Evaluation of the Freus Residential Evaporative Condenser System in PG&E Service Territory<br />
Data, in comma-delimited ASCII format, was downloaded daily to a central computer <strong>and</strong><br />
screened using software to review data quality. Out-of-range data was noted <strong>and</strong> further<br />
investigated visually to determine whether a sensor or monitoring error exists or equipment has<br />
failed. Data review was performed using an EXCEL spreadsheet that allows for loading <strong>and</strong><br />
graphing of all key monitoring parameters in a weekly time series format. Weekly performance<br />
reports were developed for each site <strong>and</strong> emailed to the PG&E project manager. The reports<br />
included plots of temperature, relative humidity, unit power, water consumption, effectiveness,<br />
<strong>and</strong> EER. A sample report is included in Appendix B.<br />
Sensible cooling delivered by the evaporative condenser was determined on a 15 second interval<br />
as shown in Equation 1. Total cooling (sensible plus latent) was also calculated based on the<br />
change in air enthalpy 8 between the return airstream measurement <strong>and</strong> the supply air<br />
measurement (see Appendix B). Historically these enthalpy measurements have not always<br />
produced reasonable results due to sensor accuracy limits <strong>and</strong> the inherent variations in<br />
temperature <strong>and</strong> humidity that occur downstream of an evaporator coil. In this project we<br />
focused on the sensible cooling measurement as the key performance descriptor. For dry<br />
California climates, the impact of ignoring latent is typically small (