COMM/DATA PROTECTION GUIDE - Tii Network Technologies
COMM/DATA PROTECTION GUIDE - Tii Network Technologies
COMM/DATA PROTECTION GUIDE - Tii Network Technologies
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>COMM</strong>/<strong>DATA</strong><br />
<strong>PROTECTION</strong> <strong>GUIDE</strong><br />
Lightning and Surge Protection for<br />
www.tiinettech.com<br />
Comm/Data <strong>Network</strong>s
TABLE OF CONTENTS...........................................................................................1-2<br />
NETWORK <strong>PROTECTION</strong> AND HAZARDS TO YOUR NETWORK..................... 3<br />
RESPONSE OF VARIOUS TRANSIENT PROTECTORS...................................... 4<br />
RE<strong>COMM</strong>ENDED <strong>PROTECTION</strong> FOR VARIOUS APPLICATIONS..................... 5<br />
PRIMARY <strong>PROTECTION</strong> MODULES..................................................................... 6-8<br />
DELTA: HIGH ENERGY, FAST RESPONSE,<br />
GAS TUBE: HIGH ENERGY, ECONOMICAL, LOW CAPACITANCE,<br />
SOLID STATE: FAST RESPONSE, LOW ENERGY LET-THROUGH,<br />
DSL MODULE: LOW CAPACITANCE, BALANCED, FAST RESPONSE,<br />
LOW VOLTAGE <strong>DATA</strong> PROTECTORS: HIGH FREQUENCY <strong>DATA</strong><br />
BUILDING ENTRANCE TERMINALS (BET)<br />
Series Overview................................................................................................... 9-10<br />
SERIES 24, 25, and 26 OVERVIEW AND COMPARISON<br />
Series 24: 66 Terminations......................................................................................11-12<br />
SPECIFICATIONS, MODEL NUMBERS, AND ORDERING INFORMATION<br />
Series 24: 110 Terminations.................................................................................... 13-14<br />
SPECIFICATIONS, MODEL NUMBERS, AND ORDERING INFORMATION<br />
Series 25: 66 & 110 Terminations............................................................................. 15<br />
SPECIFICATIONS, MODEL NUMBERS, AND ORDERING INFORMATION<br />
Series 25: Stub Input.............................................................................................. 16<br />
SPECIFICATIONS, MODEL NUMBERS, AND ORDERING INFORMATION<br />
Series 26: Stub Input & Output................................................................................ 17<br />
SPECIFICATIONS, MODEL NUMBERS, AND ORDERING INFORMATION<br />
CATEGORY 6 <strong>PROTECTION</strong> PRODUCTS<br />
606 Protector Packs............................................................................................... 18<br />
CATEGORY 5E <strong>PROTECTION</strong> PRODUCTS......................................................... 19<br />
1<br />
Table of Contents<br />
505E Protector Packs<br />
MODULAR PROTECTOR PACKS FOR HIGH-SPEED <strong>DATA</strong> AND OTHER LOW VOLTAGE APPLICATIONS<br />
1504 Protector Packs<br />
WITH LVP PROTECTOR MODULES
GENERAL APPLICATION PROTECTOR PACKS, 1-PIN STYLE.............................. 20<br />
504, 505, and 581<br />
66/110 TERMINATION <strong>PROTECTION</strong> OF TELEPHONE SYSTEMS<br />
Six Plus<br />
66/110 TERMINATIONS NETWORK <strong>PROTECTION</strong> AND AC LINE <strong>PROTECTION</strong><br />
GENERAL APPLICATION PROTECTOR PACKS, 5-PIN STYLE...............................21-22<br />
5-Pin Building Entrance Protectors<br />
SPECIFICATIONS, MODEL NUMBERS, AND ORDERING INFORMATION<br />
SECONDARY PROTECTORS................................................................................ 23<br />
Omega Protector Packs<br />
SECONDARY LINE <strong>PROTECTION</strong> FOR TELEPHONE SYSTEMS<br />
Series 575 Sneak Fuse Assembly<br />
SECONDARY LINE <strong>PROTECTION</strong><br />
578 Linebacker (PFTU)<br />
EMERGENCY TELEPHONE SERVICE DURING A POWER FAILURE<br />
DISTRIBUTION FRAME EQUIPMENT....................................................................24<br />
88 Terminal Block Family<br />
TO CONNECT EQUIPMENT ON DISTRIBUTION FRAMES<br />
P399 100-PAIR PROTECTOR BLOCK.................................................................. 25-26<br />
PROTECTOR BLOCKS FOR CONVENTIONAL CENTRAL OFFICE FRAMES WITH<br />
8 INCH CENTER LINES<br />
SERIES 28 XLBET EXTRA LARGE BUILDING ENTRANCE TERMINAL............ 27-28<br />
HIGH PAIR COUNT <strong>PROTECTION</strong> AND DISTRIBUTION ON STANDARD RELAY RACKS<br />
COMPETITOR PRODUCT REFERENCE............................................................... 29-30<br />
All Specifications Subject to Change Without Notice<br />
Table of Contents<br />
(cont'd)<br />
2
3<br />
<strong>Network</strong> Protection<br />
Sophisticated Equipment Demands Sophisticated Protection<br />
• An unprotected or insufficiently protected communications network is a hazard to both your employee’s<br />
safety and your bottom line.<br />
• When a communications line is protected by Porta Systems products, hazards are quickly and safely shorted to<br />
ground.<br />
HAZARDS TO YOUR NETWORK<br />
Lightning:<br />
By far the most common cause of electrical surge damage to the communications network<br />
is lightning. Lightning can enter your network in a number of ways. It might strike a telephone<br />
or power line, causing high voltage to enter the equipment through incoming lines,<br />
or it might strike the ground and travel along buried cables.<br />
Power Crosses:<br />
Power crosses refer to incidents where a communications line comes in physical contact<br />
with an electrical power line. This could be caused by a downed telephone pole where<br />
phone and electrical lines have crossed. These incidents cause excessive AC current conditions<br />
to be carried into the communications system.<br />
Power Faults:<br />
Power faults should not to be confused with power crosses. In most buildings, the power<br />
company’s neutral line is bonded to the telephone company’s cable. If current is introduced<br />
onto this neutral line by any means, it can be transferred to the communications line and<br />
into the equipment.<br />
Induction:<br />
Communications lines need not come in direct physical contact with lightning or power<br />
overloads for a voltage spike or surge to be introduced on a line. These hazards can<br />
be induced from nearby sources such as the magnetic field surrounding a power line.<br />
Furthermore, when a brown out occurs, the power surge that accompanies the return to<br />
normal service can be transferred to nearby communications lines.<br />
Electrostatic Discharge:<br />
Most people have experienced the effects of electrostatic discharge in the home by simply<br />
walking across a carpet, touching a metal object and receiving a small shock. Similar type<br />
of shocks can be transmitted to communications circuits through the build-up and discharge<br />
of energy in dry climates.<br />
REGISTERED TO ISO 9001:2000
