EXTENDED AEBUS CONNECTIONS (<strong>AX2002</strong>)<br />

The connector for the extended AEbus is<br />

located above the AEbus connector. Only the<br />

communication is extended, not the power<br />

supply (this is achieved from the Power AEpack<br />

on which the <strong>AX2002</strong> is installed).<br />

Using 2 x 2 x 0,50 mm² shielded cable means<br />

that CH and CL must be one twisted pair.<br />

From the other pair only one cable is connected<br />

to GND. The cable shield must be connected to<br />

the housing of the AEbox.<br />

<strong>AP2003</strong> / <strong>AX2002</strong><br />

SPECIFICATIONS <strong>AP2003</strong> (Product nr. 9839720)<br />

Dimensions: 230 x 126 x 70 mm (excluding mounting rail) Weight: ± 600 gr<br />

Output: AEbus power: 27 VDC, max 1,3 A<br />

Environment: Temperature: Operating: 0 – 55 °C, Storage: -30 – 65 °C Relative humidity: 10 – 93% non condensing<br />

Power: 230 – 240 VAC (-10%+6%) 50/60 Hz, (max 0,42 Amp at 230 VAC)<br />

Safety: Class I<br />

CABLE SPECIFICATIONS<br />

230 VAC Power: 3 x 0,75mm², due to local restrictions, must have earth connection<br />

FUSES<br />

230 VAC F1 3,15A SB<br />

Resistor ON for<br />

first and last<br />

<strong>AX2002</strong><br />

<strong>AX2002</strong> first <strong>AX2002</strong> n+1 <strong>AX2002</strong> last<br />

CH<br />

CL<br />

GND<br />

Resistor OFF for<br />

all <strong>AX2002</strong>’s<br />

between<br />

AEbus extender connectors<br />

rear view<br />

It is not allowed to make a STAR connection. The extended AEbus (and also the AEbus) may only be<br />

connected in LINE.<br />

FIRMWARE<br />

Pay attention that the firmware loaded in AEpack and AEpu determines functionality and protocols.<br />

SPECIFICATIONS <strong>AX2002</strong> (Product nr. 7818386)<br />

Dimensions: Fits into Power AEpack (e.g. AP2001 / <strong>AP2003</strong>)<br />

Extended AEbus: AEbus communication, no power<br />

Environment: Temperature: Operating: 0 – 55 °C, Storage: -30 – 65 °C Relative humidity: 10 – 93% non condensing<br />

CABLE SPECIFICATIONS<br />

Extended AEbus: 2 x 2 x 0,50mm² shielded, total length extended AEbus: max 300 meter (CH and CL must be twisted)<br />

MORE INFORMATION: For more detailed information contact your local Nedap supplier or check the internet site.<br />

Resistor ON for<br />

first and last<br />

<strong>AX2002</strong><br />