2<br />

Operator panels<br />

System interfaces with WinCC flexible<br />

SIMATIC 505<br />

■ Overview<br />

A variety of interfaces differing in respect of type and performance<br />

are available for linking SIMATIC HMI Panels to<br />

SIMATIC 505. However, a feature common to all is that from the<br />

point of view of the connected SIMATIC HMI Panel, the<br />

connection is always a logical point-to-point one, that is, there is<br />

always a fixed assignment between an HMI Panel and a PLC.<br />

NITP interface (not for OP 77A, TP 177A, Basic Panel,<br />

Mobile Panel 177 PN, Mobile Panel 277 IWLAN)<br />

The NITP interface runs via the PG interface of the SIMATIC 505<br />

and uses the associated CPU resources, that is, the performance<br />

capability of the SIMATIC HMI Panel is determined by the<br />

performance capability of the SIMATIC CPU used.<br />

Controller SIMATIC HMI<br />

Target hardware<br />

(PROTOCOL)<br />

(physics)<br />

SIMATIC 505 (NITP)<br />

PLC 525, 535, 565T<br />

(RS 232)<br />

PLC 545, 555<br />

(RS 232)<br />

PLC 535, 545/CPU 1101,<br />

565T (RS 422)<br />

System interface possible<br />

– System interface not possible<br />

1) Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN;<br />

Mobile Panel 177 DP, Mobile Panel 277 connection via special<br />

connecting cable and terminal box (see Mobile Panel); see manual for<br />

cable assignment.<br />

2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for<br />

Touch Panels, Operator Panels, and Multi Panels<br />

3) A standard adapter (9-/25-pin male) is required on the PLC<br />

4) A commercially available level converter (RS 232/RS 422) is required<br />

on the <strong>PC</strong><br />

5) Connection via integrated MPI/PROFIBUS interface, use the<br />

CP 5611 A2 with a standard <strong>PC</strong><br />

6) Detailed information (cable assignment) can be found in the online<br />

help for WinCC flexible and in the Communication User Manual for<br />

Windows-based systems<br />

7) Bus connector 6GK1 500-0EA02<br />

2/184<br />

OP 77A<br />

TP 177A<br />

Basic Panels<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

OP 77B<br />

TP 177B DP<br />

OP 177B DP<br />

TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel 177 DP<br />

Mobile Panel 177 PN<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

PROFIBUS DP interface (not for OP 77A, TP 177A, Basic<br />

Panel, Mobile Panel 177 PN, Mobile Panel 277 IWLAN)<br />

SIMATIC 505 PLC or SIMATIC 545, SIMATIC 555 with CP 5434<br />

With the PROFIBUS DP interface, up to 30 SIMATIC HMI Panels<br />

can be connected as SLAVES to one SIMATIC 545, 555 via a<br />

PROFIBUS network, with plug-in PROFIBUS DP/master interface<br />

type CP 5434.<br />

Communication between SIMATIC HMI Panels (DP slaves) and<br />

SIMATIC 505 (DP master) runs via PROFIBUS DP message<br />

frames in accordance with EN 50170 with higher-level<br />

"HMI profile". An application ladder which must be called for<br />

each connected SIMATIC HMI Panel is required in the PLC<br />

(example of application ladder included in ProTool scope of<br />

delivery).<br />

TP 277<br />

OP 277<br />

Mobile Panel 277<br />

Mobile Panel 277 IWLAN<br />

MP 177<br />

MP 277<br />

MP 377<br />

WinCC flexible<br />

Runtime<br />

Connection via<br />

– • 1) 2) • 1) 2) • PPX: 2601 094-<strong>80</strong>01 3)<br />

See online help 6)<br />

– • 1) 2) • 1) 2) • PPX: 2601 094-<strong>80</strong>01 3)<br />

6XV1 440-2K…<br />

(see HMI accessories/<br />

connecting cables)<br />

– • 1) • 1) • 4) See online help 6)<br />

PLC 545/CPU 1102, 555<br />

(RS 422)<br />

– • 1) • 1) • 4) See online help 6)<br />

SIMATIC 505 (PROFIBUS DP + HMI)<br />

via PROFIBUS DP to<br />

– •<br />

1 x PLC 545, 555 with<br />

CP 5434<br />

1) • 1) • 5) PROFIBUS 7)<br />

(see <strong>Catalog</strong> IK PI)