Response of Various Transient Protectors<br />
Gas Discharge Tube (GDT)<br />
• A robust balanced three-electrode design.<br />
• Automatically resets after current surges of up to 10,000 Amps and high voltages.<br />
• Attractive for protecting high-speed carrier lines, such as T1, due to Ultra Low Capacitance.<br />
Solid State (S.S.)<br />
• Solid State thyristor based design.<br />
• Tighter voltage range which results in lower over-shoot voltage.<br />
• Quick transient response time.<br />
• Automatically resets after current surges of up to 100 Amps.<br />
Delta (GDT/TVS)<br />
• A robust balanced three-electrode GDT coordinated with Transient Voltage Suppressor<br />
(TVS) diodes.<br />
• Tighter voltage range which results in lower over-shoot voltage.<br />
• Quick transient response time.<br />
• Automatically resets after current surges of up to 20,000 Amps and high voltages.<br />
)<br />
V<br />
(<br />
s<br />
t<br />
l<br />
o<br />
V<br />
500<br />
400<br />
300<br />
200<br />
100<br />
Nanosecond = Billionth of a Second<br />
Actual waveshapes recorded by Tektronix TDS520 Oscilloscope<br />
Response of Overvoltage Protector<br />
230V Gas Tube (GDT)<br />
10KV/uSec (1KV pulse)<br />
230V Solid State (S.S.)<br />
230V Delta- (GDT/Solid State)<br />
Over-Shoot Voltage<br />
230V Nominal<br />
0<br />
0 100 200 300 400 500 600 700 800 900 1000<br />
Response Time<br />
Time (NanoSeconds)<br />
4
Recommended Protection of Various Applications<br />
Porta Systems Corp. is a leading provider of connection and protection products for public and private<br />
telecommunications networks. Porta Systems’ Delta, a hybrid Solid State and Gas Tube Protector Module, reacts to<br />
o ver-voltages<br />
in less than five nanoseconds and is the fastest in the industry. Over 100 patents for termination and<br />
protection products attest to Porta’s innovative engineering and support of voice and data networks.<br />
Performance Comparison Table<br />
Gas Discharge Tube<br />
(GDT)<br />
Protector Type<br />
Solid State<br />
(Thyristor)<br />
Delta<br />
(GDT/TVS)<br />
Response Time Good Best Best<br />
Voltage Precision Good Better Best<br />
Current Capability Better Good Best<br />
Low Capacitance Best Good Better<br />
Service Life Better Good Best<br />
Recommended Applications<br />
Telephony Signals<br />
Model Technology Application<br />
3B1E, 175BCXN-230 Gas Tube 230 Volt Analog (CO or Line Card), T1<br />
4B1S, 115SCN-240 Solid State 240 Volt Digital (CO lines)<br />
4B1S (75), 115SCN-75 Solid State 75 Volt Digital (Line Card)<br />
195BCDXN-230 Delta 240 Volt Digital (CO lines)<br />
195BCDXN-75 Delta 75 Volt Digital (Line Card)<br />
Data Signals - (Low Capacitance, Low Voltage)<br />
LVP18E 1, LVP6-18 2 Solid State 18 Volt Ethernet/LAN<br />
LVP27E1, LVP6-272 Solid State 27 Volt<br />
IP Cameras<br />
(12-24V applications)<br />
LVP6-652 Solid State 65 Volt Ethernet/PoE<br />
Note 1: The LVP18E and LVP27E are for Category 5E networks when used in series 505 and 1504 blocks.<br />
Note 2: The LVP6-18, LVP6-27 and LVP6-65 are for Category 6 networks when used in series 606 blocks.<br />
5
Primary Protection Modules<br />
Over 400 Models—UL Listed Protection<br />
for Every Application (7.5V to 400V)<br />
The Porta Systems family of protector modules provides<br />
primary voltage protection utilizing gas tube and solid state<br />
elements. Primary/Secondary voltage and current protection<br />
is provided by incorporating one or more of the following<br />
technologies into the protection circuit:<br />
• Gas Tubes<br />
• Thyristors<br />
• TVS Diodes<br />
• Metal Oxide Varistor (MOV)<br />
• Heat Coils<br />
• Heat Sensors<br />
• Sneak Current Fuses<br />
115SCN 115SCNHDSL 175BCXN 195BCDXN<br />
MLVP27 15SCN 75BCXN LVP27E<br />
6
Primary Protection Modules<br />
Gas Tube Protector<br />
(UL LISTED. HIGH ENERGY,<br />
ECONOMICAL, LOW CAPACITANCE)<br />
Provides a highly reliable and robust<br />
means of protecting equipment from<br />
high energy voltage and current surges<br />
(up to 10KA). The protector includes<br />
a heat-activated failsafe mechanism<br />
that provides protection against a<br />
sustained surge condition.<br />
Solid State Protector<br />
(UL LISTED. FAST RESPONSE, LOW<br />
ENERGY LET-THROUGH)<br />
With a response time of 5nanoseconds,<br />
these protectors<br />
are recommended for protection<br />
of sensitive equipment. An integral<br />
fail-safe mechanism permanently<br />
shorts the protector to ground in the<br />
presence of a sustained surge condition.<br />
Low Voltage Data<br />
Protectors<br />
(UL LISTED. HIGH-FREQUENCY <strong>DATA</strong>,<br />
ALARM, CCTV)<br />
For protection of LAN equipment<br />
and data communications circuits.<br />
Solid state technology provides fast<br />
reaction to hazardous voltage conditions<br />
and prevents damage to sensitive<br />
data equipment. For CAT 5E<br />
applications use our 505E or 1504PX2<br />
series blocks. (See page 19).<br />
7<br />
ORDERING INFORMATION:<br />
C ONFIGURATIONO VERCURRENT<br />
CROSS<br />
PROTECTOR REF. 75V 230V 400V<br />
Single-Pin NA — — 75BCXN-230 75BCXN-400<br />
Heat Coil — 95BCXN-75 95BCXN-230 95BCXN-400<br />
Five-Pin NA 3B1E — 175BCXN-230 175BCXN-400<br />
Heat Coil 4B1E 195BCXN-75 195BCXN-230 195BCXN-400<br />
ORDERING INFORMATION:<br />
C ONFIGURATIONO VERCURRENT<br />
CROSS<br />
PROTECTOR REF. 75V 240V 300V<br />
Single-Pin Heat Coil — 15SCN-75 15SCN-240 15SCN-300<br />
— 05SCN-75 05SCN-240 05SCN-300<br />
Five-Pin Heat Coil 4B1S 115SCN-75 115SCN-240 115SCN-300<br />
— 105SCN-75 105SCN-240 105SCN-300<br />
ORDERING INFORMATION:<br />
CONFIGURATION OVER CURRENT<br />
<strong>PROTECTION</strong> 7.5V 18V 27V<br />
65V<br />
Single-Pin Sneak Fuse LVP7.5E LVP18E LVP27E LVP65E
Primary Protection Modules<br />
DELTA Protector<br />
(UL LISTED. HIGH ENERGY, FAST<br />
RESPONSE)<br />
Provides cutting edge, high-speed protection<br />
for sensitive communications and<br />
data equipment particularly in high lightning<br />
areas. The DELTA TM coordinates<br />
very high speed diodes with a powerful,<br />
three-element gas tube for overvoltage<br />
protection. This provides fast response<br />
time (clamps in 5 nanoseconds) and<br />
high energy (20KA) sustainability. The<br />
DELTA TM protector also provides overcurrent<br />
protection using heat coils.<br />
xDSL Protection Modules<br />
(LOW CAPACITANCE, BALANCED,<br />
FAST RESPONSE)<br />
Provides dependable protection for<br />
the broadband communication provider.<br />
Balanced, low capacitance circuitry<br />
minimizes reflection and extends<br />
DSL frequency operating range. Solid<br />
State components minimize energy<br />
let-through.<br />
(UL LISTED. FAST RESPONSE, LOW<br />
ENERGY LET-THROUGH)<br />
Provides dependable protection<br />
for the broadband communication<br />
