A calibration procedure that has been carried out according to the<br />
specifications in Appendix C (section 15.2) should have no<br />
correlation among the estimated parameters. If correlation exists,<br />
the calibration procedure must be repeated while observing the<br />
guidelines.<br />
3. Variance-covariance matrices for the estimated parameters:<br />
The estimated IOP from the calibration procedure will be associated<br />
with a variance-covariance matrix. The square roots of the variances<br />
represent the standard deviations, which can be used as a measure of<br />
the quality of the estimated parameters. For a meaningful estimate of<br />
the IOP, the standard deviations must be:<br />
• Tier I < 1.0 Pixels (for the xp, yp, and c components of the<br />
IOP)<br />
• Tier II < 1.5 Pixels (for the xp, yp, and c components of the<br />
IOP)<br />
• Tier III N/A<br />
In summary, a calibration report should be provided showing the<br />
estimated parameters, estimated variance component of unit weight,<br />
standard deviations of the estimated IOP, and the correlation image.<br />
The quality of these deliverables should adhere to the provided<br />
guidelines in this section. See an example of a calibration report in<br />
Appendix D. The calibration report must be submitted in this format.<br />
5.4 Stability Analysis<br />
Estimated IOP from temporal calibration sessions must go through a<br />
stability analysis procedure to evaluate the degree of similarity<br />
between the reconstructed bundles from these sets (refer to Appendices C<br />
and D for details).<br />
The provider must furnish the estimated stability measure (RMSEoffset),<br />
which must be within the acceptable limit.<br />
• Tier I RMSEoffset < 1.0 Pixels<br />
• Tier II RMSEoffset < 1.5 Pixels<br />
• Tier III RMSEoffset : N/A<br />
Note: The above RMSEoffset values are reported by the stability analysis<br />
component of the calibration suite provided by the BC Base Mapping and<br />
Geomatic Services.<br />
5.5 Deliverable<br />
The following list of items must be provided to summarize the quality of<br />
the calibration and stability analysis procedures of the utilized<br />
Printed copy of this document is uncontrolled. For latest version see<br />
Specifications for Small and Medium Format Digital Cameras posted at _____<br />
Owner: BMGS Title: Specifications for Small and Medium Format<br />
Digital Cameras<br />
Version No: DRAFT V0.0.11 Issue Date: _______________<br />
Doc No.: __________________ ARCS/ORCS: ________________<br />
13