WHO/IS/TC/414/2001 <strong>METHOPRENE</strong><br />

<strong>TECHNICAL</strong><br />

1.3 Packing and marking of packages<br />

The technical (<strong>RS</strong>)-methoprene shall be packed in suitable clean containers as<br />

specified in the order.<br />

All packages shall bear, durably and legibly marked on the container the following:<br />

Manufacturer’s name<br />

Technical (<strong>RS</strong>)-methoprene (920 g/kg)<br />

Batch or reference number and date of test<br />

Net weight of contents<br />

Date of manufacture<br />

and the following minimum cautionary notice:<br />

(<strong>RS</strong>)-methoprene is an insect growth regulator, a juvenile hormone analogue (juvenoid)<br />

preventing insect metamorphosis to viable adults when applied to larval stages. Not known to<br />

cause adverse effect by ingestion, inhalation and contact of skin but may irritate eyes.<br />

Keep the material out of reach of children and away from foodstuffs and animal feed and their<br />

containers.<br />

First aid measures:<br />

Ingestion: Do not induce vomiting, get medical attention.<br />

Eye contact: Flush with large amounts of water.<br />

Skin contact: Wash with soap and water.<br />

2. Methods of determining chemical and physical properties<br />

2.1 Methoprene content<br />

2.1.1 Outline of method<br />

The determination of the active ingredient content in (<strong>RS</strong>)-methoprene technical is<br />

carried out by gas chromatography ( GC ), using the total area method.<br />

The constituents are separated by GC on a methyl siloxane capillary column and<br />

detected by flame ionization.<br />

2.1.2 Apparatus<br />

1. Gas-liquid chromatograph. Hewlett Packard 6890 GC with a HP 3398 GC<br />

Chemstation software or equivalent<br />

2. Chromatographic column. Capillary column 30 m long, 0.25 mm internal<br />

diameter, 0.25 µm film thickness, filled with methyl siloxane (Type: HP-1) or<br />

equivalent<br />

Before use, condition a new column by purging with nitrogen overnight at about<br />

280 °C. During this operation the column must not be connected to the detector<br />

to avoid contamination by " initial bleed " of the stationary phase.<br />