provider. Balanced three-electrode<br />
gas tube design and low<br />
capacitance circuitry minimizes<br />
reflection, maximizes DSL frequency<br />
operating range and distance. Ideal<br />
for POTS, ISDN, ADSL2/2+, SDSL,<br />
HDSL, RADSL, and VDSL.<br />
ORDERING INFORMATION:<br />
CONFIGURATION OVERCURRENT<br />
PROTECTOR 75V 230V 350V<br />
Single-Pin Heat Coil 95BCDXN-75 95BCDXN-230 95BCDXN-350<br />
Five-Pin Heat Coil 195BCDXN-75 195BCDXN-230 195BCDXN-350<br />
ORDERING INFORMATION:<br />
CONFIGURATION STYLE 230V<br />
Single-Pin SS/Heat Coil 15SCNHDSL-230<br />
Five-Pin SS/Heat Coil 115SCNHDS-230<br />
ORDERING INFORMATION:<br />
CONFIGURATION STYLE 330V 400V<br />
Single-Pin GDT - 75AVN-400<br />
Hybrid GDT/MOV 75HAVN-330 -<br />
Five-Pin GDT - 175AVN-400<br />
Hybrid GDT/MOV 175HAVN-330 -<br />
8
Building Entrance Terminals (BETs)<br />
In order to safeguard buildings and personnel<br />
from dangerous electrical surges, the<br />
National Electric Code (NEC) requires UL<br />
497 Primary Protection for incoming communication<br />
lines. This requirement applies<br />
to Service Providers (Telcos) at their demarcation<br />
point, and to Customer Premise owners<br />
and installers for runs between buildings in<br />
industrial, commercial, or campus environments.<br />
Failure to comply with this requirement<br />
not only creates a potentially dangerous<br />
condition, but also can result in costly fines,<br />
rework, and destruction of sensitive equipment.<br />
A Porta Systems Building Entrance<br />
Terminal (BET) equipped with its primary<br />
protectors meets or exceeds these<br />
demands.<br />
9<br />
SERIES 24 BETs<br />
Suitable for use by both Service Providers (Telcos) at<br />
their demarcation point and Customer Premise owners<br />
and installers for runs between buildings in an industrial,<br />
commercial, or campus environment.<br />
24100-66-F66P<br />
AVAILABLE WITH FACTORY INSTALLED &<br />
TESTED PROTECTORS<br />
• Choice of Single or Five Pin, Gas Tube, DELTA or<br />
Solid State Protectors. See pages 7 & 8 for protectors.<br />
PAIR COUNT<br />
• Available in 25, 50 and 100 pairs<br />
INPUT TERMINATION<br />
• Available in 66, 110, 710, MS2 and factory stubbed<br />
• Custom inputs available—contact Customer Service<br />
OUTPUT TERMINATION<br />
• Available in 66, 110, RJ 21<br />
INTERNAL FUSIBLE LINK<br />
SPLICE CHAMBER WITH COVER<br />
• Cable knock outs for top or bottom cable entry<br />
• Small swing radius— more room in tight quarters<br />
OPTIONAL LOCKABLE PROTECTOR & EQUIPMENT<br />
SIDE COVER<br />
MULTIGROUND BUS BAR<br />
• Allows approved bonding termination point<br />
LINE DESIGNATION STRIP<br />
VERTICALLY STACKABLE<br />
• Up to 400 pairs<br />
CONSTRUCTION<br />
• 18 gauge welded steel housing<br />
• Durable finish<br />
• Compact, light weight, rugged
The Most Comprehensive Line of UL Listed BETs for Primary Protection<br />
SERIES 25 BETs SERIES 26 BETs<br />
No splice chamber provides for the smallest available<br />
profile with termination blocks.<br />
25100-110-M110PC<br />
AVAILABLE WITH FACTORY INSTALLED &<br />
TESTED PROTECTORS<br />
• Choice of Five Pin Gas Tube, DELTA or<br />
Solid State Protectors. See pages 7 & 8 for protectors.<br />
PAIR COUNT<br />
• Available in 25, 50 and 100 pairs<br />
INPUT TERMINATION<br />
• Available in 66, 110, 25ft — 26 gauge stub<br />
• Custom stub lengths available–<br />
contact Customer Service<br />
OUTPUT TERMINATION<br />
• Available in 66 and 110<br />
INTERNAL FUSIBLE LINK<br />
COVER INCLUDED WITH ALL MODELS<br />
MULTIGROUND BUS BAR<br />
• Allows approved bonding termination point<br />
LINE DESIGNATION STRIP<br />
VERTICALLY STACKABLE (STUB INPUT MODELS)<br />
CONSTRUCTION<br />
• 16 gauge steel housing<br />
• Durable finish<br />
• Compact, light weight, rugged<br />
All Specifications Subject to Change Without Notice<br />
Stub in and out provides the smallest possible profile for<br />
protection, and drastically cuts punch-down labor.<br />
26100-ST-MST<br />
AVAILABLE WITH FACTORY INSTALLED & TESTED<br />
PROTECTORS<br />
• Choice of Five Pin Gas Tube, DELTA or Solid<br />
State Protectors. See pages 7 & 8 for protectors.<br />
PAIR COUNT<br />
• Available in 25, 50 and 100 pairs<br />
INPUT STUB<br />
• 25ft — 26 gauge cable stub providing fusible link<br />
OUTPUT STUB<br />
• 25ft — 24 gauge cable stub<br />
MULTIGROUND BUS BAR<br />
• Allows approved bonding termination point<br />
OFFSET INPUT AND OUTPUT STUBS<br />
• For maximum density<br />
VERTICALLY STACKABLE<br />
CONSTRUCTION<br />
• 16 gauge steel housing<br />
• Durable finish<br />
• Compact, light weight, rugged<br />
10
Series 24 Building Entrance Terminals—66 Terminations<br />
(Available with Factory Installed & Tested Gas Tube, DELTA , or Solid State Protectors. See pages 7 & 8)<br />
SPECIFICATIONS: (66 TERMINATION)<br />
Pair Count Dimensions (height x width x depth) Weight (approx.)*<br />
25 PAIR 8" x 14.5" x 4" (20.3 cm x 36.8 cm x 10.2 cm) 7 lbs.<br />
50 PAIR 8" x 14.5" x 4" (20.3 cm x 36.8 cm x 10.2 cm) 9 lbs.<br />
100 PAIR 12" x 16.5" x 4" (30.5 cm x 41.9 cm x 10.2 cm) 12 lbs.<br />
* Weight - Add approx 0.5 oz per installed module.<br />
BET MODEL NUMBER DESIGNATION KEY<br />
24/25/26 = BET SERIES M = FIVE PIN<br />
110 or 66 = TERMINATION F = SINGLE PIN<br />
25/50/100 = PAIR COUNT RJ = RJ21 RECEPTACLE<br />
ST = 25 FT. CABLE STUBBED<br />
P = FACTORY INSTALLED PROTECTORS<br />
C = COVER<br />
11<br />
66 TERMINATION<br />
24100-66-M66P<br />
100 PAIR ORDERING INFORMATION<br />
MODEL NUMBER PAIR TERM PIN PROTECTORS COVER<br />
COUNT INPUT OUTPUT CONFIGURATION INSTALLED<br />
24100-66-F66 100 66 66 SINGLE NO NO<br />
24100-66-F66C 100 66 66 SINGLE NO YES<br />
24100-66-F66P 100 66 66 SINGLE YES NO<br />
24100-66-F66PC 100 66 66 SINGLE YES YES<br />
24100-66-FRJ 100 66 RJ SINGLE NO NO<br />
24100-66-FRJC 100 66 RJ SINGLE NO YES<br />
24100-66-FRJP 100 66 RJ SINGLE YES NO<br />
24100-66-FRJPC 100 66 RJ SINGLE YES YES<br />
24100-66-M66 100 66 66 FIVE NO NO<br />
24100-66-M66C 100 66 66 FIVE NO YES<br />
24100-66-M66P 100 66 66 FIVE YES NO<br />
24100-66-M66PC 100 66 66 FIVE YES YES<br />
24100-66-MRJ 100 66 RJ FIVE NO NO<br />
24100-66-MRJC 100 66 RJ FIVE NO YES<br />
24100-66-MRJP 100 66 RJ FIVE YES NO<br />
24100-66-MRJPC 100 66 RJ FIVE YES YES
CUSTOMIZED CONFIGURATIONS AVAILABLE (MS 2 OR 710 TERMINATIONS).<br />
CONTACT CUSTOMER SERVICE AT: 1-800-937-6782.<br />
50 PAIR ORDERING INFORMATION<br />
MODEL NUMBER PAIR TERM PIN PROTECTORS COVER<br />
COUNT INPUT OUTPUT CONFIGURATION INSTALLED<br />
24050-66-F66 50 66 66 SINGLE NO NO<br />
24050-66-F66C 50 66 66 SINGLE NO YES<br />
24050-66-F66P 50 66 66 SINGLE YES NO<br />
24050-66-F66PC 50 66 66 SINGLE YES YES<br />
24050-66-FRJ 50 66 RJ SINGLE NO NO<br />
