<strong>Primary</strong> <strong>Rectifier</strong> <strong>Module</strong> PR-<strong>PFC</strong><br />

with sinusoidal mains input 3500W nom<br />

• Pluggable mains input module with<br />

sinusoidal current flow<br />

• Power factor 0,99 for minimizing total<br />

Harmonic Distortion (THD)<br />

• 385VDC nominal output voltage<br />

• 19’’ Assembly 4U for hosting up to 6<br />

units for 22kW DC output<br />

• Single Phase or 3-Phase operation<br />

• Circuit breaker with thermal<br />

protection per module, primary<br />

• 4U x450mm 14PU width plug in unit<br />

with input and output RF filter<br />

• DC output fused against short circuit<br />

Power Factor Correction <strong>Module</strong><br />

without housing<br />

This self ventilated <strong>Primary</strong> <strong>Rectifier</strong><br />

<strong>Module</strong>s have been designed to power<br />

MARATON systems over long distance<br />

primarily.<br />

Each PR-<strong>PFC</strong> is easily to withdrawal in case<br />

of any malfunction. After switch off the<br />

circuit breaker the module is immediately<br />

ready for plug out.<br />

For special request up to six PR-<strong>PFC</strong> can be<br />

operated with paralleled outputs, presumed all<br />

are connected to the same phase. The parallel<br />

operated versions are not equipped with<br />

integrated circuit breaker and need external<br />

mains switch and fuses.<br />

MN<strong>PFC</strong> 02.013<br />

1


• Technical <strong>Data</strong>: <strong>Primary</strong> <strong>Rectifier</strong><br />

Mains Input<br />

AC- Input: 100- 240VAC / 16A +/-10% (20A peak), 47-63Hz<br />

CE EN 61000, IEC 555 power fact. >0,98<br />

Inrush current: limited by soft start-circuit to 110% of nominal current (cold unit)<br />

Input protection Circuit breaker with 16/20A thermal overload protection<br />

Power Output 385 V DC +/- 15V, matched for MARATON DC/DC converter<br />

continuously 9A, 3500W nom (4,4kW peak) @ 230VAC input<br />

Regulation Load (10-90%) 1% deviation<br />

Mains (10-90%) 1% deviation<br />

Output ripple Load (10-90%) 1-10Vss 94-126Hz (double mains frequency)<br />

RF rejection:<br />

Output protection<br />

EN 55 022 Class B, Input and Output<br />

short circuit: 2 x 10A slow blow fuse, 500V type, internal situated<br />

overload: current limiting for booster circuits, 90°C cut off temperature<br />

PR- Box format: 4U x 14 TE, 450 mm deep<br />

Front panel 14 PU width acc. to VME Spec.<br />

<strong>Module</strong> connectors: 2mm pin / socket diameter.<br />

max. ratings: 25A up to 50°C, 500V. 2,2kV test voltage 50Hz<br />

PE / Ground pins outfitted as leading pin<br />

EMC Compatibility /RFI Rejection Separate Input and Output EMC Filter<br />

EMA EN 61 000-6-3:2001 [RF emission]<br />

EN 55 022:1998 + Corr:2001 + A1:2000 Class B conducted noise<br />

EN 55 022:1998+ Corr:2001 + A1:2000 Class B radiated noise<br />

EN 61 000-3-2:2001 harmonics<br />

EN 61 000-3-3:1995 +Corr:1997 +A1:2001 flicker<br />

EMB EN 61 000-6-2:2001 [immunity]<br />

EN 61 000-4-6:1996 + A1:2001 injected HF currents<br />

EN 61 000-4-3:1996 + A1:1998 + A2:2001 radiated HF fields incl. ”900MHz”<br />

EN 61 000-4-4:1995 + A1:2001 Burst<br />

EN 61 000-4-5:1995 + A1:2001 Surge<br />

EN 61 000-4-11:1994 + A1:2000 voltage variations<br />

EN 61 000-4-2:1995 + A1:1998 + A2:2001 ESD<br />

Operation temperature: 0....50°C without derating, storage: -30°C till 85°C<br />

Efficiency: better than 95 %<br />

M T B F electronics: 40°C ambient ca. 100 000 h<br />

integrated fan: 40°C ambient ca. 65 000 h, 25° ambient >85 000h<br />

Ordering Information<br />

385VDC 4.4KW<br />

1/3 phase<br />

90-265VAC /<br />

156-458VAC >20kW<br />

<strong>Primary</strong> <strong>Rectifier</strong> <strong>Module</strong> <strong>PFC</strong> (1 slot),<br />

230V 50Hz input, 385VDC output 3.5KW load 0<strong>PFC</strong>.0000<br />

<strong>Primary</strong> <strong>Rectifier</strong> Power Bin for <strong>PFC</strong>, 6<br />

slot 4U 0B07.0000<br />

2


4U <strong>Primary</strong> <strong>Rectifier</strong> Power Bin for six <strong>PFC</strong>s<br />

wiring principle<br />

In 3- phase application the two <strong>PFC</strong> outputs which are primary powered from to the same phase can be<br />

operated in parallel mode<br />

MN<strong>PFC</strong> 02.013<br />