br />

3<br />

17 PAN Move the display position of<br />

image<br />

18 USER FUNCTION Select each kind of function<br />

19 ZOOM Magnification of B mode image<br />

20 HIQ High resolution mode<br />

21 SIZE Set a desired image size<br />

22 L-R FREEZE Change real mode or freeze mode<br />

of each plane in Dual B mode<br />

23 MODE Select a desired display mode<br />

24 IMAGE REVERSE Reverse the image display<br />

left/right<br />

25 IMAGE Select image adjusting function<br />

26 FREQUENCY Change of frequency<br />

27 PROBE Select Probe connector<br />

28 BIOPSY Select display of biopsy lines<br />

29 HELP Select Help function<br />

30 PRESET Select, register, or erase the preset<br />

items<br />

31 NEW PATIENT Input new patient name and<br />

information<br />

1<br />

26<br />

25<br />

20<br />

24<br />

21<br />

23<br />

22<br />

6<br />

3


DIMENSIONS AND WEIGHT Unit : mm<br />

Printed in Japan 6295-11005-30A-ADT<br />

Main body<br />

420<br />

Remarks<br />

* Every value in this Product Data Sheet is a standard value, and it may vary a little from the actual at each site.<br />

* The appearances and specifications are subject to change for reasons of improvement without notice.<br />

* Certain configurations may not be available pending regulatory clearance. Contact your Shimadzu representative for information on<br />

specific configurations.<br />

SHIMADZU CORPORATION. International Marketing Division<br />

3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101-8448, Japan Phone: 81(3)3219-5641 Fax. 81(3)3219-5710<br />

URL http://www.shimadzu.com<br />

Weight : 72kg<br />

Power supply : AC 100-120V/200-240V, ±10%<br />

450VA, 50/60Hz<br />

Operational ambient : Temp. 5-40°C<br />

temperature and<br />

humidity range<br />

Humidity 30-85%<br />

I/O interface : Video signal (OUT 3 / IN 1)<br />

Video printer remote control<br />

RS-232C<br />

Foot switch<br />

Parallel IO<br />

IC card interface (2 slots)<br />

590<br />

1220 ‘1370<br />

Shimadzu Corporation’s Medical <strong>System</strong>s Group was certified<br />

for applying a quality system for design/development,<br />

manufacturing, sales, installation and servicing of products in<br />

accordance with ISO 9001 and EN 46001.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!