24050-66-FRJC 50 66 RJ SINGLE NO YES<br />
24050-66-FRJP 50 66 RJ SINGLE YES NO<br />
24050-66-FRJPC 50 66 RJ SINGLE YES YES<br />
24050-66-M66 50 66 66 FIVE NO NO<br />
24050-66-M66C 50 66 66 FIVE NO YES<br />
24050-66-M66P 50 66 66 FIVE YES NO<br />
24050-66-M66PC 50 66 66 FIVE YES YES<br />
24050-66-MRJ 50 66 RJ FIVE NO NO<br />
24050-66-MRJC 50 66 RJ FIVE NO YES<br />
24050-66-MRJP 50 66 RJ FIVE YES NO<br />
24050-66-MRJPC 50 66 RJ FIVE YES YES<br />
All Specifications Subject to Change Without Notice<br />
66 TERMINATION<br />
24100-66-F66P<br />
25 PAIR ORDERING INFORMATION<br />
MODEL NUMBER PAIR TERM PIN PROTECTORS COVER<br />
COUNT INPUT OUTPUT CONFIGURATION INSTALLED<br />
24025-66-F66 25 66 66 SINGLE NO NO<br />
24025-66-F66C 25 66 66 SINGLE NO YES<br />
24025-66-F66P 25 66 66 SINGLE YES NO<br />
24025-66-F66PC 25 66 66 SINGLE YES YES<br />
24025-66-FRJ 25 66 RJ SINGLE NO NO<br />
24025-66-FRJC 25 66 RJ SINGLE NO YES<br />
24025-66-FRJP 25 66 RJ SINGLE YES NO<br />
24025-66-FRJPC 25 66 RJ SINGLE YES YES<br />
24025-66-M66 25 66 66 FIVE NO NO<br />
24025-66-M66C 25 66 66 FIVE NO YES<br />
24025-66-M66P 25 66 66 FIVE YES NO<br />
24025-66-M66PC 25 66 66 FIVE YES YES<br />
24025-66-MRJ 25 66 RJ FIVE NO NO<br />
24025-66-MRJC 25 66 RJ FIVE NO YES<br />
24025-66-MRJP 25 66 RJ FIVE YES NO<br />
24025-66-MRJPC 25 66 RJ FIVE YES YES<br />
12
Series 24 Building Entrance Terminals—110 Terminations<br />
(Available with Factory Installed & Tested Gas Tube, DELTA, or Solid State Protectors. See pages 7 & 8)<br />
100 PAIR ORDERING INFORMATION<br />
MODEL NUMBER PAIR TERMI PIN PROTECTORS COVER<br />
COUNT INPUT OUTPUT CONFIGURATION INSTALLED<br />
24100-110-F110 100 110 110 SINGLE NO NO<br />
24100-110-F110C 100 110 110 SINGLE NO YES<br />
24100-110-F110P 100 110 110 SINGLE YES NO<br />
24100-110-F110PC 100 110 110 SINGLE YES YES<br />
24100-110-FRJ 100 110 RJ SINGLE NO NO<br />
24100-110-FRJC 100 110 RJ SINGLE NO YES<br />
24100-110-FRJP 100 110 RJ SINGLE YES NO<br />
24100-110-FRJPC 100 110 RJ SINGLE YES YES<br />
24100-110-M110 100 110 110 FIVE NO NO<br />
24100-110-M110C 100 110 110 FIVE NO YES<br />
24100-110-M110P 100 110 110 FIVE YES NO<br />
24100-110-M110PC 100 110 110 FIVE YES YES<br />
24100-110-MRJ 100 110 RJ FIVE NO NO<br />
24100-110-MRJC 100 110 RJ FIVE NO YES<br />
24100-110-MRJP 100 110 RJ FIVE YES NO<br />
24100-110-MRJPC 100 110 RJ FIVE YES YES<br />
13<br />
110 TERMINATION<br />
24100-110-M110C<br />
SPECIFICATIONS (1-PIN): (110 TERMINATION)<br />
Pair Count Dimensions (height x width x depth) Weight (approx.)*<br />
25 PAIR 8" x 14.5" x 4" (20.3 cm x 36.8 cm x 10.2 cm) 7 lbs.<br />
50 PAIR 12" x 16.5" x 4" (30.5 cm x 41.9 cm x 10.2 cm) 12 lbs.<br />
100 PAIR 12" x 16.5" x 4" (30.5 cm x 41.9 cm x 10.2. cm) 12 lbs.<br />
SPECIFICATIONS (5-PIN): (110 TERMINATION)<br />
Pair Count Dimensions (height x width x depth) Weight (approx.)*<br />
25 PAIR 6.75" x 14.5" x 6" (17.1 cm x 37 cm x 15.5 cm) 13 lbs.<br />
50 PAIR 6.75" x 14.5" x 6" (17.1 cm x 37 cm x 15.5 cm) 15 lbs.<br />
100 PAIR 10.75" x 14.5" x 6" (27.3 cm x 37 cm x 15.5 cm) 16 lbs.<br />
* Weight - Add approx 0.5 oz per installed module.<br />
BET MODEL NUMBER DESIGNATION KEY<br />
24/25/26 = BET SERIES M = FIVE PIN<br />
110 or 66 = TERMINATION F = SINGLE PIN<br />
25/50/100 = PAIR COUNT RJ = RJ21 RECEPTACLE<br />
ST = 25 FT. CABLE STUBBED<br />
P = FACTORY INSTALLED PROTECTORS<br />
C = COVER
CUSTOMIZED CONFIGURATIONS AVAILABLE (MS 2 OR 710 TERMINATIONS).<br />
CONTACT CUSTOMER SERVICE AT: 1-800-937-6782.<br />
50 PAIR ORDERING INFORMATION<br />
MODEL NUMBER PAIR TERM PIN PROTECTORS COVER<br />
COUNT INPUT OUTPUT CONFIGURATION INSTALLED<br />
24050-110-F110 50 110 110 SINGLE NO NO<br />
24050-110-F110C 50 110 110 SINGLE NO YES<br />
24050-110-F110P 50 110 110 SINGLE YES NO<br />
24050-110-F110PC 50 110 110 SINGLE YES YES<br />
24050-110-FRJ 50 110 RJ SINGLE NO NO<br />
24050-110-FRJC 50 110 RJ SINGLE NO YES<br />
24050-110-FRJP 50 110 RJ SINGLE YES NO<br />
24050-110-FRJPC 50 110 RJ SINGLE YES YES<br />
24050-110-M110 50 110 110 FIVE NO NO<br />
24050-110-M110C 50 110 110 FIVE NO YES<br />
24050-110-M110P 50 110 110 FIVE YES NO<br />
24050-110-M110PC 50 110 110 FIVE YES YES<br />
24050-110-MRJ 50 110 RJ FIVE NO NO<br />
24050-110-MRJC 50 110 RJ FIVE NO YES<br />
24050-110-MRJP 50 110 RJ FIVE YES NO<br />
24050-110-MRJPC 50 110 RJ FIVE YES YES<br />
All Specifications Subject to Change Without Notice<br />
110 TERMINATION<br />
24100-110-F110PC<br />
25 PAIR ORDERING INFORMATION<br />
MODEL NUMBER PAIR TERM PIN PROTECTORS COVER<br />
COUNT INPUT OUTPUT CONFIGURATION INSTALLED<br />
24025-110-F110 25 110 110 SINGLE NO NO<br />
24025-110-F110C 25 110 110 SINGLE NO YES<br />
24025-110-F110P 25 110 110 SINGLE YES NO<br />
24025-110-F110PC 25 110 110 SINGLE YES YES<br />
24025-110-FRJ 25 110 RJ SINGLE NO NO<br />
24025-110-FRJC 25 110 RJ SINGLE NO YES<br />
24025-110-FRJP 25 110 RJ SINGLE YES NO<br />
24025-110-FRJPC 25 110 RJ SINGLE YES YES<br />
24025-110-M110 25 110 110 FIVE NO NO<br />
24025-110-M110C 25 110 110 FIVE NO YES<br />
24025-110-M110P 25 110 110 FIVE YES NO<br />
24025-110-M110PC 25 110 110 FIVE YES YES<br />
24025-110-MRJ 25 110 RJ FIVE NO NO<br />
24025-110-MRJC 25 110 RJ FIVE NO YES<br />
24025-110-MRJP 25 110 RJ FIVE YES NO<br />
24025-110-MRJPC 25 110 RJ FIVE YES YES<br />
14
Series 25 Building Entrance Terminals<br />
(Available with Factory Installed & Tested Gas Tube, DELTA, or Solid State Protectors. See pages 7 & 8)<br />
25100-66-M66C<br />
SPECIFICATIONS: (66 & 110 TERMINATION)<br />
Pair Count Dimensions (height x width x depth) Weight (approx.)<br />
25 PAIR 8" x 9.75" x 4.6" (20.3 cm x 24.8 cm x 11.7 cm) 7 lbs.<br />
50 PAIR 11" x 9.75" x 4.6" (27.9 cm x 24.8 cm x 11.7 cm) 9 lbs.<br />
100 PAIR 13.5" x 13.5" x 4.6" (34.3 cm x 34.3 cm x 11.7 cm) 12 lbs.<br />
* Weight - Add approx 0.5 oz per installed module.<br />
15<br />
66 & 110 TERMINATION<br />
25050-110-M110C (COVER NOT SHOWN)<br />
25025-66-M66C (COVER NOT SHOWN)<br />
66 & 110 ORDERING INFORMATION<br />
MODEL NUMBER PAIR TERM PIN PROTECTORS COVER<br />
COUNT INPUT OUTPUT CONFIGURATION INSTALLED<br />
25100-110-M110C 100 110 110 FIVE NO YES<br />
25100-110-M110PC 100 110 110 FIVE YES YES<br />
25100-66-M66C 100 66 66 FIVE NO YES<br />
25100-66-M66PC 100 66 66 FIVE YES YES<br />
25050-110-M110C 50 110 110 FIVE NO YES<br />
25050-110-M110PC 50 110 110 FIVE YES YES<br />
25050-66-M66C 50 66 66 FIVE NO YES<br />
25050-66-M66PC 50 66 66 FIVE YES YES<br />
25025-110-M110C 25 110 110 FIVE NO YES<br />
25025-110-M110PC 25 110 110 FIVE YES YES<br />
25025-66-M66C 25 66 66 FIVE NO YES<br />
25025-66-M66PC 25 66 66 FIVE YES YES
STANDARD STUB LENGTH — 25 FT. FOR CUSTOMIZED STUB LENGTHS CONTACT:<br />
CUSTOMER SERVICE AT: (800) 937-6782.<br />
25100-ST-M66C<br />
SPECIFICATIONS: (STUB INPUT)<br />
