Electrodes<br />

Electrodes<br />

Type No. Description Ordering No.<br />

N 64 pH-combination electrodes with plug head<br />

Glass shaft, ground joint-diaphragm, electrolyte KCl 3 mol/l, Silamid®-reference system,<br />

sphere membrane, A-glass, length 170 mm, 12 mm Ø, -5...+100 °C, 0...14 pH<br />

N 6480 Eis pH-combination electrodes with plug head<br />

Glass shaft, ground joint-diaphragm, electrolyte L 5014, Ag/AgCl-reference system, sphere<br />

membrane, A-glass, length 170 mm, 12 mm Ø, +10...+40 °C, 0...14 pH<br />

N 6480 Eth pH-combination electrodes with plug head<br />

Glass shaft, ground joint-diaphragm, electrolyte L 5034, Ag/AgCl-reference system, sphere<br />

membrane, A-glass, length 170 mm, 12 mm Ø, 0...+40 °C, 0...14 pH<br />

N 65 pH-combination electrodes with plug head<br />

Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Silamid®-reference system,<br />

sphere membrane, A-glass, tapper NS 14.5, length 103 mm 10 mm Ø, -5...+100 °C,<br />

0...14 pH<br />

N 6580 pH-combination electrodes with plug head<br />

Glass shaft, ceramic diaphragm, electrolyte KCl 3 mol/l, Silamid®-reference system,<br />

sphere membrane, A-glass, tapper NS 14.5, length 103 mm, 10 mm Ø, -5...+100 °C,<br />

0...14 pH<br />

N 6681 pH combination electrodes with screw plug head<br />

Glass shaft, ground joint diaphragm, electrolyte KCl 3 mol/l, Ag/AgCl-reference system,<br />

sphere membrane, N-glass, length 120 mm, 12 mm Ø, 0...+80 °C*, 0...14 pH<br />

N 6980 pH-combination electrodes with plug head<br />

Glass shaft, ground joint-diaphragm, electrolyte KCl 3 mol/l, Silamid®-reference system,<br />

sphere membrane, A-glass, tapper NS 14.5, length 103 mm, 10 mm Ø, -5...+100 °C,<br />

0...14 pH<br />

Na 61 Sodium combination electrode<br />

Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Silamid®-reference system,<br />

sphere membrane, Na-glass, measuring range pNa 0...6, length 170 mm, 12 mm Ø,<br />

0...+80 °C,<br />

NH 1100 Ammonia combination electrode<br />

Plastic shaft, exchangable membrane modul, measuring range 0.1 mg/l...1000 mg/l,<br />

0...+50 °C, length 120 mm, 12 mm Ø<br />

NH 1101 Ammonia combination electrode with screw plug head<br />

Plastic shaft, exchangable membrane modul, measuring range 0.1 mg/l...1000 mg/l,<br />

0...+50 °C, screw plug head, length 120 mm, 12 mm Ø<br />

OX 1100 + Oxygen electrodes<br />

Membrane covered amperometric sensor, plastic shaft, kathode platinum, anode silver,<br />

temperature sensor NTC 100 kOhm, SMEK plug head, length 120 mm, 12 mm Ø,<br />

0...+50 °C, i.e. for oxygen meter CG 867<br />

OX 1101 Oxygen electrodes with screw plug head<br />

Membrane covered amperometric sensor, plastic shaft, kathode platinum, anode silver,<br />

temperature sensor NTC 100 kW, 4-pole plug head, length 120 mm, 12 mm Ø, 0...+50 °C,<br />

i.e. for oxygen meter CG 867<br />

285100059<br />

285092337<br />

285092329<br />

285100067<br />

285102516<br />

285112352<br />

285101709<br />

285100026<br />

285102808<br />

1064386<br />

1069975<br />

285119705<br />

41<br />

Electrodes