SI Analytics Product List 2010 English - Clarkson Laboratory and ...
SI Analytics Product List 2010 English - Clarkson Laboratory and ...
SI Analytics Product List 2010 English - Clarkson Laboratory and ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Electrodes<br />
Electrodes<br />
Type No. Description Ordering No.<br />
BlueLine 25-5 pH Combination electrodes BlueLine<br />
Plastic shaft, fibre-diaphragm, gel electrolyte, Ag/AgCl-reference system, cylinder membrane,<br />
A glass, 5 m fixed cable with BNC plug, length 120 mm, 12 mm Ø, -5...+80 °C,<br />
0...14 pH<br />
BlueLine 26 pH Combination electrodes BlueLine<br />
Plastic shaft, fibre-diaphragm, gel electrolyte, Ag/AgCl-reference system, temp.-sensor<br />
NTC 30 kOhm, cylinder membrane, A glass, 1 m fixed cable with BNC- +4-mm banana<br />
plug, length 120 mm, 12 mm Ø, -5...+80 °C, 0...14 pH<br />
BlueLine 26 pH<br />
Chinch<br />
Combination electrodes BlueLine<br />
Plastic shaft, fibre-diaphragm, gel electrolyte, Ag/AgCl-reference system, temp.-sensor<br />
NTC 30 kOhm, cylinder membrane, A glass, 1 m fixed cable with BNC- + chinch plug,<br />
length 120 mm, 12 mm Ø, -5...+80 °C, 0...14 pH<br />
BlueLine 26-3 pH Combination electrodes BlueLine<br />
Plastic shaft, fibre-diaphragm, gel electrolyte, Ag/AgCl-reference system, temp.-sensor<br />
NTC 30 kOhm, cylinder membrane, A glass, 3 m fixed cable with BNC- +4-mm banana<br />
plug, length 120 mm, 12 mm Ø, -5...+80 °C, 0...14 pH<br />
BlueLine 27 pH Combination electrodes BlueLine<br />
Glass shaft, KPG-annular-gap-diaphragm, Referid® electrolyte, Ag/AgCl-reference system,<br />
flat membrane, L glass, length120 mm, 12 mm Ø, -5...+50 °C, 2...13 pH<br />
BlueLine 27 pH 1M-<br />
BNC-ID<br />
BlueLine 27 pH 1M-<br />
DIN-ID<br />
pH-combination electrodes with sensor recognition<br />
Glass shaft, KPG-annular-gap-diaphragm, Referid® electrolyte, Ag/AgCl-reference system,<br />
flat membrane, L glass,1 m fixed cable with BNC-plug <strong>and</strong> recognition, length120 mm,<br />
12 mm Ø, -5...+50 °C, 2...13 pH<br />
pH-combination electrodes with sensor recognition<br />
Glass shaft, KPG-annular-gap-diaphragm, Referid® electrolyte, Ag/AgCl-reference system,<br />
flat membrane, L glass,1 m fixed cable with DIN-plug <strong>and</strong> recognition, length120 mm,<br />
12 mm Ø, -5...+50 °C, 2...13 pH<br />
BlueLine 28 pH Combination electrodes BlueLine<br />
Plastic shaft, fibre-diaphragm, gel electrolyte, Ag/AgCl-reference system, temp.-sensor<br />
Pt 1000, cylinder membrane, A glass, 1 m fixed cable with DIN- +4-mm banana plug,<br />
length 120 mm, 12 mm Ø, -5...+80 °C, 0...14 pH<br />
BlueLine 28 pH -P Combination electrodes BlueLine<br />
Plastic shaft, fibre-diaphragm, gel electrolyte, Ag/AgCl-reference system, temp.-sensor<br />
Pt 1000, cylinder membrane, A glass, 1 m fixed cable with DIN- +2-mm pin plug, length<br />
120 mm, 12 mm Ø, -5...+80 °C, 0...14 pH<br />
BlueLine 28-5 pH Combination electrodes BlueLine<br />
Plastic shaft, fibre-diaphragm, gel electrolyte, Ag/AgCl-reference system, temp.-sensor<br />
Pt 1000, cylinder membrane, A glass, 5 m fixed cable with DIN- +4-mm banana plug,<br />
length 120 mm, 12 mm Ø, -5...+80 °C, 0...14 pH<br />
BlueLine 29 pH Combination electrodes BlueLine<br />
Plastic shaft, fibre-diaphragm, gel electrolyte, Ag/AgCl-reference system, temp.-sensor<br />
Pt 1000, cylinder membrane, A glass, 1 m fixed cable with BNC- +4-mm banana plug,<br />
length 120 mm, 12 mm Ø, -5...+80 °C, 0...14 pH<br />
285129540<br />
285129266<br />
285095712<br />
285129630<br />
285129274<br />
285129960<br />
285129950<br />
285129282<br />
1065896<br />
285129570<br />
1065895<br />
25<br />
Electrodes