Electrodes<br />
Electrodes<br />
Type No. Description Ordering No.<br />
N 64 pH-combination electrodes with plug head<br />
Glass shaft, ground joint-diaphragm, electrolyte KCl 3 mol/l, Silamid®-reference system,<br />
sphere membrane, A-glass, length 170 mm, 12 mm Ø, -5...+100 °C, 0...14 pH<br />
N 6480 Eis pH-combination electrodes with plug head<br />
Glass shaft, ground joint-diaphragm, electrolyte L 5014, Ag/AgCl-reference system, sphere<br />
membrane, A-glass, length 170 mm, 12 mm Ø, +10...+40 °C, 0...14 pH<br />
N 6480 Eth pH-combination electrodes with plug head<br />
Glass shaft, ground joint-diaphragm, electrolyte L 5034, Ag/AgCl-reference system, sphere<br />
membrane, A-glass, length 170 mm, 12 mm Ø, 0...+40 °C, 0...14 pH<br />
N 65 pH-combination electrodes with plug head<br />
Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Silamid®-reference system,<br />
sphere membrane, A-glass, tapper NS 14.5, length 103 mm 10 mm Ø, -5...+100 °C,<br />
0...14 pH<br />
N 6580 pH-combination electrodes with plug head<br />
Glass shaft, ceramic diaphragm, electrolyte KCl 3 mol/l, Silamid®-reference system,<br />
sphere membrane, A-glass, tapper NS 14.5, length 103 mm, 10 mm Ø, -5...+100 °C,<br />
0...14 pH<br />
N 6681 pH combination electrodes with screw plug head<br />
Glass shaft, ground joint diaphragm, electrolyte KCl 3 mol/l, Ag/AgCl-reference system,<br />
sphere membrane, N-glass, length 120 mm, 12 mm Ø, 0...+80 °C*, 0...14 pH<br />
N 6980 pH-combination electrodes with plug head<br />
Glass shaft, ground joint-diaphragm, electrolyte KCl 3 mol/l, Silamid®-reference system,<br />
sphere membrane, A-glass, tapper NS 14.5, length 103 mm, 10 mm Ø, -5...+100 °C,<br />
0...14 pH<br />
Na 61 Sodium combination electrode<br />
Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Silamid®-reference system,<br />
sphere membrane, Na-glass, measuring range pNa 0...6, length 170 mm, 12 mm Ø,<br />
0...+80 °C,<br />
NH 1100 Ammonia combination electrode<br />
Plastic shaft, exchangable membrane modul, measuring range 0.1 mg/l...1000 mg/l,<br />
0...+50 °C, length 120 mm, 12 mm Ø<br />
NH 1101 Ammonia combination electrode with screw plug head<br />
Plastic shaft, exchangable membrane modul, measuring range 0.1 mg/l...1000 mg/l,<br />
0...+50 °C, screw plug head, length 120 mm, 12 mm Ø<br />
OX 1100 + Oxygen electrodes<br />
Membrane covered amperometric sensor, plastic shaft, kathode platinum, anode silver,<br />
temperature sensor NTC 100 kOhm, SMEK plug head, length 120 mm, 12 mm Ø,<br />
0...+50 °C, i.e. for oxygen meter CG 867<br />
OX 1101 Oxygen electrodes with screw plug head<br />
Membrane covered amperometric sensor, plastic shaft, kathode platinum, anode silver,<br />
temperature sensor NTC 100 kW, 4-pole plug head, length 120 mm, 12 mm Ø, 0...+50 °C,<br />
i.e. for oxygen meter CG 867<br />
285100059<br />
285092337<br />
285092329<br />
285100067<br />
285102516<br />
285112352<br />
285101709<br />
285100026<br />
285102808<br />
1064386<br />
1069975<br />
285119705<br />
41<br />
Electrodes