A B S T R A C T<br />

RGUHS Journal <strong>of</strong> Pharmaceutical Sciences<br />

<strong>Visible</strong> <strong>Spectro</strong> <strong>Photometric</strong> <strong>Determination</strong> <strong>of</strong> <strong>Darifenacin</strong> Hydrobromide in<br />

Bulk and Pharmaceutical dosage forms<br />

Original Research Article<br />

1* 2 1 2<br />

NK Sathish , Pradeep V. Khandelwal , IA Chethan and Ashwinee Kumar Shrestha<br />

1 Dept. <strong>of</strong> Pharmaceutical Chemistry, SAC College <strong>of</strong> Pharmacy, BG Nagara - 571448, Mandya Dt., India<br />

2 Dept. <strong>of</strong> Pharmaceutical Chemistry, Bharathi College <strong>of</strong> Pharmacy, Bharathi Nagara, Mandya Dt., India<br />

A simple and sensitive visible spectro photometric method has been developed for the quantitative estimation <strong>of</strong><br />

<strong>Darifenacin</strong> hydrobromide in bulk drugs and pharmaceutical dosage forms. It involves diazotization <strong>of</strong> <strong>Darifenacin</strong><br />

hydrobromide by sodium nitrite in acidic medium followed by complexation with starch \ KI reagent to yield a bluish -<br />

purple colored complex, which shows maximum absorption at 620 nm against distilled water as blank. The results <strong>of</strong><br />

the analysis were found to be 99.67% and 98.95 % for assay with a % RSD ranging from 0.301-0.422 %. The mean %<br />

recovery for formulation first is 99.36 ± 0.491% and for that <strong>of</strong> second formulation is 99.78 ± 0.235%.<br />

Keywords: <strong>Darifenacin</strong> hydrobromide, <strong>Visible</strong> spectro photometry, Diazotization, Recovery, Assay.<br />

RGUHS Journal <strong>of</strong> Pharmaceutical Sciences<br />

Received: 29/01/2011, Modified: 21/02/2011, Accepted: 28/02/2011<br />

45<br />

Fig 1: <strong>Darifenacin</strong> Hydrobromide<br />

0<br />

NH 2<br />

N<br />

0<br />

RJPS, Apr-Jun, 2011/ Vol 1/ Issue 1


NK Sathish et al <strong>Visible</strong> <strong>Spectro</strong> <strong>Photometric</strong> <strong>Determination</strong> <strong>of</strong> <strong>Darifenacin</strong> Hydrobromide in bulk and Pharmaceutical dosage forms<br />

46<br />

RJPS, Apr-Jun, 2011/ Vol 1/ Issue 1


NK Sathish et al <strong>Visible</strong> <strong>Spectro</strong> <strong>Photometric</strong> <strong>Determination</strong> <strong>of</strong> <strong>Darifenacin</strong> Hydrobromide in bulk and Pharmaceutical dosage forms<br />

Table 1: Optical characteristics and precision data<br />

Table 2: Assay <strong>of</strong> commercial formulations.<br />

Formulation Amount Amount % Assay S.D.* % RSD*<br />

labeled found*<br />

(mg) (mg)/tab<br />

DARILONG 7.5 7.475 99.67 0.421 0.422<br />

7.5 Tablets<br />

DARILONG 15 14.842 98.95 0.298 0.301<br />

15 Tablets<br />

*Average <strong>of</strong> six determinations. S.D. is standard deviation, RSD is relative standard deviation.<br />

47<br />

Abs<br />

0.3<br />

0.2<br />

0.1<br />

0<br />

400 500 600 700 800<br />

Wavelength(nm)<br />

RJPS, Apr-Jun, 2011/ Vol 1/ Issue 1


NK Sathish et al <strong>Visible</strong> <strong>Spectro</strong> <strong>Photometric</strong> <strong>Determination</strong> <strong>of</strong> <strong>Darifenacin</strong> Hydrobromide in bulk and Pharmaceutical dosage forms<br />

48<br />

Address for Correspondence:<br />

Dr. N.K. Sathish, Pr<strong>of</strong>essor, Dept. <strong>of</strong> Pharmaceutical Chemistry, SAC College<br />

<strong>of</strong> Pharmacy, BG Nagara - 571 448, Mandya Dt., Karnataka, India.<br />

E-mail : nksathish76@rediffmail.com<br />

RJPS, Apr-Jun, 2011/ Vol 1/ Issue 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!