07.08.2013 Views

REQUEST FOR INFORMATION FOR ... - Indian Army

REQUEST FOR INFORMATION FOR ... - Indian Army

REQUEST FOR INFORMATION FOR ... - Indian Army

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>REQUEST</strong> <strong>FOR</strong> IN<strong>FOR</strong>MATION <strong>FOR</strong> PROCUREMENT OF<br />

BI-MODULAR CHARGE SYSTEMS <strong>FOR</strong> 155MM GUNS<br />

1. <strong>Indian</strong> <strong>Army</strong> is planning to procure Bi-modular Charge System<br />

(BMCS) for 155mm guns. It is proposed to identify probable vendors who<br />

can undertake the above project.<br />

2. Vendors are requested to furnish comprehensive details of<br />

BMCS in form of brochures alongwith responses to the following<br />

questions:-<br />

(a) Is the propellant cased in a fully combustible Cartridge Case?<br />

(b) Do the modules have means for identification at night?<br />

(c) How can the two types of modules be differentiated from each<br />

other?<br />

(d) What is the minimum range overlap between two successive<br />

zones?<br />

(e) What is the maximum Muzzle Velocity and maximum range<br />

achieved with each zone for the following calibres :-<br />

(i) 155mm / 39 Calibre.<br />

(ii) 155mm / 45 Calibre.<br />

(iii) 155mm / 52 Calibre.<br />

(f) Dimensions. What are the dimensions of the BMCS? Can it<br />

be loaded on the loading tray/trough of existing 155mm guns without<br />

special preparation?<br />

(g) Pre Ignition. At what temperature of the barrel does pre<br />

ignition/cook off occur?<br />

(h) Operating Temperature. What is the range of operating<br />

temperature of the BMCS?


2<br />

(j) Gun Wear. What is the EFC value when a projectile is fired<br />

with the highest zone.<br />

(k) Shelf Life. What is the shelf life of the BMCS?<br />

(l) Recoil/Stroke. Is the recoil / stroke obtained in various zones<br />

within the permissible recoil limits?<br />

(m) Compatibility. Is the BMCS compatible with existing 155mm<br />

projectiles?<br />

(n) Range Tables. Can provisional Range Tables based on ICAO<br />

System be provided with the BMCS for the trials?<br />

(o) Storage. What is the temperature range under which the<br />

BMCS can be stored under field conditions?<br />

3. You are requested to forward the above details by<br />

20 Feb 2011alongwith the indicative unit cost to the address below by<br />

courier :-<br />

Integrated HQ of MoD (<strong>Army</strong>)<br />

General Staff Branch<br />

Directorate General of Artillery (Artillery-5)<br />

Room No 506A, ‘A’ Wing, Sena Bhawan<br />

New Delhi-110011<br />

Tele FAX : 011 - 2333 3609<br />

4. The information may also be sent on the following E-mail ID :-<br />

artydte_mod@nic.in