R<br />

Y<br />

Y<br />

Page 2 Right Side<br />

Control Box<br />

B<br />

Heating Elements (9)<br />

P/N 20295<br />

13 14<br />

15 16<br />

17 18<br />

12<br />

11<br />

Feed End<br />

Control<br />

Settings:<br />

B = 36<br />

C = 450<br />

TLL = 1:00<br />

THH = 7:00<br />

DIR = L<br />

Multi-Product<br />

Control<br />

P/N 15161-B<br />

B<br />

Y<br />

Y<br />

B<br />

B<br />

B<br />

R<br />

Element Connection Wires 12 ga. TGGT<br />

Burner<br />

24VAC<br />

Y<br />

Y<br />

Y<br />

H. WIRING DIAGRAM - Flex Side<br />

To motor Reverse<br />

Button<br />

Heater<br />

24VDC<br />

+<br />

-<br />

Or<br />

B<br />

10<br />

3 4<br />

5 6<br />

7 8<br />

9<br />

2<br />

1<br />

B<br />

Y<br />

Y<br />

1<br />

7 6 5 4 3 2<br />

R<br />

Motor Reverse Switch<br />

P/N 13579<br />

Br<br />

W<br />

B<br />

G<br />

R<br />

W<br />

R<br />

B<br />

Circuit Breaker, 20A<br />

P/N 11965<br />

To Multi Product<br />

Control, pin 3<br />

Circuit Breaker, 3 Pole 25A<br />

P/N 19161<br />

Warmer Element<br />

P/N 20418<br />

19 20<br />

Bl<br />

Y<br />

20<br />

Broil<br />

Stabilizer Control<br />

P/N 19235<br />

19<br />

18<br />

Bl<br />

24V Relay<br />

For blower<br />

Relay P/N 18093<br />

Base P/N 18092<br />

R<br />

Y<br />

B #10<br />

B #10<br />

B<br />

B<br />

Br<br />

W<br />

R<br />

Y<br />

R<br />

B<br />

R<br />

B<br />

Or<br />

B<br />

Or<br />

W<br />

R<br />

Solid State Relay<br />

20A (3)<br />

P/N 20724<br />

A2 A1<br />

(-) (+)<br />

A2 A1<br />

(-) (+)<br />

A2 A1<br />

(-) (+)<br />

6<br />

7<br />

8<br />

9<br />

10<br />

13 14<br />

1<br />

2<br />

N<br />

L1 L2 L3<br />

T1 L1<br />

Terminal Blocks (7)<br />

P/N 18686<br />

B #12 TG G T<br />

T1 L1<br />

10<br />

Y #12 TG G T<br />

T1 L1<br />

Y<br />

Bl<br />

3<br />

Y #12 B<br />

3<br />

4<br />

11 12<br />

5<br />

Y #12 TG G T<br />

Thermocouple<br />

P/N 18861<br />

9<br />

Bl<br />

Y<br />

B #10<br />

R<br />

B<br />

B<br />

Bl<br />

Y<br />

Y #12<br />

R<br />

Or<br />

Br<br />

Y<br />

Bl #12<br />

B #10<br />

B #10<br />

B #10<br />

16<br />

15<br />

18<br />

17<br />

14<br />

13<br />

12<br />

40 <strong>Nieco</strong> Corporation - Model <strong>JF94E</strong> <strong>CE</strong><br />

24VAC from transformer<br />

24VDC from rectifier<br />

Low Voltage<br />

Conduit Motor Box<br />

Motor Cable<br />

High Voltage<br />

Conduit<br />

This document is the property of <strong>Nieco</strong><br />

Corporation. Reproduction or release without<br />

express permission is prohibited<br />

Wiring Diagram<br />

Drawn Date Model Dwg No.<br />

Rev.<br />

PB 30Jun11 JF94/84E, <strong>CE</strong>, 380-400V 20110 K<br />

Page 2 of 3<br />

To High Pressure Blower