Electrodes<br />
Electrodes<br />
Type No. Description Ordering No.<br />
BlueLine 14 pH Combination electrodes BlueLine<br />
Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Ag/AgCl-reference system, temp.sensor<br />
NTC 30 kOhm, cone membrane, A-glass, 1 m fixed cable with DIN- +4-mm banana<br />
plug, length 120 mm, 12 mm Ø, -5...+100° C, 0...14 pH<br />
BlueLine 14 pH ID pH-combination electrodes with sensor recognition<br />
Electrode recognition, Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Ag/AgClreference<br />
system, temp.-sensor NTC 30 kOhm, cone membrane, A-glass, 1 m fixed cable<br />
with DIN- +4-mm banana plug, length 120 mm, 12 mm Ø, -5...+100° C, 0...14 pH<br />
BlueLine 15 pH Combination electrodes BlueLine<br />
Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Ag/AgCl-reference system, temp.sensor<br />
NTC 30 kOhm, cone membrane, A-glass, 1 m fixed cable with BNC- +4-mm banana<br />
plug, length 120 mm, 12 mm Ø, -5...+100° C, 0...14 pH<br />
BlueLine 15 pH<br />
Chinch<br />
Combination electrodes BlueLine<br />
Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Ag/AgCl-reference system, temp.sensor<br />
NTC 30 kOhm, cone membrane, A-glass, 1 m fixed cable with BNC- + Chinch plug,<br />
length 120 mm, 12 mm Ø, -5...+100° C, 0...14 pH<br />
BlueLine 15 pH ID pH-combination electrodes with sensor recognition<br />
Electrode recognition, Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Ag/AgClreference<br />
system, temp.-sensor NTC 30 kOhm, cone membrane, A-glass, 1 m fixed cable<br />
with BNC- +4-mm banana plug, length 120 mm, 12 mm Ø, -5...+100° C, 0...14 pH<br />
BlueLine 16 pH Combination electrodes BlueLine<br />
Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Ag/AgCl-reference system, cylinder<br />
membrane, L-glass, length 40/80 mm, 12/5 mm Ø, -5...+100 °C, 0...14 pH<br />
BlueLine 17 pH Combination electrodes BlueLine<br />
Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Ag/AgCl-reference system, cone<br />
membrane, A-glass, 1 m fixed cable with BNC plug, length 120 mm, 12 mm Ø,<br />
-5...+100 °C, 0...14 pH<br />
BlueLine 17 pH-R Combination electrodes BlueLine<br />
Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Ag/AgCl-reference system, cone<br />
membrane, A-glass, 1 m fixed cable with Metrohm plug, length 120 mm, 12 mm Ø,<br />
-5...+100 °C, 0...14 pH<br />
BlueLine 18 pH Combination electrodes BlueLine<br />
Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Ag/AgCl-reference system, temp.sensor<br />
Pt 1000, cone membrane, A-glass, 1 m fixed cable with DIN- +4-mm banana plug,<br />
length 120 mm, 12 mm Ø, -5...+100° C, 0...14 pH<br />
BlueLine 19 pH Combination electrodes BlueLine<br />
Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Ag/AgCl-reference system, temp.sensor<br />
Pt 1000, cone membrane, A-glass, 1 m fixed cable with BNC- +4-mm banana plug,<br />
length 120 mm, 12 mm Ø, -5...+100° C, 0...14 pH<br />
BlueLine 19 pH NN Combination electrodes BlueLine<br />
Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Ag/AgCl-ref. system, temp.sensor<br />
Pt 1000, cone membrane, A-glass, 1 m fixed cable with BNC- + 2 x 4-mm banana<br />
plug, length 120 mm, 12 mm Ø, -5...+100° C, 0...14 pH<br />
BlueLine 21 pH Combination electrodes BlueLine<br />
Glass shaft, hole-diaphragm, Referid® electrolyte, Ag/AgCl-reference system, spear membrane,<br />
L-glass, plug head, length 65/25 mm, 12/5 mm Ø, -5...+80 °C, 2...13 pH<br />
285129147<br />
285129440<br />
285129155<br />
285095730<br />
285129450<br />
285129163<br />
285129171<br />
1064746<br />
285129188<br />
285129190<br />
285129490<br />
285129217<br />
23<br />
Electrodes