Wiring Connections<br />

<strong>SubDrive</strong> <strong>Duplex</strong> <strong>Alternator</strong><br />

1. Verify that the power has been shut off at the main breaker.<br />

2. Open the cover to the <strong>Alternator</strong>.<br />

3. Drive Connections<br />

Connect a two-conductor pressure sensor cable from Drive 1 to the<br />

<strong>Alternator</strong>’s terminal block labeled SD1 on the right side. The red and<br />

black wire connections are interchangeable. (See Figure 2 below).<br />

Whichever Drive unit is connected to the SD1 terminal will be the primary<br />

system fi rst. The Drive unit connected to the SD2 terminal will be the<br />

backup system fi rst.<br />

A. If connecting to a <strong>SubDrive</strong>300, use the supplied two-conductor<br />

pressure sensor cable. Cut the terminals off both ends of the red<br />

and black leads from the existing four-conductor cable. Leave<br />

only the Green and White leads linking the pressure shut-off<br />

switch to its connections on the <strong>SubDrive</strong>300.<br />

B. For all other <strong>SubDrive</strong>s, cut off the quick connect ends and strip<br />

the wire to make a two-conductor cable with stripped leads at<br />

both ends.<br />

4. Repeat step 3 for Drive 2, but connect Drive 2’s pressure sensor cable to<br />

the <strong>Alternator</strong>’s terminal block labeled SD2 on the right side.<br />

Figure 2: Drive Sensor Cable Connections<br />

<strong>SubDrive</strong>300<br />

<strong>Alternator</strong><br />

1 2 1 2<br />

1 2 1 2<br />

PS-HI PS-LO SD1 SD2<br />

PRESSURE 12 VAC<br />

DRIVES<br />

ALARM SENSORS<br />

24V-1A<br />

(A)<br />

PRESSURE<br />

SENSOR SHUT-OFF<br />

To Pressure Shut-off Switch<br />

INT<br />

FAN<br />

NO<br />

RELAY<br />

PFC INV<br />

FAN FAN<br />

PRESSURE<br />

SENSOR SHUT-OFF<br />

PFC<br />

FAN<br />

INT<br />

FAN<br />

(Cut black and red wires; leave only<br />

the green and white connected to<br />

the pressure shut-off switch.)<br />

1 2 1 2<br />

1 2 1 2<br />

PS-HI PS-LO SD1 SD2<br />

PRESSURE 12 VAC<br />

DRIVES<br />

ALARM SENSORS<br />

24V-1A<br />

Note: If using a NEMA 4 <strong>SubDrive</strong>150 or <strong>SubDrive</strong>75 the quick connects or<br />

stripped leads may be used.<br />

(B)<br />

1 2<br />

<strong>SubDrive</strong><br />

10