Specifications Section 1-2<br />

Timing of special refreshing<br />

for CPU Bus Units<br />

I/O memory holding when<br />

changing operating modes<br />

ControlNet cyclic communications, remote I/O for DeviceNet Units, and other special refreshing<br />

for CPU Bus Units is performed at the following times:<br />

I/O refresh period and when the CPU BUS UNIT I/O REFRESH (DLNK(226)) instruction is<br />

executed.<br />

Supported. (Depends on the ON/OFF status of the IOM Hold Bit in the Auxiliary Area.)<br />

I/O memory, however, cannot be held for automatically allocated variables when the operating<br />

mode is changed.<br />

Load OFF function All outputs on Output Units can be turned OFF when the CPU Unit is operating in RUN,<br />

MONITOR, or PROGRAM mode.<br />

Online editing Supported, but the following restrictions apply:<br />

There restrictions in the number of times and the applicable areas for adding and deleting<br />

variables.<br />

Local variables can be added only for automatic allocation of variables.<br />

FB instances cannot be added, deleted, or changed.<br />

I/O variables (VAR_INPUT and VAR_OUTPUT) cannot be added, deleted, or changed.<br />

Global variables cannot be deleted or changed.<br />

Existing variables cannot be deleted or changed (including all properties and names).<br />

Data types cannot be added, deleted, or changed (including increasing, decreasing, and<br />

deleting members from data structures, changing array elements, etc.)<br />

FB I/O groups cannot be added, deleted, or changed.<br />

Note When a FB is edited, the entire FB definition is transferred regardless of the size of the<br />

edit.<br />

Note Power to the PLC cannot be turned OFF during backup operations.<br />

Note All building operation must be completed before online editing can be started.<br />

Timer/Counter PV refresh Binary mode only.<br />

mode<br />

Note BCD mode cannot be used.<br />

Input response time setting Time constants can be set for inputs from Basic I/O Units. The time constant can be<br />

increased to reduce the influence of noise and chattering or it can be decreased to detect<br />

shorter pulses on the inputs.<br />

Startup mode setting Supported.<br />

PROGRAM mode is the default setting.<br />

Flash memory The user program, program information, variable information, and parameter area data (e.g.,<br />

PLC Setup and setting for built-in Ethernet) are always backed up and restored automatically<br />

using flash memory.<br />

Memory<br />

Card<br />

functions<br />

Item Specifications<br />

Memory Card<br />

read/write<br />

methods<br />

Data saved in<br />

Memory Cards<br />

Data saved in<br />

Memory Cards<br />

Special instructions in user program, simple backup operation, or FTP transfers using Ethernet.<br />

Note Program replacement during operation is not supported.<br />

Data specified in user operations<br />

(Special instructions in<br />

user program or simple<br />

backup operation)<br />

For special instructions in user program:<br />

Data files (extension: .IOM, .TXT, or .CSV)<br />

User operation Simple backup operation:<br />

Program file<br />

Parameter file<br />

Data file<br />

Unit backup file<br />

Variable file<br />

Program history file<br />

Automatic saving by system Following files are automatically saved when the program is<br />

changed (downloading or online editing):<br />

Comments (variable comments, instruction comments, line<br />

comments, data structure member comments)<br />

Source code for structured text program<br />

Program history file<br />

15