Pair Count Dimensions (height x width x depth) Weight (approx.)*<br />
25 PAIR 8" x 9.75" x 6.56" (20.3 cm x 24.8 cm x 166.7 cm) 17 lbs.<br />
50 PAIR 8" x 9.75" x 6.56" (20.3 cm x 24.8 cm x 16.7 cm) 21 lbs.<br />
100 PAIR 10.75" x 12.5" x 6.56" (27.3 cm x 31.8 cm x 16.7 cm) 27 lbs.<br />
* Weight - Add approx 0.5 oz per installed module.<br />
All Specifications Subject to Change Without Notice<br />
STUB INPUT (26 GAUGE)<br />
25100-ST-M110C (COVER & MODULES NOT SHOWN)<br />
STUBBED ORDERING INFORMATION<br />
MODEL NUMBER PAIR TERM PIN PROTECTORS COVER<br />
COUNT INPUT OUTPUT CONFIGURATION INSTALLED<br />
25100-ST-M110C 100 ST 110 FIVE NO YES<br />
25100-ST-M110PC 100 ST 110 FIVE YES YES<br />
25100-ST-M66C 100 ST 66 FIVE NO YES<br />
25100-ST-M66PC 100 ST 66 FIVE YES YES<br />
25050-ST-M110C 50 ST 110 FIVE NO YES<br />
25050-ST-M110PC 50 ST 110 FIVE YES YES<br />
25050-ST-M66C 50 ST 66 FIVE NO YES<br />
25050-ST-M66PC 50 ST 66 FIVE YES YES<br />
25025-ST-M110C 25 ST 110 FIVE NO YES<br />
25025-ST-M110PC 25 ST 110 FIVE YES YES<br />
25025-ST-M66C 25 ST 66 FIVE NO YES<br />
25025-ST-M66PC 25 ST 66 FIVE YES YES<br />
BET MODEL NUMBER DESIGNATION KEY<br />
24/25/26 = BET SERIES M = FIVE PIN<br />
110 or 66 = TERMINATION F = SINGLE PIN<br />
25/50/100 = PAIR COUNT RJ = RJ21 RECEPTACLE<br />
ST = 25 FT. CABLE STUBBED<br />
P = FACTORY INSTALLED PROTECTORS<br />
C = COVER<br />
16
Series 26 Building Entrance Terminals<br />
(Available with Factory Installed & Tested Gas Tube, DELTA, or Solid State Protectors. See pages 7 & 8)<br />
STUB INPUT (26 GAUGE CABLE) & STUB OUTPUT (24 GAUGE CABLE)<br />
BET MODEL NUMBER DESIGNATION KEY<br />
24/25/26 = BET SERIES M = FIVE PIN<br />
110 or 66 = TERMINATION F = SINGLE PIN<br />
25/50/100 = PAIR COUNT RJ = RJ21 RECEPTACLE<br />
ST = 25 FT. CABLE STUBBED<br />
P = FACTORY INSTALLED PROTECTORS<br />
C = COVER<br />
17<br />
26025-ST-MST<br />
26050-ST-MST<br />
SPECIFICATIONS: (STUB INPUT & OUTPUT)<br />
Pair Count Dimensions (height x width x depth) Weight (approx.)*<br />
25 PAIR 8" x 4" x 3.72" (20.3 cm x 10.16 cm x 9.5 cm) 7 lbs.<br />
50 PAIR 13" x 4" x 3.72" (33.1 cm x 10.16 cm x 9.5 cm) 9 lbs.<br />
100 PAIR 23" x 4" x 3.72" (61.0 cm x 10.16 cm x 9.5 cm) 12 lbs.<br />
* Weight - Add approx 0.5 oz per installed module.<br />
STUBBED ORDERING INFORMATION<br />
26100-ST-MST<br />
MODEL NUMBER PAIR TERM PIN PROTECTORS COVER<br />
COUNT INPUT OUTPUT CONFIGURATION INSTALLED<br />
26100-ST-MST 100 ST ST FIVE NO NO<br />
26100-ST-MSTP 100 ST ST FIVE YES NO<br />
26050-ST-MST 50 ST ST FIVE NO NO<br />
26050-ST-MSTP 50 ST ST FIVE YES NO<br />
26025-ST-MST 25 ST ST FIVE NO NO<br />
26025-ST-MSTP 25 ST ST FIVE YES NO
C A T E G O R Y 6 P R O T E C T I O N P R O D U C T S<br />
606 Protector Packs<br />
FOR <strong>PROTECTION</strong> OF <strong>DATA</strong> NETWORK EQUIPMENT, WORKSTATIONS, ROUTERS, SWITCHES,<br />
• Building Entrance Protection that maintains<br />
CAT 6 performance<br />
• UL 497, UL 497A, & UL 497B Listed for<br />
Primary, Secondary, and Isolated Loop<br />
Circuit Protection<br />
• Ultra low capacitance solid state technology<br />
provides protection transparent to<br />
frequencies up to 250 MHz<br />
• Factory loaded with 18V, 27V or 65V Solid<br />
State modules<br />
• Ideal for Power Over Ethernet (PoE) circuit<br />
protection using the 65 volt module<br />
• 110 Termination<br />
• Cover included<br />
606-27 W/O<br />
COVER<br />
DIMENSIONS:<br />
H x W x D (Approx.)<br />
4.75” x 2.88” x 3.38” (12.1 cm x 7.3 cm x 8.6 cm)<br />
(with cover)<br />
All Specifications Subject to Change Without Notice<br />
ORDERING INFORMATION: 606 PROTECTOR PACKS<br />
PAIRS TERM. 18V 27V 65V<br />
4 110 606-18 606-27 606-65<br />
REPLACEMENT MODULES<br />
LVP6-18 LVP6-27 LVP6-65<br />
18
C A T E G O R Y 5 E P R O T E C T I O N P R O D U C T S<br />
505E Protector Packs<br />
FOR <strong>PROTECTION</strong> OF <strong>DATA</strong> NETWORK EQUIPMENT—ROUTERS, SWITCHES, HUBS.<br />
• Ultra low capacitance Solid State technology<br />
provides protection transparent to frequencies up<br />
to 100 MHz for CAT 5E performance<br />
• UL 497, UL 497A, and UL 497B Listed for Primary,<br />
Secondary, and Isolated Loop Circuit Protection.<br />
• Mounts directly on DIN rail or may be mounted on<br />
industry standard 89 style standoff bracket for wire<br />
management<br />
• Style 89 Standoff brackets included with 12, 24 and 32 pair<br />
• DIN rail mounting bracket included with 4 and 8 pair<br />
• 110 Termination<br />
• Covers included<br />
• Designed for use in an enclosure<br />
• Available factory loaded with 7.5V, 18V, 27V or 65V<br />
Solid State modules.<br />
• 4 pair modular design allows for easy custom<br />
configuration<br />
DIMENSIONS:<br />
Pair Count H x W x D (Approx.)<br />
4 PAIR 1.3” x 3.9” x 3.5”<br />
w/o DIN rail (3.3 cm x 9.9 cm x 8.9 cm)<br />
4 PAIR 4.4" x 3.9" x 3.5"<br />
w/DIN rail (11.2 cm x 9.9 cm x 8.9 cm)<br />
8 PAIR 4.4" x 3.9" x 3.5"<br />
w/DIN rail (11.2 cm x 9.9 cm x 8.9 cm)<br />
12 PAIR 5.0" x 3.9" x 4.9"<br />
w/89E Bracket (12.7 cm x 9.9 cm x 12.5 cm)<br />
24 & 32 PAIR 10.5" x 3.9" x 4.9"<br />
w/89D Bracket (26.7 cm x 9.9 cm x 12.5 cm)<br />
1504 Protector Packs<br />
19<br />
1504PX28LVP27E<br />
505E32-27<br />
505E12-27<br />
(COVERS NOT SHOWN)<br />
ORDERING INFORMATION: 505E PROTECTOR PACKS<br />
PAIRS TERM. MOUNTING 7.5V 18V 27V 65V<br />
4 110 DIN rail 505E4-7.5 505E4-18 505E4-27 505E4-65<br />
8 110 DIN rail 505E8-7.5 505E8-18 505E8-27 505E8-65<br />
12 110 89E Standoff<br />
Bracket<br />
505E12-7.5 505E12-18 505E12-27 505E12-65<br />
24 110 89D Standoff<br />
Bracket<br />
505E24-7.5 505E24-18 505E24-27 505E24-65<br />
32 110 89D Standoff<br />
Bracket<br />
505E32-7.5 505E32-18 505E32-27 505E32-65<br />
ORDERING INFORMATION: 1504 CAT 5E PROTECTOR PACKS<br />
NO OF TERM. 7.5V 18V 27V 65V<br />
PROTECTORS<br />
4 110 1504PX24LVP7.5E 1504PX24LVP18E 1504PX24LVP27E 1504PX24LVP65E<br />
8 110 1504PX28LVP7.5E 1504PX28LVP18E 1504PX28LVP27E 1504PX28LVP65E<br />
WITH AC <strong>PROTECTION</strong><br />
NO OF TERM.<br />
PROTECTORS<br />
7.5V 18V 27V 65V<br />
4 110 1504PXACLVP7.5E 1504PXACLVP18E 1504PXACLVP27E 1504PXACLVP65E
General Application Protector Packs, 1-Pin Style<br />
General Application 504, 505, and 581 Protector Packs<br />
FOR TERMINATION AND <strong>PROTECTION</strong> OF DIGITAL AND ANALOG TELEPHONE SYSTEMS.<br />
• The units can be cascaded to accommodate immediate system<br />
requirements as well as future growth.<br />
• Protector Packs feature a sturdy, flame-retardant housing and are factory<br />
loaded with 6, 10, 12, or 25 gas tube, DELTA, or solid state protectors.<br />
ORDERING INFORMATION: 504 PROTECTOR PACKS<br />
NUMBER TERM.<br />
OF<br />
PROTECTORS<br />
BLOCK<br />
ONLY<br />
GAS TUBE<br />
230V<br />
FACTORY INSTALLED PROTECTORS<br />
