TECHNICAL (RS)-METHOPRENE
TECHNICAL (RS)-METHOPRENE
TECHNICAL (RS)-METHOPRENE
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
WHO/IS/TC/414/2001 <strong>METHOPRENE</strong><br />
<strong>TECHNICAL</strong><br />
1.3 Packing and marking of packages<br />
The technical (<strong>RS</strong>)-methoprene shall be packed in suitable clean containers as<br />
specified in the order.<br />
All packages shall bear, durably and legibly marked on the container the following:<br />
Manufacturer’s name<br />
Technical (<strong>RS</strong>)-methoprene (920 g/kg)<br />
Batch or reference number and date of test<br />
Net weight of contents<br />
Date of manufacture<br />
and the following minimum cautionary notice:<br />
(<strong>RS</strong>)-methoprene is an insect growth regulator, a juvenile hormone analogue (juvenoid)<br />
preventing insect metamorphosis to viable adults when applied to larval stages. Not known to<br />
cause adverse effect by ingestion, inhalation and contact of skin but may irritate eyes.<br />
Keep the material out of reach of children and away from foodstuffs and animal feed and their<br />
containers.<br />
First aid measures:<br />
Ingestion: Do not induce vomiting, get medical attention.<br />
Eye contact: Flush with large amounts of water.<br />
Skin contact: Wash with soap and water.<br />
2. Methods of determining chemical and physical properties<br />
2.1 Methoprene content<br />
2.1.1 Outline of method<br />
The determination of the active ingredient content in (<strong>RS</strong>)-methoprene technical is<br />
carried out by gas chromatography ( GC ), using the total area method.<br />
The constituents are separated by GC on a methyl siloxane capillary column and<br />
detected by flame ionization.<br />
2.1.2 Apparatus<br />
1. Gas-liquid chromatograph. Hewlett Packard 6890 GC with a HP 3398 GC<br />
Chemstation software or equivalent<br />
2. Chromatographic column. Capillary column 30 m long, 0.25 mm internal<br />
diameter, 0.25 µm film thickness, filled with methyl siloxane (Type: HP-1) or<br />
equivalent<br />
Before use, condition a new column by purging with nitrogen overnight at about<br />
280 °C. During this operation the column must not be connected to the detector<br />
to avoid contamination by " initial bleed " of the stationary phase.<br />
Page 2 of 9