6.0 FILTERS:<br />
3. Variance-covariance matrices for the estimated parameters:<br />
The estimated IOP from the calibration procedure will be associated<br />
with a variance-covariance matrix. The square roots of the variances<br />
represent the standard deviations, which can be used as a measure of<br />
the quality of the estimated parameters. For a meaningful estimate of<br />
the IOP, the standard deviations must be:<br />
• Tier I < 1.0 Pixels (for the xp, yp, and c components of the<br />
IOP)<br />
• Tier II < 1.5 Pixels (for the xp, yp, and c components of the<br />
IOP)<br />
• Tier III N/A<br />
6.1 Filters:<br />
7.0 EXPOSURE:<br />
Camera and filter should be calibrated as a single operational unit.<br />
7.1 Shutter Speed:<br />
The shutter speed shall be such that it is consistent with image<br />
resolution and quality requirements.<br />
7.2 Resolution:<br />
Image motion shall be held to less than 2 pixels.<br />
Project requirements may specify full Image Motion Compensation be<br />
set.<br />
8.0 PHOTOGRAPHIC FLIGHT TOLERANCES:<br />
The following specifications must be adhered to for Tier I and Tier II<br />
photography. Tier III requirements may be specified uniquely within the<br />
contract.<br />
Printed copy of this document is uncontrolled. For latest version see<br />
Specifications for Small and Medium Format Digital Cameras posted at _____<br />
Owner: BMGS Title: Specifications for Small and Medium Format<br />
Digital Cameras<br />
Version No: DRAFT V0.0.11 Issue Date: _______________<br />
Doc No.: __________________ ARCS/ORCS: ________________<br />
15