DELTA DELTA DELTA<br />
75V 230V 350V<br />
SOLID STATE<br />
240V<br />
6 66 504PX2 504PX26GT 504PX26D75 504PX26D 504PX26D350 504PX26SS<br />
10 66 504PX210GT 504PX210D75 504PX210D 504PX210D350 504PX210SS<br />
6 110 1504PX2 1504PX26GT 1504PX26D75 1504PX26D 1504PX26D350 1504PX26SS<br />
10 110 1504PX210GT 1504PX210D75 1504PX210D 1504PX210D350 1504PX210SS<br />
ORDERING INFORMATION: 505 PROTECTOR PACKS<br />
FACTORY INSTALLED PROTECTORS<br />
NUMBER TERM.<br />
OF BLOCK GAS TUBE DELTA DELTA DELTA SOLID STATE<br />
PROTECTORS ONLY 230V 75V 230V 350V 240V<br />
6 110 505P8 505P6GT 505P6D75 505P6D 505P6D350 505P6SS<br />
12 110 505P12 505P12GT 505P12D75 505P12D 505P12D350 505P12SS<br />
ORDERING INFORMATION: 581 PROTECTOR PACKS<br />
NUMBER TERM.<br />
OF<br />
PROTECTORS<br />
BLOCK<br />
ONLY<br />
GAS TUBE<br />
230V<br />
FACTORY INSTALLED PROTECTORS<br />
DELTA DELTA<br />
75V 230V<br />
DELTA<br />
350V<br />
SOLID STATE<br />
240V<br />
25 66 581P2 581P225GT 581P225D75 581P225D 581P225D350 581P225SS<br />
25 110 1581P2 1581P225GT 1581P225D75 1581P225D 1581P225D350 1581P225SS<br />
Six-Plus—General Application with AC Line Protection<br />
FOR TERMINATION AND <strong>PROTECTION</strong> OF <strong>COMM</strong>UNICATIONS EQUIPMENT, CABLED TO EXTERNAL TELEPHONE LINES AND AC POWER<br />
SOURCES, INCLUDING PBXS, KSUS, FAX MACHINES, MODEMS AND COMPUTERS.<br />
• Six-line capacity device providing AC and line protection in a single unit.<br />
• Protects against, surges, sneak currents and electrostatic discharge,<br />
while providing EMI/RFI noise reduction and isolation on the AC circuit.<br />
• Common grounding point eliminates ground potential difference that<br />
exists when AC and telephone lines are protected separately. Simply plug<br />
in your PBX (
G E N E R A L A P P L I C A T I O N P R O T E C T O R P A C K S , 5 - P I N<br />
5-Pin Building Entrance Protectors<br />
FOR <strong>PROTECTION</strong> OF DIGITAL AND ANALOG TELEPHONE SYSTEMS.<br />
• UL 497 Listed for Primary Protection.<br />
• Utilizes industry standard 5-Pin protector modules.<br />
• Compact, lightweight design.<br />
• 66 or 110 IDC termination input and output.<br />
Model 506 & 1506 - 6 Pair Building Entrance Protector<br />
ORDERING INFORMATION:<br />
Model 512 & 1512 - 12 Pair Building Entrance Protector<br />
• High-impact, fire-retardant housing.<br />
• Units can be cascaded to provide for expansion<br />
• Can be mounted to 89 style stand-off brackets.<br />
(Model 525 and 1525 only)<br />
PAIRS TERM. BLOCK 230V GAS TUBE 240V SOLID STATE 230V DELTA 75V DELTA<br />
ONLY PROTECTORS PROTECTORS PROTECTORS PROTECTORS<br />
6 66 506 506GT 506SS 506D 506D75<br />
6 110 1506 1506GT 1506SS 1506D 1506D75<br />
DIMENSIONS:<br />
Model # Dimensions (height x width x depth)<br />
506 4" x 4.6" x 3.3" (10 cm x 11.7 cm x 8.2 cm)<br />
1506 3.75" x 4" x 3.3" (9.5 cm x 10 cm x 8.2 cm)<br />
ORDERING INFORMATION:<br />
PAIRS TERM. BLOCK<br />
ONLY<br />
230V GAS TUBE<br />
PROTECTORS<br />
240V SOLID STATE<br />
PROTECTORS<br />
230V DELTA<br />
PROTECTORS<br />
75V DELTA<br />
PROTECTORS<br />
12 66 512 512GT 512SS 512D 512D75<br />
12 110 1512 1512GT 1512SS 1512D 1512D75<br />
DIMENSIONS:<br />
Model # Dimensions (height x width x depth)<br />
512 5.6" x 3.75" x 3.3" (14.2 cm x 9.5 cm x 8.2 cm)<br />
1512 3.75" x 5.6" x 3.3" (9.5 cm x 14.2 cm x 8.2 cm)<br />
21<br />
1506<br />
1512<br />
506<br />
512
G E N E R A L A P P L I C A T I O N P R O T E C T O R P A C K S , 5 - P I N<br />
5-Pin Building Entrance Protectors (cont'd)<br />
Model 525 & 1525 - 25 Pair Building Entrance Protector<br />
ORDERING INFORMATION:<br />
PAIRS TERM. BLOCK 230V GAS TUBE 240V SOLID STATE 230V DELTA 75V DELTA<br />
ONLY PROTECTORS PROTECTORS PROTECTORS PROTECTORS<br />
25 66 525 525GT 525SS 525D 525D75<br />
25 110 1525 1525GT 1525SS 1525D 1525D75<br />
DIMENSIONS:<br />
Model # Dimensions (height x width x depth)<br />
525 & 1525 10" x 3.4" x 3.5" (25.4 cm x 11.7 cm x 8.2 cm)<br />
All Specifications Subject to Change Without Notice<br />
525<br />
1525<br />
22
OMEGA PROTECTOR BLOCKS<br />
1581P225M240<br />
Series 575 Sneak Fuse Assembly<br />
23<br />
575-4UL<br />
SECONDARY <strong>PROTECTION</strong> PRODUCTS<br />
• Dependable Secondary Protection to stop surges<br />
that make it past the Primary protector<br />
• An added level of protection after the primary protector,<br />
when the primary protection may not be sufficient<br />
• UL 497 and UL 497A Listed for Primary and<br />
Secondary Protection<br />
• UL 497B Listed for Isolated Loop Circuit Protection<br />
• Solid State devices for overvoltage protection<br />
• Fuse elements for overcurrent protection<br />
575-5UL<br />
• Dependable sneak current protection for up to 25 lines.<br />
• Protects against fire causing current overloads in walls and floors.<br />
• Protects personnel, property, electronic equipment.<br />
• Sturdy, UL 94-V0 fire retardant housing<br />
• UL 497A Listed—Secondary protection<br />
ORDERING INFORMATION: 575 SNEAK FUSE ASSEMBLY<br />
CABLE SIDE EQUIPMENT SIDE<br />
MODEL TERMINATION TERMINATION<br />
575-1UL 66 RJ21 Female<br />
575-2UL 66 66 with <strong>Network</strong> Disconnect RJ21<br />
575-3UL 66 RJ21 Male<br />
575-4UL RJ21 Male RJ21 Female<br />
575-5UL 66 66<br />
25AUL SNEAK FUSE REPLACEMENT PROTECTOR<br />
POWER FAIL TRANSFER UNIT<br />
578 Linebacker<br />
ORDERING INFORMATION: 578 LINEBACKE<br />
ORDERING INFORMATION:<br />
OMEGA PROTECTOR BLOCKS<br />
DC Breakdown Pair<br />
Model<br />
66 240 25 581P225M240<br />
110 240 12 505P12M240<br />
110 240 25 1581P225M240<br />
REPLACEMENT MODULES<br />
240V 15SCSN-240<br />
PROVIDES EMERGENCY TELEPHONE SERVICE IN THE EVENT OF A POWER OUTAGE<br />
OR<br />
• Automatically activates, connecting eight pre-assigned “critical use”<br />
phone lines directly to Central Office trunks.<br />
• Automatically returns circuits to PBX/KSU when power is restored.<br />
• A practical alternative to Uninterruptible Power Supplies.<br />
• Installs in less than 10 minutes.<br />
• Compatible with digital key systems.<br />
• Can be cascaded to increase the number of critical use phone lines.<br />
MODEL DESCRIPTION<br />
578PFTU 8 circuit equipped with both 66 and RJ21 termination can be wired for<br />
either automatic loop-start or ground-start capability
D I S T R I B U T I O N F R A M E E Q U I P M E N T<br />
Model 88 Terminal Block Family - Front Facing General Purpose, High Density<br />
88 EQUIPMENT TERMINAL BLOCKS ARE USED TO TERMINATE THE EXCHANGE EQUIPMENT PAIRS ON THE HORIZONTAL SIDE OF A<br />
CONVENTIONAL MAIN DISTRIBUTION FRAME (MDF), AND PROVIDE THE CROSS-CONNECT FIELD FOR JUMPERING TO THE OUTSIDE PLANT<br />
(OSP) VERTICAL SIDE OF THE FRAME FOR <strong>PROTECTION</strong> OF TELEPHONE SYSTEMS.<br />
• 8" block accommodates most conventional<br />
