Multileaf collimator S-FD - Siemens
Multileaf collimator S-FD - Siemens
Multileaf collimator S-FD - Siemens
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Datasheet<br />
<strong>Multileaf</strong> <strong>collimator</strong> S-<strong>FD</strong><br />
Answers for life.
<strong>Multileaf</strong> <strong>collimator</strong> S-<strong>FD</strong><br />
Product description<br />
The purpose of the multileaf <strong>collimator</strong> is to precisely<br />
collimate the radiation beam emerging from the X-ray<br />
tube assembly onto the size of the object to be displayed.<br />
This <strong>collimator</strong> is designed for use in mobile surgical<br />
C-arms with flat panel detectors.<br />
It consists of 4 <strong>collimator</strong> levels:<br />
◾ A fixed diaphragm for the max. detector size<br />
◾ A symmetric square diaphragm to limit the size<br />
of the useful field<br />
◾ A symmetric square rotational diaphragm to<br />
compensate for the image rotation (edge clipping)<br />
◾ A slot diaphragm with rotation and free positioning<br />
2<br />
Product features<br />
◾ Designed for flat panel systems<br />
◾ Full remote control via CANopen interface<br />
◾ No inherent filtration<br />
◾ Prepared for the installation of a DAP chamber<br />
Customizing<br />
In order to fulfill your particular requirements, we also<br />
provide you with customized versions of this product.
<strong>Multileaf</strong> <strong>collimator</strong> S-<strong>FD</strong><br />
Ø 88<br />
Ø 176.5<br />
Technical data<br />
Type S-<strong>FD</strong> A<br />
Fixed diaphragm<br />
Quadratic diaphragm:<br />
≥ 28.6 cm ≤ 29.4 cm or 18.2 cm x 18.2 cm (option)<br />
Minimum field size<br />
< 4.1 cm x 4.1 cm<br />
Maximum field size<br />
Rotational square diaphragm:<br />
> 33.1 cm x 33.1 cm<br />
Minimum field size<br />
< 9.1 cm x 9.1 cm<br />
Maximum field size<br />
≥ 33.1 cm x 33.1 cm<br />
Rotation<br />
Slot diaphragm:<br />
Endless<br />
Minimum slot size<br />
< 4.1 cm<br />
Maximum slot size<br />
> 45.4 cm<br />
Rotation<br />
Endless<br />
Radiation shielding<br />
125 kV<br />
Leakage radiation<br />
< 0.7 mGy/h<br />
Collimator power supply 24 VDC (± 10%), max. 4.0 A<br />
Source to flange distance 50 mm<br />
Control interface CANopen DS412<br />
Quality standards<br />
Ambient conditions:<br />
CE, UL, CSA, DHHS<br />
Operating temperature<br />
+ 10° C to + 60° C<br />
Storage temperature<br />
- 40° C to + 70° C<br />
Relative humidity for operation<br />
15% to 75% non-condensing<br />
Relative humidity for storage<br />
≤ 95% non-condensing<br />
Barometric pressure<br />
700 hPa to 1060 hPa<br />
Weight ≤ 3.5 kg<br />
Service Maintenance free<br />
All field sizes are defined for an SID of 100 cm<br />
108<br />
103<br />
18.8°<br />
50<br />
79.8 113.5<br />
90 120<br />
3
The <strong>Siemens</strong> Healthcare Business<br />
Unit Components & Vacuum Technology<br />
is ISO 9001 and ISO 13485<br />
certified, manufactures in accordance<br />
with the Quality System Regulations<br />
(QSR) as defined by the U.S. Food<br />
and Drug Administration (<strong>FD</strong>A) and<br />
endeavors to comply with legal<br />
requirements concerning the environmental<br />
compatibility of its products.<br />
<strong>Siemens</strong> reserves the right to modify<br />
the design and specifications contained<br />
herein without prior notice.<br />
All rights reserved, particularly in<br />
connection with patent applications<br />
or registrations of utility model or<br />
design. This document is not considered<br />
to be a contractual specification.<br />
Kindly contact <strong>Siemens</strong> AG prior<br />
to using this information for equipment<br />
design.<br />
Local Contact Information<br />
<strong>Siemens</strong> AG<br />
Healthcare Sector<br />
H CP CV OEM<br />
Henkestr. 127<br />
DE-91052 Erlangen<br />
Germany<br />
Phone: +49 9131 84-6911<br />
Fax: +49 9131 84-2501<br />
oem.healthcare@siemens.com<br />
Global <strong>Siemens</strong> Headquarters<br />
<strong>Siemens</strong> AG<br />
Wittelsbacherplatz 2<br />
80333 Muenchen<br />
Germany<br />
Global <strong>Siemens</strong> Healthcare<br />
Headquarters<br />
<strong>Siemens</strong> AG<br />
Healthcare Sector<br />
Henkestrasse 127<br />
91052 Erlangen<br />
Germany<br />
Phone: +49 9131 84-0<br />
www.siemens.com/healthcare<br />
Printed in Germany | CC 856 1212 | 10306993_DS_S-<strong>FD</strong> 2012-12 | © 12.2012, <strong>Siemens</strong> AG<br />
www.siemens.com/healthcare<br />
These components and configurations<br />
are not finished medical devices.<br />
Compliance with all laws and regulations<br />
that are applicable to finished<br />
medical devices is the responsibility<br />
of the assembler/manufacturer of the<br />
finished medical device.<br />
The information in this document<br />
contains general descriptions of the<br />
technical options available, which do<br />
not always have to be present in<br />
individual cases. The required features<br />
should therefore be specified in each<br />
individual case at the time of closing<br />
the contract.<br />
Global Business Unit<br />
<strong>Siemens</strong> AG<br />
Medical Solutions<br />
Components and Vacuum Technology<br />
Henkestr. 127<br />
DE-91052 Erlangen<br />
Germany<br />
Phone: +49 9131 84-0<br />
www.siemens.com/oemproducts<br />
The components are labeled as<br />
“Manufactured by <strong>Siemens</strong>”.<br />
However, the buyer shall not market<br />
the components using the “<strong>Siemens</strong>”<br />
brand name and/or trademark. The<br />
buyer may integrate these components<br />
into the medical system using<br />
its own brands and labels. The product<br />
names and/or brands referred to<br />
are the property of their respective<br />
trademark holders.<br />
Legal Manufacturer<br />
<strong>Siemens</strong> AG<br />
Wittelsbacherplatz 2<br />
DE-80333 Muenchen<br />
Germany