<strong>StarServe</strong> IR<br />
Expander<br />
<strong>8000IREX</strong><br />
<strong>Installation</strong> <strong>Instructions</strong>
<strong>8000IREX</strong> <strong>StarServe</strong> IR Expander <strong>Installation</strong> <strong>Instructions</strong><br />
1.0 Description<br />
The <strong>Clipsal</strong> <strong>8000IREX</strong> is used to expand the IR system of the <strong>Clipsal</strong><br />
8073/8VHPIR Video Distribution Unit (VDU). It provides up to 64 outputs with IR<br />
control (8 VDUs using the outputs from the master VDU). The <strong>8000IREX</strong> passes IR<br />
signals from the expansion VDUs to the master VDU. All broadband and modulated<br />
signals brought to the main panel are available at the expansion VDU outputs with<br />
minimal signal loss.<br />
2.0 Important Notes<br />
• Each expansion VDU must be powered by its own separate power supply.<br />
• Modulators connected to the expansion VDUs will only be viewable on outputs<br />
from that expansion VDU.<br />
• Bidirectional (12V) IR signals are not bidirectional to other expansion VDUs.<br />
Bidirectional IR signals will only function within the original expansion VDU and<br />
master VDU outputs<br />
3.0 <strong>Installation</strong><br />
To install the IR Expander:<br />
1) Connect the <strong>8000IREX</strong> between an output of the master VDU and an<br />
input of the expansion VDU. Ensure to connect the expansion VDU to the<br />
system side of the <strong>8000IREX</strong>.<br />
2) Connect the IR cable to the <strong>8000IREX</strong> and plug the input jack into to the IR<br />
socket on the Expansion Hub.<br />
3) Plug the 12V d.c. supply into the <strong>8000IREX</strong> and switch on.<br />
Refer to the installation diagram in Figure 1.<br />
© <strong>Clipsal</strong> Australia Pty Ltd
<strong>8000IREX</strong> <strong>StarServe</strong> IR Expander <strong>Installation</strong> <strong>Instructions</strong><br />
8050P12/1600<br />
Power<br />
12VDC<br />
B<br />
pwr<br />
© <strong>Clipsal</strong> Australia Pty Ltd<br />
IR<br />
Power<br />
12VDC<br />
B<br />
pwr<br />
IR<br />
Video Distribution Unit<br />
(3 input × 8 output) w/IR Engine<br />
1 2 3 4<br />
dulators tv output<br />
5 6 7 8<br />
Master Hub<br />
Video Distribution Unit (3 input × 8 output) w/IR Engine<br />
dulators tv output CATV<br />
/ANT<br />
7<br />
SYSTEM<br />
1 2 3 4<br />
57 6 7 87<br />
<strong>8000IREX</strong><br />
CATV<br />
/ANT<br />
7<br />
Power<br />
12VDC<br />
B<br />
pwr<br />
7<br />
SYSTEM<br />
TV 7<br />
TV 7<br />
Figure 1 - Typical installation<br />
IR<br />
Antenna<br />
Connect to any<br />
output port<br />
Video Distribution Unit<br />
(3 input × 8 output) w/IR Engine<br />
1 2 3 4<br />
dulators tv output CATV<br />
/ANT<br />
7<br />
5 6 7 8<br />
8050P12/1600
© Copyright <strong>Clipsal</strong> Integrated Systems Pty Ltd 2<strong>01</strong>1. All rights reserved. This material<br />
is copyright under Australian and international laws. Except as permitted under the<br />
relevant law, no part of this work may be reproduced by any process without prior written<br />
permission of and acknowledgement to <strong>Clipsal</strong> Integrated Systems Pty Ltd.<br />
<strong>Clipsal</strong> and <strong>StarServe</strong> are registered trademarks of <strong>Clipsal</strong> Australia Pty Ltd.<br />
The information in this manual is provided in good faith. Whilst <strong>Clipsal</strong> Integrated Systems<br />
(CIS) has endeavoured to ensure the relevance and accuracy of the information, it<br />
assumes no responsibility for any loss incurred as a result of its use. CIS does not<br />
warrant that the information is fit for any particular purpose, nor does it endorse its use in<br />
applications which are critical to the health or life of any human being. CIS reserves the<br />
right to update the information at any time without notice.<br />
V1.1 March 2<strong>01</strong>1<br />
<strong>Clipsal</strong> Australia Pty Ltd<br />
A member of Schneider Electric<br />
Contact us: clipsal.com/feedback<br />
National Customer Care Enquiries:<br />
Tel 1300 2025 25<br />
Fax 1300 2025 56<br />
clipsal.com<br />
<strong>Clipsal</strong> Australia Pty Ltd reserves the right to change specifications,<br />
modify designs and discontinue items without incurring obligation<br />
and whilst every effort is made to ensure that descriptions,<br />
specifications and other information in this catalogue are correct, no<br />
warranty is given in respect thereof and the company shall not be<br />
liable for any error therein.<br />
© <strong>Clipsal</strong> Australia Pty Ltd. The identified trademarks and copyrights<br />
are the property of <strong>Clipsal</strong> Australia Pty Ltd unless otherwise noted.<br />
<strong>F2338</strong>/<strong>01</strong> CLIPCOM 22795 March 2<strong>01</strong>1