horizontal frame mounting configurations<br />
• Bifurcated wire wrap pins for the cross-connect<br />
field are available as "88B"<br />
• Hinged connection field facilitates easy termination<br />
of equipment pairs<br />
• Ample designation areas on both front and back of<br />
cover<br />
Model 88 Terminal Block<br />
ORDERING INFORMATION:<br />
Model Pair Count Input Output<br />
88/96 96 Wire Wrap Wire Wrap<br />
88/100 100 Wire Wrap Wire Wrap<br />
88/128 128 Wire Wrap Wire Wrap<br />
88/150 150 Wire Wrap Wire Wrap<br />
88/192 192 Wire Wrap Wire Wrap<br />
88/200 200 Wire Wrap Wire Wrap<br />
88/256 256 Wire Wrap Wire Wrap<br />
88B/96 96 Bifurcated Wire Wrap Wire Wrap<br />
88B/100 100 Bifurcated Wire Wrap Wire Wrap<br />
88B/128 128 Bifurcated Wire Wrap Wire Wrap<br />
DIMENSIONS:<br />
Pair Count Dimensions (height x width x depth) Weight<br />
96-256 4.1" x 7.04" x 3.5" (10.4 cm x 17.9 cm x 8.9 cm) 3.3 lbs<br />
Model 88/C Terminal Block<br />
ORDERING INFORMATION:<br />
• 8 mounting holes allow mounting on most any<br />
conventional frame<br />
• Wire Wrap terminations for equipment (input) and<br />
cross- connect (output) as per Telcordia specifications<br />
• RJ21 inputs on "C" models (88/96C, etc)<br />
• Face of the block is set at an angle to allow easy<br />
termination with wire wrap gun<br />
• Designation label included<br />
Model Pair Count Input Output<br />
88/96C 96 32-Pair RJ21 (Female) Wire Wrap<br />
88/100C 100 25-Pair RJ21 (Female) Wire Wrap<br />
88/128C 128 32-Pair RJ21 (Female) Wire Wrap<br />
88/150C 150 25-Pair RJ21 (Female) Wire Wrap<br />
88/192C 192 32-Pair RJ21 (Female) Wire Wrap<br />
88/200C 200 25-Pair RJ21 (Female) Wire Wrap<br />
88/256C* 256 32-Pair RJ21 (Female) Wire Wrap<br />
88B/96C 96 32-Pair RJ21 (Female) Bifurcated Wire Wrap<br />
88B/100C 100 25-Pair RJ21 (Female) Bifurcated Wire Wrap<br />
88B/128C 96 32-Pair RJ21 (Female) Bifurcated Wire Wrap<br />
*This special 256-pair version is the highest density available in the market. It is also CAT5 compliant<br />
for superior transmission of DSL signals and other high frequency circuits.<br />
DIMENSIONS:<br />
Pair Count Dimensions (height x width x depth) Weight<br />
96-256 7.94" x 3.5" x 8.16" (20.2 cm x 8.9 cm x 20.7 cm) 3.8 lbs<br />
All Specifications Subject to Change Without Notice<br />
88 TERMINAL BLOCK<br />
88/C TERMINAL BLOCK<br />
88/256C<br />
24
P399 100-Pair Protector Block<br />
C E N T R A L O F F I C E P R O T E C T O R B L O C K<br />
PROTECTS PERSONNEL AND VALUABLE EQUIPMENT FROM DAMAGING ELECTRICAL SURGES THAT MAY GET ONTO INCOMING CABLE<br />
LINES. MOUNTS ON CONVENTIONAL CENTRAL OFFICE FRAMES WITH 8 INCH CENTER LINES.<br />
ORDERING INFORMATION: P399<br />
FEATURES:<br />
• 100-pair front facing test field<br />
• Compact design saves space and increases<br />
number of protected pairs per frame vertical<br />
• Accepts industry standard 5-pin protector<br />
modules<br />
• Gold plated protector module sockets and test<br />
field contacts offer superior electrical contact,<br />
minimizing noise problems<br />
• Front ground test point offers labor savings and<br />
reliability<br />
• Fanning strips allow easy wire management for<br />
both field stubbing and cross connection to<br />
horizontal blocks bracket<br />
• Cross connect field available with Wire Wrap<br />
(WW) or bifurcated Quick Clip (QC)<br />
• Custom swivel stub<br />
• Operating Temperature: -13˚F to 149˚F<br />
(-25˚C to 65˚C)<br />
MODEL# Termination Factory Stubbed Cable<br />
P399-WW Wire-Wrap No None<br />
P399-WW-24x25 Wire-Wrap Yes 25 feet of 24 AWG<br />
P399-WW-24x50 Wire-Wrap Yes 50 feet of 24 AWG<br />
P399-WW-24x75 Wire-Wrap Yes 75 feet of 24 AWG<br />
P399-WW-24x100 Wire-Wrap Yes 100 feet of 24 AWG<br />
P399-WW-22x25 Wire-Wrap Yes 25 feet of 22 AWG<br />
P399-WW-22x50 Wire-Wrap Yes 50 feet of 22 AWG<br />
P399-WW-22x75 Wire-Wrap Yes 75 feet of 22 AWG<br />
P399-WW-22x100 Wire-Wrap Yes 100 feet of 22 AWG<br />
P399-QC Quick-Clip No None<br />
P399-QC-24x25 Quick-Clip Yes 25 feet of 24 AWG<br />
P399-QC-24x50 Quick-Clip Yes 50 feet of 24 AWG<br />
P399-QC-24x75 Quick-Clip Yes 75 feet of 24 AWG<br />
P399-QC-24x100 Quick-Clip Yes 100 feet of 24 AWG<br />
P399-QC-22x25 Quick-Clip Yes 25 feet of 22 AWG<br />
P399-QC-22x50 Quick-Clip Yes 50 feet of 22 AWG<br />
P399-QC-22x75 Quick-Clip Yes 75 feet of 22 AWG<br />
P399-QC-22x100 Quick-Clip Yes 100 feet of 22 AWG<br />
25
P399 100-Protector Block (cont'd)<br />
C E N T R A L O F F I C E P R O T E C T O R B L O C K<br />
THE P399 IS A COMPACT 100-PAIR CONNECTOR THAT UTILIZES INDUSTRY STANDARD 5-PIN PROTECTOR MOD-<br />
7.5"<br />
DIMENSIONS:<br />
H x W x D (Approx.)<br />
8.5” x 4.5” x 7.5” (21.6 cm x 11.4 cm x 19.1 cm)<br />
All Specifications Subject to Change Without Notice<br />
8.5"<br />
4.5." MAX<br />
8.5"<br />
26
HIGH PAIR COUNT <strong>PROTECTION</strong> & DISTRIBUTION<br />
Series 28 XLBET - Distribution Frame<br />
ORDERING INFORMATION: SERIES 28 XLBET<br />
MODEL# PAIRS INPUT OUTPUT<br />
28300-ST-MRJF 300 Three 100 pair 26' guage 25 ft. Cables 12 Cables w/Female RJ tails<br />
28300-ST-M110U* 300 Three 100 pair 26' guage 25 ft. Cables 300-pair 110 connection block<br />
12RJ110MU* 300 12 Cables w/Male RJ tails 300-pair 110 connection block<br />
24RJ110MU* 600 24 Cables w/Male RJ tails Two 300-pair 110 connection blocks<br />
12RJ110F 300 12 Cables w/Female RJ tails 300-pair 110 connection block<br />
UWMB110 N/A Mounting Bracket for two 300 pair 110 connection blocks with wire guides<br />
RJEQ 600 RJ21 Connector Plate<br />
*Any model numbers ending in the letter "U", includes UWMB110<br />
27<br />
Back Front<br />
FEATURES:<br />
• UL listed for Primary Protection.<br />
• Can be installed on industry standard 23" x 6" deep<br />
relay rack.<br />
• 1800-pair with cross connect field can be mounted<br />
on a 7 ft. rack.<br />
• 2400-pair without the cross connect field mounts<br />
on 7 ft. rack.<br />
• Includes all mounting hardware and wire<br />
management guides.<br />
• External, front mounted grounding lugs allows for<br />
"daisy chaining" the units together on frame.<br />
• Separate cross connect field (110 or other) can be<br />
mounted on the output side of the rack.<br />
• Compatible with all industry standard 5-pin style<br />
protector modules.<br />
.<br />
THE SERIES 28 EXTRA LARGE BET (XLBET) IS A HIGH-DENSITY RACK MOUNTED PROTECTED SOLUTION. THE XLBET MOUNTS ON A<br />
STANDARD 23" RACK PROVIDING <strong>PROTECTION</strong> FOR 1800 PAIRS WITH CROSS CONNECT FIELDS OR 2400 PAIRS WITHOUT CROSS CON-<br />
NECT FIELDS. RJ21 CONNECTORS ALLOW FOR EASY CABLING TO TELEPHONY EQUIPMENT. THE FRONT SIDE OF THE RACK PROVIDES<br />
CROSS CONNECTION BETWEEN THE XLBETS AND EQUIPMENT CABLING.<br />
THE XLBET UTILIZES INDUSTRY STANDARD 5-PIN PROTECTOR MODULES.
