Firetuf ® FIBRE Stranded loose tube cable<br />
Fire resistant stranded loose tube cable with up to 96 fibres.<br />
Inner FireRes ® sheath, corrugated steel tape armouring, outer<br />
FireRes ® sheath. VDE: U-DQHBH<br />
Application and installation<br />
Installation in tunnels and subways where there are requirements for reaction to fire<br />
Difficult installation environments where fire safety is a primary concern<br />
For conditions with risk of severe rodent attacks<br />
Standards<br />
EN 187 000, IEC 60794-3, IEC 60794-3-10, IEC 60794-3-12, ISO 11801 2 nd edition, EN 50 173-1<br />
Flame resistance<br />
LSHF-FR (FRNC): IEC 60331-25 (90)( 90 minutes at 750C); IEC 60332-1-2; IEC 60332-3-24; IEC 60332-3-22 ;<br />
IEC 60754-1; IEC 60754-2; IEC 61034; EN 50200:2000 (120 minutes at 860C, with mechanical<br />
shock (1 per 5 minutes))<br />
Options<br />
As standard this cable is provided with 12 fibres per tube, as an option other lower fibre counts are possible<br />
LINKING THE FUTURE<br />
www.prysmiangroup.com<br />
I10b_e<br />
Version 11.4 | 2012-12-28<br />
Page 1 of 3
Firetuf ® FIBRE Stranded loose tube cable<br />
Construction<br />
Central strength member Ø2.5 mm FRP rod<br />
Loose tube Ø2.3 mm jelly filled loose tubes with up to 12 fibres each<br />
Fibre colour code 1 Red 7 Brown<br />
LINKING THE FUTURE<br />
2 Green 8 Violet<br />
3 Blue 9 Turquoise<br />
4 Yellow 10 Black<br />
5 White 11 Orange<br />
6 Grey 12 Pink<br />
Water blocking The core is wrapped with swellable tape<br />
Ripcord 1<br />
Inner sheath Blue FireRes ® , EN 50290-2-27<br />
Ripcord 1<br />
(1.3 mm for 6 element construction and 0.8 mm for 8 element construction)<br />
Armouring 0.155 mm corrugated steel tape<br />
Outer sheath Blue 2.0 mm FireRes ® , EN 50290-2-27<br />
Sheath marking<br />
<strong>Draka</strong> Firetuf FIBRE I/O ST D MA LSHF-FR 1.8 kN <br />
05 U-DQHBH x /125 <br />
Physical properties<br />
Attribute IEC 60794-1-<br />
2<br />
Method<br />
Limits<br />
Fibre count - 72 96<br />
Nominal diameter [mm] - 15.5 15.5<br />
Nominal weight [kg/km] - 290 290<br />
Short term tensile strength<br />
(some days) [N]<br />
E1 1800 N<br />
Permanent tensile strength [N] E1 1200 N<br />
Crush (compressive strength)<br />
[N/100 mm]<br />
E3 3000N<br />
Impact [J] E4 20 Nm<br />
Torsion E6 30 reversed bends; R = 300 mm<br />
Kink E7 5 cycles 1 turn<br />
Fibre count E10 The cable do not form a kink when a loop is drawn together to a<br />
diameter 12 times the cable nominal diameter<br />
Minimum bending radius [mm] E11 290 290<br />
Temperature range F1 Storage: -60 ºC to 60 ºC<br />
Installation: -30 ºC to 60 ºC<br />
Operation -60 ºC to 70 ºC *)<br />
Water penetration F5B No water on free end (core only)<br />
*) In the interval -60 ºC to 70 ºC there is no attenuation variation (≤0.05 dB) for a single mode fibre, when tested<br />
according to the standard mentioned.<br />
www.prysmiangroup.com<br />
I10b_e<br />
Version 11.4 | 2012-12-28<br />
Page 2 of 3
Firetuf ® FIBRE Stranded loose tube cable<br />
Product codes – ordering information<br />
<strong>Prysmian</strong><br />
group<br />
material<br />
code<br />
[PRODUCT CODE TABLE]<br />
<strong>Prysmian</strong> Group<br />
material description<br />
LINKING THE FUTURE<br />
<strong>Draka</strong><br />
Material<br />
code<br />
www.prysmiangroup.com<br />
Fibre count Fibre type Fibre<br />
© PRYSMIAN GROUP 2011, All Rights Reserved<br />
All sizes and values without tolerances are reference values. Specifications are for product as supplied by <strong>Prysmian</strong> Group: any<br />
modification or alteration afterwards of product may give different result.<br />
The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without<br />
the written consent of <strong>Prysmian</strong> Group. The information is believed to be correct at the time of issue. <strong>Prysmian</strong> Group reserves the right to<br />
amend this specification without prior notice. This specification is not contractually valid unless specifically authorised by <strong>Prysmian</strong> Group.<br />
data<br />
sheet<br />
I10b_e<br />
Version 11.4 | 2012-12-28<br />
Page 3 of 3