8<br />

b. Following the appropriate wiring diagram, (refer<br />

to page 9) based on your application requirements,<br />

and using BX armored cable or Thinwall<br />

electrical metal tubing connector fittings, make<br />

electrical connections to the junction box (L).<br />

Snap Switches (Series 150S and 157S)<br />

L<br />

PUMP<br />

SWITCH<br />

PUMP<br />

CIRCUIT<br />

TERMINALS<br />

ALARM<br />

CIRCUIT<br />

TERMINALS<br />

LOW WATER<br />

CUT-OFF<br />

TERMINALS<br />

L<br />

PUMP<br />

SWITCH<br />

LOW WATER<br />

CUT-OFF AND<br />

ALARM SWITCH<br />

Automatic Reset<br />

(All models except 158S and 159S)<br />

PUMP<br />

CIRCUIT<br />

TERMINALS<br />

ALARM<br />

CIRCUIT<br />

TERMINALS<br />

L<br />

MOTORIZED<br />

VALVE<br />

SWITCH<br />

LOW WATER<br />

CUT-OFF<br />

TERMINALS<br />

MOTORIZED<br />

VALVE<br />

TERMINALS<br />

LOW WATER<br />

CUT-OFF AND<br />

ALARM SWITCH<br />

Manual Reset<br />

(All models except 158S)<br />

Mercury Switches (Series 150 and 157)<br />

L<br />

PUMP<br />

SWITCH<br />

PUMP<br />

CIRCUIT<br />

TERMINALS<br />

ALARM<br />

CIRCUIT<br />

TERMINALS<br />

LOW WATER<br />

CUT-OFF<br />

TERMINALS<br />

(All models except 158<br />

and 159)<br />

CUT-OFF<br />

AND ALARM<br />

SWITCH<br />

L<br />

ALARM<br />

CIRCUIT<br />

TERMINALS<br />

1 2 3 4 5 6<br />

LOW WATER<br />

CUT-OFF<br />

TERMINALS<br />

Automatic Reset<br />

Model 158S<br />

TO<br />

ELECTRIC<br />

VALVE<br />

L<br />

TO<br />

LOW WATER<br />

ALARM<br />

PUMP<br />

SWITCH<br />

1 2 3 4 5 6<br />

LOW WATER<br />

CUT-OFF AND<br />

ALARM SWITCH<br />

PUMP<br />

CIRCUIT<br />

TERMINALS<br />

TO<br />

LOW WATER<br />

CUT-OFF<br />

ALARM<br />

CIRCUIT<br />

TERMINALS<br />

IMPORTANT: There must be<br />

a minimum space of 1/2”<br />

(13mm) between connector<br />

fittings and electrical live<br />

metal parts.<br />

L<br />

PUMP #1<br />

SWITCH<br />

LOW WATER<br />

CUT-OFF<br />

TERMINALS<br />

Manual Reset<br />

Model 158S-M<br />

L<br />

PUMP #1<br />

CIRCUIT<br />

TERMINALS<br />

LOW WATER<br />

CUT-OFF AND<br />

ALARM SWITCH<br />

PUMP #2<br />

CIRCUIT<br />

TERMINALS<br />

Automatic Reset<br />

Model 159S<br />

NO. 1 PUMP<br />

CIRCUIT<br />

NO. 2 PUMP<br />

CIRCUIT<br />

1 2 5 6<br />

Model 158 Model 159<br />

PUMP #2<br />

SWITCH