8.56"<br />
8.56<br />
4.69<br />
HIGH PAIR COUNT <strong>PROTECTION</strong> & DISTRIBUTION<br />
Series 28 XLBET - Mechanical Specifications for each 300 Pair BET<br />
• Construction-16 gauge steel, durable finish<br />
• Input Stubbing- Three, 100-Pair, 25 foot, 26 AWG riser/plenum rated cables provides integrated fusible link<br />
• Output-110 Terminal Blocks (connected to BET via RJ21 connectors)<br />
• Twelve 25 pair 24 AWG output cables connectorized with female RJ21 connectors<br />
• 25-Pair RJ21 connectorized output stubs connect easily with cross connect blocks<br />
• Output stubs can be made to custom cable lengths for direct equipment cabling<br />
• Custom stub lengths available<br />
• 5 U Space on 23” Rack per 300-Pairs. Up to 2400 pair on one rack (1800 with cross connects)<br />
• Large ground lug for easy connection of all units with facilities ground points<br />
4.69"<br />
Porta Systems offers a wide range of Main Distribution<br />
Frame products. For ordering, installation, and<br />
engineering information please contact a Technical<br />
Support Manager at: 1-800-937-6782.<br />
24"<br />
24.00<br />
Front View<br />
All Specifications Subject to Change Without Notice<br />
PAIRS 201-300 PAIRS 101-200 PAIRS 1-100<br />
251-275<br />
276-300<br />
201-225<br />
151-175<br />
226-250 176-200<br />
101-125<br />
126-150<br />
Back View<br />
Top View Side View<br />
51-75<br />
76-100<br />
1-25<br />
26-50<br />
28
29<br />
Building<br />
Entrance<br />
Protectors<br />
Protector<br />
Modules<br />
505E<br />
Protector<br />
Packs<br />
606<br />
Protector<br />
Packs<br />
COMPETITOR PRODUCT REFERENCE<br />
Porta Systems<br />
Solution<br />
CommScope<br />
(Systimax)<br />
Functional Equivalents for<br />
Circa<br />
Emerson<br />
(Marconi)<br />
506 - 2606QC/QC -<br />
506GT - 2606QC/QC (w/3B1E) -<br />
1506 110ANA1-06 1880110/US-6 -<br />
1506GT 1880110/US-6 (w/3B1E)<br />
512 - 2612QC/QC -<br />
512GT - 2612QC/QC (w/3B1E) -<br />
1512 - - -<br />
1512GT - - -<br />
525 - 2625QC/QC R66P25<br />
525GT - 2625QC/QC (w/3B1E) R66P25<br />
(w/3B1E)<br />
1525 110ANA1-25 - -<br />
1525GT 110ANA1-25 (w/3B1E) - -<br />
75BCXN-230 3B1E (Single Pin) 3B1E (Single Pin) 3B1E (Single Pin)<br />
95BCXN-230 4B1E (Single Pin) 4B1E (Single Pin) 4B1E (Single Pin)<br />
15SCN-240 4B1S (Single Pin) 4B1S (Single Pin) 4B1S (Single Pin)<br />
175BCXN-230 3B1F C3B1E R3B1E<br />
175BCXN-400 3B1EW C3B1E R3B1E<br />
195BCXN-230 4B1F C4B1E R4B1E<br />
195BCXN-400 4B1EW C4B1E R4B1E<br />
105SCN-75 - C3B1S-75 -<br />
105SCN-240 3B1FS C3B1FS R3B1FS<br />
105SCN-300 3B1S C3B1S R3B1S<br />
115SCN-75 4B1FS-75 C4B1S-75 (PTC) -<br />
115SCN-240 4B1FS C4B1FS (PTC) R4B1FS<br />
115SCN-300 4B1S C4B1S (PTC) R4B1S<br />
115SCNHDSL-230 4C1FS C3B1FS-BAL -<br />
MLVP27 - C3B1S-30 -<br />
505E4-18<br />
505E8-18<br />
505E12-18<br />
505E32-18<br />
Cross with<br />
Systimax 108224774<br />
Cross with ITW Linx and<br />
Panamax LAN5E<br />
protectors<br />
-<br />
-<br />
-<br />
-<br />
606-18 760028373 Cross with ITW Linx<br />
-<br />
606-27 760033951 and Panamax<br />
-<br />
606-65 190A1-100 LAN6 Protectors<br />
-
Pair<br />
Count<br />
100<br />
50<br />
25<br />
COMPETITOR PRODUCT REFERENCE<br />
Porta Systems<br />
Building Entrance Terminal<br />
(BET) Solution<br />
CommScope<br />
(Systimax)<br />
Functional Equivalents for<br />
Circa<br />
Emerson<br />
(Marconi)<br />
26100-ST-MST 190A1-100 1900A1-100 -<br />
25100-110-M110C - 1880ENA1/NSC-100G BEPNCT100T<br />
25100-66-M66C - 1890ECT1/NSC-100 BEPNCC100C<br />
25100-ST-M110C 489ACC1-100 1880B1-100 BEPT100SC25<br />
25100-ST-M66C 489BCC1-100 1890BC1-100 BEPC100SC25<br />
26100-ST-MST 190A1-100 1900A1-100 R13410012<br />
24100-110-M110C 489ACA1-100 1880ECA1-100G BEPT100T<br />
24100-66-M66C 489BCB1-100 1890ECT1-100 BEPC100C<br />
25050-110-M110C - 1880ENA/NSC-50G BEPNCT50T<br />
25050-66-M66C - 1890ECT1/NSC-50 BEPNCC50C<br />
25050-ST-M110C 489ACC1-050 1880B1-50 BEPT50SC25<br />
25050-ST-M66C 489BCC1-050 1890BC1-50 BEPC50SC25<br />
26050-ST-MST 190A1-50 - R134506<br />
24050-110-M110C 489ACA1-050 1880ECA1-50G BEPT50T<br />
24050-66-M66C 489BCB1-050 1180ECT1-50 BEPC50C<br />
25025-110-M110C - 1880ENA1/NSC-25G BEPNCT25T<br />
25025-66-M66C - 1890ECT/NSC-25 BEPNCC25C<br />
25025-ST-M110C 489ACC1-025 1880B1-25 BEPT25SC25<br />
25025-ST-M66C 489BCC1-025 1890BC1-25 BEPC25SC25<br />
26025-ST-MST - - -<br />
24025-110-M110C 489ACA1-025 1880ECA1-25G BEPT25T<br />
24025-66-M66C 489BCB1-025 1880ECT1-25 BEPC25C<br />
1. Add a "P" before the "C" of any BET part number to have the BET factory loaded with 230-volt Gas tube protectors<br />
(3B1E equivalents). For Example: 24100-110-M110PC.<br />
2. Add a "PCS" at the end of any BET part number to have the BET factory loaded with Solid State protectors (4B1S<br />
equivalents). For Example: 24100-110-M110PCS.<br />
3. Custom BET configurations and specialty products such as 710 and MS 2 inputs and CAT 5E and CAT 6 entrance<br />
protectors are available. Contact Porta Systems customer service or your local manufacturer's representative<br />
for assistance.<br />
All Specifications Subject to Change Without Notice<br />