Drive. CT series<br />

2.<br />

CT<br />

Ref.1109<br />

20<br />

Starts per hour<br />

By electronic control: unlimited.<br />

By interrupting the AC supply: ≤ 20<br />

Start up time<br />

This is the time taken from the moment of applying power to the drive, to the drive being ready to<br />

run the motor: Its value is 4 s.<br />

Output frequency / speed range ratio<br />

Open-loop frequency range: 0 to 3.000Hz<br />

Closed-loop speed range: From 0 to 40.000 rpm.<br />

Closed-loop frequency range: 0 to 1250 Hz Limited to 600 Hz for best performance.<br />

Acoustic noise<br />

Maximum pressure level at 1m (dBA)<br />

Max. speed Max. speed<br />

SPMD1403 75 43<br />

SPMC1402 53 43<br />

Overall dimensions<br />

H Height including surface mounting brackets<br />

W Width<br />

D Forward panel projection when surface mounted<br />

F Forward panel projection when through-panel mounted<br />

R Rear panel projection when through-panel mounted<br />

SPMD1403<br />

SPMC1402<br />

Approx. mass<br />

H W D F R<br />

795.5 mm<br />

(31.319 in)<br />

399.1 mm<br />

(15.731 in)<br />

310 mm<br />

(12.205 in)<br />

310 mm<br />

(12.205 in)<br />

kg lb<br />

SPMD1403 42 92.6<br />

SPMC1402 20 44<br />

298 mm<br />

(11.732 in)<br />

298 mm<br />

(11.732 in)<br />

202 mm<br />

(7.953 in)<br />

202 mm<br />

(7.953 in)<br />

≤ 95 mm<br />

(3.740 in)<br />

≤ 95 mm<br />

(3.740 in)<br />

Input current, fuse and cable size ratings<br />

The input current is affected by the supply voltage and impedance.<br />

Typical input current. The values of typical input current are given to aid calculations for power<br />

flow and power loss. These values are stated for a balanced supply.<br />

Maximum continuous input current The values of maximum continuous input current are given<br />

to aid the selection of cables and fuses. These values are stated for the worst case condition with<br />

the unusual combination of stiff supply with bad balance. The value stated for the maximum<br />

continuous input current would only be seen in one of the input phases whereas the current in the<br />

other two phases would be significantly lower. The values of maximum input current are stated for<br />

a supply with a 2% negative phase-sequence imbalance and rated at the maximum supply fault<br />

current given in the table.<br />

Supply fault current used to calculate maximum input currents<br />

Symmetrical fault level<br />

SPMD1403 100 kA<br />

SPMC1402 100 kA<br />

Warning. Fuse protection must be provided at the power input.